JJF 1120-2004Calibration specification for thermal ionization isotope mass spectrometers (English PDF)
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJF 1120-2004 in 30 minutes.
Issued by
The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on June 4,.2004, and
Level / Type
National · Mandatory
Issue date
June 4, 2004
Implementation date
September 1, 2004
Scope
JJF 1120-2004 (Calibration specification for thermal ionization isotope mass spectrometers) is available as an English-translated PDF.
JJF 1120-2004 — This standard applies to all the different types of thermal ionization mass spectrometer isotope (hereinafter referred to as mass spectrometer) for calibration.
Found what you need?
Document preview — JJF 1120-2004
National Standard of the People's Republic of China
- Classification
- N 54
Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on June 4,.2004, and
Contents
- 1 Scope (1)
- 2 Citations (1)
- 3 Terms and units of measurement (1)
- 3.1 Isotope abundance (1)
- 3.2 Isotope abundance ratio (1)
- 3.3 Quality range (1)
- 3.4 Resolution (1)
- 3.5 Peak shape factor (1)
- 3.6 System Stability (1)
- 3.7 Sensitivity (ion yield) (1)
- 3.8 Abundance sensitivity (2)
- 3.9 Measurement repeatability (2)
- 3.10 Fractionation effect (2)
- 3.11 Quality Discrimination (2)
- 3.12 Memory Effect (2)
- 4 Overview (2)
- 5 Measurement characteristics (2)
- 6 Calibration conditions (3)
- 6.1 Laboratory Environment (3)
- 6.2 Calibration Equipment (3)
- 6.3 Isotope Reference Materials (3)
- 6.4 Inspection and adjustment of calibration objects (3)
- 7 Calibration items and calibration methods (4)
- 7.1 Resolution Calibration (4)
- 7.2 Sensitivity calibration (5)
- 7.3 Abundance sensitivity calibration (5)
- 7.4 Peak shape coefficient calibration (5)
- 7.5 System Stability Calibration (6)
- 7.6 Internal Repeatability Calibration (6)
- 7.7 External Repeatability Calibration (7)
- 8 Expression of calibration results (8)
- 9 Re-study interval (8)
- Appendix A Calibration Record Format (9)
- Appendix B Thermal Ionization Isotope Mass Spectrometer Calibration Certificate Format (11)
1 Scope (1)
2 Citations (1)
3 Terms and units of measurement (1)
3.1 Isotope abundance (1)
3.2 Isotope abundance ratio (1)
3.3 Quality range (1)
3.4 Resolution (1)
3.5 Peak shape factor (1)
3.6 System Stability (1)
3.7 Sensitivity (ion yield) (1)
3.8 Abundance sensitivity (2)
3.9 Measurement repeatability (2)
3.10 Fractionation effect (2)
3.11 Quality Discrimination (2)
3.12 Memory Effect (2)
4 Overview (2)
5 Measurement characteristics (2)
6 Calibration conditions (3)
6.1 Laboratory Environment (3)
6.2 Calibration Equipment (3)
6.3 Isotope Reference Materials (3)
6.4 Inspection and adjustment of calibration objects (3)
7 Calibration items and calibration methods (4)
7.1 Resolution Calibration (4)
7.2 Sensitivity calibration (5)
7.3 Abundance sensitivity calibration (5)
7.4 Peak shape coefficient calibration (5)
7.5 System Stability Calibration (6)
7.6 Internal Repeatability Calibration (6)
7.7 External Repeatability Calibration (7)
8 Expression of calibration results (8)
9 Re-study interval (8)
Appendix A Calibration Record Format (9)
Appendix B Thermal Ionization Isotope Mass Spectrometer Calibration Certificate Format (11)
Thermal ionization isotope mass spectrometer calibration specification
1 Scope
This specification applies to the calibration of various types of thermal ionization isotope mass spectrometers (hereinafter referred to as mass spectrometers).
2 Citations
JJF 1001-1998 General measurement terms and definitions JJF 1059-1999 Measurement Uncertainty Evaluation and Representation GB/T 15481-2000 General requirements for testing and calibration laboratory capabilities Use of this specification should be done with the current valid version of the above cited documents.
3 terms and units of measure
3.1 Isotope abundance the atomic share of the various isotopes possessed by an element in the element. Isotope abundance representation There are. (1) atomic fraction. the number of moles of a certain stable isotope and the total number of moles of the element Ratio; (2) atomic percentage. the atomic fraction expressed in percentage.
3.2 Isotope abundance ratio the ratio of the isotopic abundance of an element to the other isotopic abundance of that element.
3.3 Quality range
The mass range represents the interval from the smallest to the largest mass of the sample that can be measured by the mass spectrometer. The unit is the atomic mass list.
Bit u.
3.4 resolution
Resolution Characterization The ability of a mass spectrometer to identify two adjacent mass ion beams, defined as being within the mass range of the mass spectrometer the degree to which a particular mass M position is separated from the two ion beams at the M deltaM position and expressed in M/deltaM the resolution of the meter. Dimensionless.
3.5 peak shape factor the peak shape factor characterizes the ion beam imaging characteristics, it is associated with the entrance and exit slits of the mass spectrometer, and the ion optics field shape it is closely related to the structure of the analyzer. Dimensionless.
3.6 System Stability System stability characterizes the stability of the mass spectrometer power supply system, which is measured by the stability of the ion beam. main Dependent on the ion source's accelerating voltage, magnetic field strength and stability of the sample strip, ionization strap supply current, and mass spectrometer the resolution is closely related and dimensionless.
3.7 Sensitivity (ion yield) Sensitivity characterizes the conversion efficiency of atoms (or molecules) with atomic ions (or molecular ions). Mass spectrometer when the receiver detects an isotope ion of an element, the number of atoms of the isotope to be introduced in the ion source.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
Referenced standards
How to Download JJF 1120-2004
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1120-2004
$205.00