JJF 1088-2015Calibration Specification for Large Dimension Outside Micrometers (English PDF)
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for JJF 1088-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
August 24, 2015
Implementation date
February 24, 2016
Scope
JJF 1088-2015 (Calibration Specification for Large Dimension Outside Micrometers) is available as an English-translated PDF.
JJF 1088-2015 — This standard applies to the calibration value of 0.01mm, the measurement range is (500 ~ 1000) mm, (1000 ~ 3000) mm large diameter micrometer calibration.
Found what you need?
Document preview — JJF 1088-2015
National Standard of the People's Republic of China
- ICS
- 17.04
- Classification
- A 52
- Replacing
- JJF 1088-2002
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (III)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 4 Metrological characteristics (2)
- 4.1 Anvil surface and measuring the relative offsets micrometer screw measuring surface (2)
- 4.2 Load and load change (2)
- 4.3 Differential cylinder tapered end surface edge to the distance scale marks fixed casing surface (2)
- 4.4 Relative positional differential cylinder end face of the fixed cone sleeve millimeter scale marks (2)
- 4.5 Measuring surface roughness of the surface (3)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Metrological characteristics (2)
4.1 Anvil surface and measuring the relative offsets micrometer screw measuring surface (2)
4.2 Load and load change (2)
4.3 differential cylinder tapered end surface edge to the distance scale marks fixed casing surface (2) 4.4 relative positional differential cylinder end face of the fixed cone sleeve millimeter scale marks (2)
4.5 Measuring surface roughness of the surface (3)
Anvil and the flatness of 4.6 micrometer screw measuring surface (3)
4.7 Two measuring surface Parallelism (3)
Indication error of 4.8 micrometer head (4) Large 4.9 micrometer diameter indication error (4) Return error indicator 4.10 (4)
4.11 The amount of proofreading rod (4) Calibration Condition 5 (4) Environmental conditions 5.1 (4)
5.2 Calibration standards and project control and ancillary equipment (5)
Calibration Method 6 (5)
6.1 Anvil surface and measuring the relative offset (6) micrometer screw measuring surface
6.2 Load and load change (6)
6.3 differential cylinder tapered end surface edge to the distance scale marks fixed casing surface (6) 6.4 relative positional differential cylinder end face of the fixed cone sleeve millimeter scale marks (6)
6.5 Measuring surface roughness of the surface (7)
6.6 Anvil and flatness (7) micrometer screw measuring surface
6.7 Two parallel measuring surface (7)
Indication error of 6.8 micrometer head (7) Large 6.9 micrometer diameter indication error (8) Return error indicator 6.10 (9)
6.11 Proofreading dosage lever (9)
7 Calibration result expression (9)
8 Recalibration interval (9)
APPENDIX A large outside micrometer Measurement Uncertainty about Indication Error Calibration Results Evaluation
(Measuring range 500mm ~ 1000mm) (10) Appendix B Large micrometer diameter Measurement Uncertainty about Indication Error Calibration Results Evaluation (Measuring range 1000mm ~ 3000mm) (14) Appendix C calibration certificate content and in-page format (19) Appendix D proofreading rod size deviation limit the amount of provisions (500mm ~ 1000mm) (21)
Introduction
JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "common terminology and measurement Definitions ", JJF 1059.1-2012" Evaluation and Expression of Uncertainty in Measurement "together constitute the support of the calibration code revision Basic series of normative work.
The code revision, the main reference standard JB/T 10007-2012 "Great outside micrometer (measuring range 1000mm ~ 3000mm) "and GB/T 1216-2004" outside micrometer ", this specification replace JJF 1088-2002 "outside micrometer (measuring range 500mm ~ 3000mm) calibration specification." Compared with JJF 1088-2002, in addition to editorial changes, the main technical specification of the changes are as follows.
--- Name specification to "large outside micrometer calibration specification."
--- Large size outside micrometer overview has been modified.
--- Remove the "radial and axial movement of the micrometer screw swing" and "groove width and a width between" the two index.
--- Increased by gantry measuring "return error indication table" approach jog.
--- Anvil surface and measuring the relative offsets micrometer screw measuring surface index has been modified.
--- Increase with large table outside micrometer anvil activity indicator measuring the force at the contact plane and spherical, and measure Changes within their means giving provisions.
--- Surface roughness measuring surface according to the type of material, the shape of the surface can vary somewhat.
--- For measuring surface flatness index has been modified.
--- Indicators parallelism of two micrometer diameter measuring surface has been modified.
--- Indication error indicators micrometer head has been modified.
--- Large size outside micrometer indicators and calibration method error of indication has been modified.
--- Indicators proofreading amount Rod Size deviation has been modified.
--- Canceled proofing dipstick parallel index requirements.
--- Face of two parallel calibration method were refined.
--- The amount of block size micrometer indication when using error correction were perfect with GB recommended values of unity.
--- Re-measurement of Uncertainty about Indication Error assessed.
JJF 1088 of previously issued as follows.
JJF 1088-2002 "outside micrometer (measuring range 500mm ~ 3000mm) calibration standard" JJG193-1987 micrometer (measuring range 500mm ~ 3000mm) (Trial) Large outside micrometer calibration specification
1 Scope
This instruction applies to indexing is 0.01mm, respectively measuring range (500 ~ 1000) mm, (1000 ~
3000) mm large size micrometer diameter calibration.
2. References
This specification refers to the following documents.
JB/T 10007-2012 large outside micrometer (measuring range 1000mm ~ 3000mm) GB/T 1216 outside micrometer for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 Overview
Large outside micrometer screw vice principle is the use of two measuring foot rack between surfaces separated by distance measurement External dimensions measuring instruments. Anvil can be changed or large size adjustable micrometer diameter shown in Figure 1, with a large table outside micrometer
Figure 2, the amount of proofreading rod in Figure 3.
Figure 1 anvil can be changed or large size adjustable outside micrometer
1- foot frame; 2- anvil; 3- anvil fastening bolts; 4- force measuring device; 5- differential cylinder; 6- fixed casing;
7- spindle locking device; 8- micrometer screw; 9- thermal insulation
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
How to Download JJF 1088-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1088-2015
$524.00