Valid

JJF 1111-2003Calibration Specification for Modulation Meters (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for JJF 1111-2003 in 30 minutes.

Issued by

The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on November 24,.2003, and

Level / Type

National · Mandatory

Issue date

November 24, 2003

Implementation date

February 24, 2004

Scope

JJF 1111-2003 (Calibration Specification for Modulation Meters) is available as an English-translated PDF.

JJF 1111-2003 — This standard applies to modulation measurement instrument calibration.

Found what you need?

Document preview — JJF 1111-2003

National Standard of the People's Republic of China

Classification
A 56
Replacing
JJG 437-1989

Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on November 24,.2003, and

Contents

  • 1 Scope (1)
  • 2 Citations (1)
  • 3 Overview (1)
  • 4 Measurement characteristics (1)
  • 4.1 FM frequency offset measurement (1)
  • 4.2 Adjustment amplitude measurement (2)
  • 4.3 Phase shift phase shift measurement (2)
  • 4.4 Residual frequency modulation (2)
  • 4.5 Remaining amplitude modulation (2)
  • 4.6 Remaining phase modulation (2)
  • 4.7 AM suppression during FM measurement (2)
  • 4.8 Frequency modulation suppression during amplitude modulation measurement (2)
  • 4.9 Amplitude modulation suppression during phase modulation measurement (2)
  • 4.10 Demodulation output distortion during FM measurement (2)
  • 4.11 Demodulation output distortion during amplitude modulation measurement (3)
  • 4.12 Demodulation output distortion during phase modulation measurement (3)
  • 5 Calibration conditions (3)
  • 5.1 Environmental conditions (3)
  • 5.2 Standards and other equipment for calibration (3)
  • 6 Calibration items and calibration methods (4)
  • 6.1 Appearance and normality check (4)
  • 6.2 Calibration of FM frequency offset measurement (4)
  • 6.3 Calibration of amplitude measurement (5)
  • 6.4 Calibration of phase shift phase shift measurement (5)
  • 6.5 Measurement of residual frequency modulation (6)
  • 6.6 Measurement of residual amplitude modulation (7)
  • 6.7 Measurement of residual phase modulation (7)
  • 6.8 Measurement of amplitude modulation suppression during frequency modulation measurement (7)
  • 6.9 Measurement of frequency modulation suppression during amplitude modulation measurement (8)
  • 6.10 Calibration of amplitude modulation suppression during phase modulation measurement (8)
  • 6.11 Measurement of Demodulation Output Distortion during FM Measurement (9)
  • 6.12 Measurement of Demodulation Output Distortion during AM Measurement (9)
  • 6.13 Measurement of Demodulation Output Distortion during Phase Modulation Measurement (9)
  • 7 Expression of calibration results (9)
  • 8 Re-study interval (10)
  • Appendix A Calibration Record Format (11)
  • Appendix B Example of Uncertainty Analysis of Measurement Results of Major Projects (18)

1 Scope (1)

2 Citations (1)

3 Overview (1)

4 Measurement characteristics (1)

4.1 FM frequency offset measurement (1)

4.2 Adjustment amplitude measurement (2)

4.3 Phase shift phase shift measurement (2)

4.4 Residual frequency modulation (2)

4.5 Remaining amplitude modulation (2)

4.6 Remaining phase modulation (2)

4.7 AM suppression during FM measurement (2)

4.8 Frequency modulation suppression during amplitude modulation measurement (2)

4.9 Amplitude modulation suppression during phase modulation measurement (2)

4.10 Demodulation output distortion during FM measurement (2)

4.11 Demodulation output distortion during amplitude modulation measurement (3)

4.12 Demodulation output distortion during phase modulation measurement (3)

5 Calibration conditions (3)

5.1 Environmental conditions (3)

5.2 Standards and other equipment for calibration (3)

6 Calibration items and calibration methods (4)

6.1 Appearance and normality check (4)

6.2 Calibration of FM frequency offset measurement (4)

6.3 Calibration of amplitude measurement (5)

6.4 Calibration of phase shift phase shift measurement (5)

6.5 Measurement of residual frequency modulation (6)

6.6 Measurement of residual amplitude modulation (7)

6.7 Measurement of residual phase modulation (7)

6.8 Measurement of amplitude modulation suppression during frequency modulation measurement (7)

6.9 Measurement of frequency modulation suppression during amplitude modulation measurement (8)

6.10 Calibration of amplitude modulation suppression during phase modulation measurement (8)

6.11 Measurement of Demodulation Output Distortion during FM Measurement (9)

6.12 Measurement of Demodulation Output Distortion during AM Measurement (9)

6.13 Measurement of Demodulation Output Distortion during Phase Modulation Measurement (9)

7 Expression of calibration results (9)

8 Re-study interval (10)

Appendix A Calibration Record Format (11)

Appendix B Example of Uncertainty Analysis of Measurement Results of Major Projects (18)

Modulation gauge calibration specification

1 Scope

This calibration specification applies to the calibration of a modulation meter.

2 Citations

JJF 1059-1999 "Measurement and Expression of Measurement Uncertainty".

3 Overview

The modulation meter is used to measure the modulation parameters of the RF modulated signal. Modulation parameters include the most FM signal Large frequency offset (referred to as frequency offset), modulation depth of amplitude modulation signal (referred to as amplitude modulation) and maximum phase of phase modulation signal Offset (referred to as phase shift) and modulation distortion. The common modulation measuring instrument consists of five parts. high frequency amplification and decay Subtraction, local oscillator and mixing, IF amplification, detection (frequency discrimination, envelope detection, etc.) and display, as shown in Figure 1. Due to inspection the wave method is different, and the measurement results are different. There are three types of peaks, RMS and average. Sinusoidal modulation when the peak value is twice the effective value, the effective value is the average value of pi24.

Times. Commonly used detection method is peak value, measurement result Also expressed as a peak. In residual frequency (or amplitude modulation, or phase modulation) measurements, rms detection and rms are typically used.

Said.

figure 1

4 Measurement characteristics

4.1 FM frequency offset measurement Carrier frequency range. (0.15~1300)MHz Modulation frequency range. (0.02~200) kHz Frequency offset measurement range. (0.1~400) kHz Frequency offset measurement tolerance limit. ±3%

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

How to Download JJF 1111-2003

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1111-2003

$654.00