JJF 1075-2015Calibration Specification for Clamp Ammeters (English PDF)
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for JJF 1075-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
December 7, 2015
Implementation date
June 7, 2016
Scope
JJF 1075-2015 (Calibration Specification for Clamp Ammeters) is available as an English-translated PDF.
JJF 1075-2015 — This standard is applicable to the calibration of a Clamp ammeter with a line voltage of not more than 650 V, a DC or AC frequency of (45 to 400) Hz, and a current of 0.1 to 2 000.
It is also suitable for the calibration of the multifunction clamp current function.
Found what you need?
Document preview — JJF 1075-2015
National Standard of the People's Republic of China
- Classification
- A 55
- Replacing
- JJF 1075-2001
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Overview (1)
- 4 Metering characteristics (1)
- 5 Calibration conditions (1)
- 5.1 Environmental conditions (1)
- 5.2 Measurement standards and other equipment (2)
- 6 Calibration items and calibration methods (3)
- 6.1 Calibration items (3)
- 6.2 Calibration method (3)
- 7 Calibration Results Expression (6)
- 8 Re-school time interval (7)
- Appendix A Clamp Ammeter Current Measurement Uncertainty Evaluation Example (8)
- Appendix B Introduction and Calibration of Clamp Ammeter (11)
- Appendix C Clamp Ammeter Current Maximum Allowable Error Representation (15)
- Appendix D Clamp Ammeter Calibration Original Recording Format (16)
- Appendix E Clamp Ammeter Calibration Certificate Inside Page Format (18)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Metering characteristics (1)
5 Calibration conditions (1)
5.1 Environmental conditions (1)
5.2 Measurement standards and other equipment (2)
6 Calibration items and calibration methods (3)
6.1 Calibration items (3)
6.2 Calibration method (3)
7 Calibration Results Expression (6)
8 Re-school time interval (7)
Appendix A Clamp Ammeter Current Measurement Uncertainty Evaluation Example (8)
Appendix B Introduction and Calibration of Clamp Ammeter (11)
Appendix C Clamp Ammeter Current Maximum Allowable Error Representation (15)
Appendix D Clamp Ammeter Calibration Original Recording Format (16)
Appendix E Clamp Ammeter Calibration Certificate Inside Page Format (18)
Introduction
This specification is based on JJF 1071-2010 "National Metrological Calibration Rules", JJF 1059.1-2012 "Measurement Uncertainty Assessment and Representation", JJF 1001-2011 "Generic Metrological Terms and Definitions".
This specification is a revision of the JJF 1075-2001 "Clamp Ammeter Calibration Specification".
Compared with JJF 1075-2001, the main amendments are.
- the preparation of the format in line with JJF 1071-2010 "national measurement calibration rules to prepare the rules" requirements;
--- The scope of application has been adjusted. The operating frequency range of the clamp ammeter is adjusted to DC or (45 ~
400) Hz;
--- to expand the current measurement range, from the original (0.1 ~ 1000) A expanded to (0.1 ~.2000) A;
--- to calibrate the accuracy of the school level to 0.2;
- for the expansion of the uncertainty of the k value of the re-provision, provides k = 2;
- The calibration method is re-divided into four methods. 1) standard current source method; 2) standard table ratio More law; 3) standard transformer method; 4) standard resistance method;
- Appendix A adds an example of the uncertainty of the current measurement of the clamp ammeter;
--- Appendix B to increase the clamp ammeter calibration methods introduced and error analysis;
- Appendix C increases the maximum allowable error representation of the clamp ammeter current;
--- Appendix D, E Added Clamp Ammeter Calibration Original Record/Calibration Certificate Inside Page Format.
The previous release of this specification is.
--- JJF 1075-2001.
Clamp ammeter calibration specification
1 Scope
This specification applies to line voltage not exceeding 650V, DC or AC frequency is (45 ~ 400) Hz, current (0.1 ~.2000) A clamp ammeter calibration, but also for multi-function clamp meter current function calibration. Not applicable Calibration of the clamp leakage ammeter.
2 reference file
This specification refers to the following documents.
Current Meter, Voltmeter, Power Meter and Resistance Meter JB/T 9285-1999 Clamp ammeter for dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.
3 Overview
Clamp ammeter (including digital, pointer) is a way to open and close the magnetic circuit in the current conductor to measure its electrical Flow of the instrument. It is characterized by no need to disconnect the loop, you can measure the current measured circuit. In accordance with the principle of measurement clamp Ammeter can be divided into transformer, Hall effect and magnetic balance and so on.
The principle of the transformer clamp ammeter can only measure the AC current, Hall effect principle and the principle of magnetic balance of the clamp Flow meter can measure AC and DC current.
4 measurement characteristics Current.
Measuring range. (0.1 ~.2000) A;
Operating frequency. DC or AC frequency (45 ~ 400) Hz;
The maximum allowable error is shown in Table 1, where the error of the digital clamp ammeter is expressed by relative error, the pointer clamp the ammeter error is expressed as a reference error. The error representation is given in Appendix C.
Table 1 clamp ammeter maximum allowable error
Accuracy class 0.2 grade 0.5 grade 1.0 grade 2.0 grade 5.0 Maximum permissible error ± 0.2% ± 0.5% ± 1.0% ± 2.0% ± 5.0% Note. The above indicators are not used for qualifying, for reference only.
5 calibration conditions
5.1 Environmental conditions Ambient temperature. (20 ± 5) °C;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
How to Download JJF 1075-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1075-2015
$519.00