Valid

JJF 1116-2004Calibration Specification for Linear Accelerometer Used Precision Centrifuger (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for JJF 1116-2004 in 30 minutes.

Issued by

The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 2,.2004, and

Level / Type

National · Mandatory

Issue date

March 2, 2004

Implementation date

June 2, 2004

Scope

JJF 1116-2004 (Calibration Specification for Linear Accelerometer Used Precision Centrifuger) is available as an English-translated PDF.

JJF 1116-2004 — This standard applies to linear accelerometer calibration precision centrifuge.

Found what you need?

Document preview — JJF 1116-2004

National Standard of the People's Republic of China

ICS
17.160
Classification
A 53

Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 2,.2004, and

Contents

  • 1 Scope (1)
  • 1.1 Subject Contents (1)
  • 1.2 Scope of application (1)
  • 2 Citations (1)
  • 3 Terms (1)
  • 3.1 Precision Centrifuge (hereinafter referred to as centrifuge) acceleration standard (1)
  • 3.2 Line accelerometer (hereinafter referred to as accelerometer) (1)
  • 3.3 Accelerometer Centrifuge Calibration (1)
  • 3.4 Centrifuge working radius (1)
  • 4 Overview (1)
  • 4.1 Working principle of variable resistance accelerometer (1)
  • 4.2 Working principle of variable capacitance (sensing) accelerometer (2)
  • 4.3 Working principle of servo accelerometer (2)
  • 4.4 Resonant accelerometer (2)
  • 5 Measurement characteristics (2)
  • 5.1 Static model equation of accelerometer (2)
  • 5.2 Determine the working radius of the centrifuge (3)
  • 5.3 Measurement range of the accelerometer (4)
  • 5.4 Uncertainty of the accelerometer (4)
  • 5.5 Output form of the accelerometer (4)
  • 6 Calibration conditions (4)
  • 6.1 Basic conditions of the accelerometer (4)
  • 6.2 Environmental conditions (5)
  • 6.3 Requirements for Accelerometers (5)
  • 6.4 Installation of Accelerometers (5)
  • 7 Calibration items and calibration methods (6)
  • 8 Calibration result expression (11)
  • 9 Re-study interval (12)
  • Appendix A Determining the Mathematical Model and Uncertainty Analysis of the Accelerometer Under Test by Least Squares (13)
  • Appendix B Grubbs Guidelines (15)

1 Scope (1)

1.1 Subject Contents (1)

1.2 Scope of application (1)

2 Citations (1)

3 Terms (1)

3.1 Precision Centrifuge (hereinafter referred to as centrifuge) acceleration standard (1)

3.2 Line accelerometer (hereinafter referred to as accelerometer) (1)

3.3 Accelerometer Centrifuge Calibration (1)

3.4 Centrifuge working radius (1)

4 Overview (1)

4.1 Working principle of variable resistance accelerometer (1)

4.2 Working principle of variable capacitance (sensing) accelerometer (2)

4.3 Working principle of servo accelerometer (2)

4.4 Resonant accelerometer (2)

5 Measurement characteristics (2)

5.1 Static model equation of accelerometer (2)

5.2 Determine the working radius of the centrifuge (3)

5.3 Measurement range of the accelerometer (4)

5.4 Uncertainty of the accelerometer (4)

5.5 Output form of the accelerometer (4)

6 Calibration conditions (4)

6.1 Basic conditions of the accelerometer (4)

6.2 Environmental conditions (5)

6.3 Requirements for Accelerometers (5)

6.4 Installation of Accelerometers (5)

7 Calibration items and calibration methods (6)

8 Calibration result expression (11)

9 Re-study interval (12)

Appendix A Determining the Mathematical Model and Uncertainty Analysis of the Accelerometer Under Test by Least Squares (13)

Appendix B Grubbs Guidelines (15)

Precision Accelerator Calibration Specifications for Line Accelerometers

1 Scope

1.1 Subject content

This specification specifies the calibration method for the main technical requirements for calibrating line accelerometers using precision centrifuges.

1.2 Scope of application this specification applies to the calibration of precision centrifuges for line accelerometers.

2 Citations

GJB1037-1990 Single-axis pendulum servo line accelerometer test method GJB1081-1993 Main performance test method for inertial technology test equipment GB/T 2298-1991 Mechanical vibration and shock terminology GJB151A-1997 Electromagnetic emission and sensitivity requirements for military equipment and sub-systems GJB152A-1997 Electromagnetic emission and sensitivity measurement for military equipment and sub-systems GJB585A-1998 Inertial Technical Terminology 3 terms

3.1 Precision Centrifuge (hereinafter referred to as centrifuge) acceleration standard Using the Newtonian mechanics principle, the standard centripetal acceleration is generated by angular motion to calibrate the standard of the line accelerometer Device.

3.2 Line accelerometer (hereinafter referred to as accelerometer) A measuring instrument for measuring constant line acceleration using the principle of inertial measurement.

3.3 Accelerometer Centrifuge Calibration Under the specified conditions, in order to determine the static output acceleration value of the accelerometer, and the corresponding acceleration sign by the centrifuge A set of operations that are related to the relationship between the centripetal acceleration values.

3.4 Centrifuge working radius the distance from the average center of rotation of the centrifuge to the center of mass of the accelerometer.

4 Overview

The mechanical model of a general accelerometer is approximated by a typical mass spring damping system type second-order mechanical model.

Mx'' cx' kx=f (x)

Where. m, c, k --- equivalent detection quality, damping, stiffness;

x'', x', x—the acceleration, velocity, and displacement acting on the equivalent detection quality;

f (x)---external force.

Typical accelerometers can be classified into variable resistance, variable capacitance (sensing), servo, and resonant accelerometers.

4.1 Working principle of variable resistance accelerometer

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

How to Download JJF 1116-2004

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1116-2004

$265.00