JJF 1087-2002Control of Measurement Processes for Heavy Direct Current (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for JJF 1087-2002 in 30 minutes.

Issued by

The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 13,.2002, and

Level / Type

National · Mandatory

Issue date

September 13, 2002

Implementation date

December 13, 2002

Scope

JJF 1087-2002 (Control of Measurement Processes for Heavy Direct Current) is available as an English-translated PDF.

JJF 1087-2002 — This standard applies to the measurement process electrochemical, electrical and metallurgical industries 1kA to 300kA middleweight DC Current Measurement Systems.

Found what you need?

Document preview — JJF 1087-2002

National Standard of the People's Republic of China

Classification
A 55

Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 13,.2002, and

Contents

  • 1 Scope (1)
  • 2 Citations (1)
  • 3 Terms (1)
  • 4 Overview (4)
  • 5 DC high current measurement process control requirements (4)
  • 6 Metrological performance requirements for DC high current measuring equipment (6)
  • 7 Measurement confirmation of DC high current measuring equipment (7)
  • 7.1 Confirmation of the difference between the working standard and the transmission standard current ratio under laboratory conditions (8)
  • 7.2 Establishing working standard process parameters under laboratory conditions (9)
  • 7.3 Verification of working standard process parameters under field conditions (9)
  • 7.4 Measurement confirmation of single current measuring device for on-site power rectifier equipment (9)
  • 7.5 Measurement confirmation of on-site total measurement system (10)
  • 7.6 Measurement confirmation of total current measuring device (10)
  • 7.7 Establishing the current measurement device operating process parameters (11)
  • 7.8 Establishing the operating parameters of the total current measuring device (12)
  • 7.9 Establishing the running current x--R control chart (12)
  • 7.10 Verification of working standard quantity procedures (13)
  • 8 Monitoring and measurement quality control of current measuring device operation process (14)
  • 9 Measurement confirmation report and record of DC high current measurement system (15)
  • Appendix A DC High Current Measuring Equipment Measurement Confirmation Data Sheet Format (16)
  • Appendix B Schematic diagram of wiring principle of on-site current measurement method and voltage measurement method (18)
  • Appendix C Error Correction Method for Total Measurement System (19)
  • Appendix D DC High Current Measurement System Measurement Confirmation Report Format (20)
  • Appendix E DC High Current Measurement System Working Standard Verification Report Format (22)

1 Scope (1)

2 Citations (1)

3 Terms (1)

4 Overview (4)

5 DC high current measurement process control requirements (4)

6 Metrological performance requirements for DC high current measuring equipment (6)

7 Measurement confirmation of DC high current measuring equipment (7)

7.1 Confirmation of the difference between the working standard and the transmission standard current ratio under laboratory conditions (8)

7.2 Establishing working standard process parameters under laboratory conditions (9)

7.3 Verification of working standard process parameters under field conditions (9)

7.4 Measurement confirmation of single current measuring device for on-site power rectifier equipment (9)

7.5 Measurement confirmation of on-site total measurement system (10)

7.6 Measurement confirmation of total current measuring device (10)

7.7 Establishing the current measurement device operating process parameters (11)

7.8 Establishing the operating parameters of the total current measuring device (12)

7.9 Establishing the running current x--R control chart (12)

7.10 Verification of working standard quantity procedures (13)

8 Monitoring and measurement quality control of current measuring device operation process (14)

9 Measurement confirmation report and record of DC high current measurement system (15)

Appendix A DC High Current Measuring Equipment Measurement Confirmation Data Sheet Format (16)

Appendix B Schematic diagram of wiring principle of on-site current measurement method and voltage measurement method (18)

Appendix C Error Correction Method for Total Measurement System (19)

Appendix D DC High Current Measurement System Measurement Confirmation Report Format (20)

Appendix E DC High Current Measurement System Working Standard Verification Report Format (22)

DC high current measurement process control the accurate measurement of DC large current plays an important role in the production management of electrochemical and electrometallurgical industries. At ISO , in the IEC and China standards, there is no corresponding technical standard and measurement technology for DC high current measuring equipment.

specification. Since there is no uniform standard, the DC current in the electro-chemical and electro-metallurgical industry cannot be accurately and consistently measured.

The economic indicators related to DC power consumption are not comparable, and the technical conditions of electrolytic production processes cannot be optimized, thus reducing electricity.

The utilization rate and economic benefits seriously restrict the progress of production management technology.

Due to DC high current measuring equipment (including measurement standards and current measuring devices) only under laboratory conditions Calibration does not guarantee that the measurement results under field conditions are consistent with the results measured in the laboratory. for Solve the problem that the field DC large current value is not comparable with the laboratory value, according to GB/T 19022.2-

2000 Quality assurance requirements for measuring equipment - Part 2. Guide to measurement process control (idt ISO 10012-2:1997) the measurement process concept, that is, the measurement as a complete process, from the scientific basis of the measurement and measurement the traceability of the quasi-quantity and the start of calibration, as well as the determination of the maximum allowable error of the current measuring device, the measurement confirmation, verification or adjustment, the objective data is presented, and the measurement standard and the measurement given by the current measuring device are finally confirmed.

The results meet the expected usage requirements, and at the same time confirm the DC high current magnitude to the laboratory DC the flow ratio reference standard is traceable, and the magnitude of the current is comparable under different conditions. DC high current measurement the process validation and process control are standardized and managed, so that the measurement quality of the current can be effectively controlled.

1 Scope

This specification is applicable to the measurement of DC high current measurement systems of the order of 1kA to 300kA in the electrochemical and electrometallurgical industries.

Quantity process control.

DC high current measuring device supply and demand sides can refer to this specification for product quality requirements when signing an agreement.

2 Citations

GB/T 19022.1-1994 "Quality assurance requirements for measuring equipment" Part 1 "Measurement of measuring equipment" Recognition system GB/T 19022.2-2000 "Quality Assurance Requirements for Measuring Equipment" Part 2 "Guidelines for Measurement Process Control" JJF 1047-1994 "Magnetic Coupling DC Current Measurement Converter Calibration Specification" JJF 1059-1999 "Measurement and Expression of Measurement Uncertainty" JJF 1001-1998 General Terms and Definitions ISO 8258:1991 "Hugh Hart Control Chart" (English version) GB/T 19000-2000 "Quality Management System" GB/T 18293-2001 "Online measurement of operating efficiency of power rectifier equipment" 3 terms

3.1 Measurement process control controlofmeasurementprocesses

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

How to Download JJF 1087-2002

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1087-2002

$704.00