JG/T 231-2018Technical requirements of building glass skylight system (English PDF)
Also coversJGT231-2018
This is a limited preview
Buy now to download the full PDF (33 pages)
Need quotation for your management?
Get a formal quotation for JG/T 231-2018 in 30 minutes.
Issued by
Ministry of Housing and Urban-Rural Development of the People's Republic of China
Level / Type
National · Recommended
Issue date
June 26, 2018
Implementation date
December 1, 2018
Scope
JG/T 231-2018 (Technical requirements of building glass skylight system) is available as an English-translated PDF.
JG/T 231-2018 is the Chinese standard "Technical requirements of building glass skylight system". Its scope clause reads: This Standard specifies the terms and definitions, classification and marks, general requirements, materials and components, production and assembly requirements, requirements and test methods.
This Standard is applicable to building glass skylight system. Its clauses include terms and definitions; classification and marks; general requirements; materials and components; production and assembly requirements; requirements; test methods.
It was issued by the Ministry of Housing and Urban-Rural Development of the People's Republic of China on 2018-06-26 and took effect on 2018-12-01.
Found what you need?
Document preview — JG/T 231-2018
National Standard of the People's Republic of China
- ICS
- 91.060.20
- Classification
- P 32
Issued by: Ministry of Housing and Urban-Rural Development of the People's Republic of China
Contents
- Foreword...3
- 1 Scope...5
- 2 Normative references...5
- 3 Terms and definitions...8
- Annex A (informative) Detection limit of different matrix specimens...33
1 Scope
This Standard specifies the terms and definitions, classification and marks, general requirements, materials and components, production and assembly requirements, requirements and test methods.
This Standard is applicable to building glass skylight system.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 2680, Determination of light transmittance, solar direct transmittance, total solar energy transmittance and ultraviolet transmittance for glass in building and related glazing factors
GB/T 4171, Atmospheric corrosion resisting structural steel
GB/T 5117, Covered electrodes for manual metal arc welding of non-alloy and fine grain steels
GB/T 5118, Covered electrodes for manual metal arc welding of creep- resisting steels
GB/T 5224, Steel strand for prestressed concrete
GB/T 5237 (all parts), Wrought aluminium alloy extruded profiles for architecture
GB/T 8485, The graduation and test for airborne sound insulating properties of windows and doors
GB 8624, Classification for burning behavior of building materials and products
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 building glass skylight system glass skylight system for short
4 Classification and marks
4.1 Classification
4.1.1 According to the supporting structure, it can be divided into steel structure (G), cable rod structure (S), aluminum alloy structure (L), glass beam structure (B).
4.2 Marks
4.2.1 Marking method
The mark is composed of the product code of the glass skylight system (CGD), standard code, support structure category code, opening-closing category code, closed category code, and main parameters (structural performance).
4.2.2 Marking example
Example. CGD-S-K-FB/3.5-JG/T231, which represents a closed glass skylight system that is supported by cable rod structure, is openable, the structural performance is 3.5kPa and complies with the industrial standard JG/T 231.
5 General requirements
5.1 The materials used for glass skylight system shall meet the relevant regulations of the current national standards, see Annex A. There shall be exit- factory certificate and quality certificate.
5.3 The area of glass panel used for glass skylight system shall not exceed
2.5m2.The length of the long side shall not be greater than 2m.
5.7 The energy-saving design of glass skylight system shall comply with the requirements of GB 50176, GB 50189, JGJ 26, JGJ 75 and JGJ 134.
5.8 The durability of glass skylight system, anti-condensation (frost, ice) and
hail resistance shall meet the design requirements.
5.15 The visible light transmittance of glass skylight system shall meet the lighting design requirements. A glass panel with visible light reflectance not greater than 0.30 is preferred.
6 Materials and components
6.1 Aluminum alloy profile
6.1.1 The base material of aluminum alloy profile shall meet the requirements of GB/T 5237.1.The allowable size deviation shall meet the requirements of high precision or ultra-high precision.
6.1.2 When aluminum alloy profiles using anodizing, electrophoretic painting, powder spraying, fluorocarbon paint spraying for surface treatment, it shall respectively comply with the requirements of GB/T 5237.2, GB/T 5237.3, GB/T
5237.4, and GB/T 5237.5.The thickness of the surface treatment layer shall meet the requirements of Table 1.
6.3 Pull rod
6.3.1 Steel ropes for glass skylight system shall use steel strands. The nominal diameter of the steel strand of the main load steel rope shall not be less than
12mm and shall meet the design requirements.
6.3.2 Zinc-5% aluminum-mixed rare earth alloy coated steel strands shall meet the requirements of GB/T 20492.Other steel strands shall meet the requirements of GB/T 5224.Stainless steel strands shall meet the requirements of GB/T 25821 and JG/T 200.
6.4.4 In addition to the requirements of 6.4.3 of this Standard and GB/T 11944, the laminated insulating glass for glass skylight system shall also meet the following requirements.
6.4.6 The glass for photovoltaic glass skylight system shall meet the requirements of JGJ 113.
6.5 Hardware
6.5.1 The hardware for glass skylight system shall comply with the relevant national standards. See Annex A for common material standards.
6.5.2 In addition to stainless steel, hardware for glass skylight system shall be anti-corrosive.
6.5.3 The bearing capacity and service life of the hardware shall meet the design requirements. Check the bearing capacity of main stressed hardware.
6.6 Sealing material
6.9 Other materials
6.9.1 Padding material for the top joints of glass skylight system shall use polyethylene foam stick. The density shall not be greater than 37kg/m3.
6.9.2 Graduation of combustion performance of insulation materials for glass
skylight system shall comply with relevant requirements of GB 8624.Non- combustible or flame-retardant materials such as rock wool, mineral wool, glass wool shall be used.
7 Production and assembly requirements
7.1 Glass production requirements
7.1.1 The size and allowable deviation of rectangular tempered glass shall meet the requirements of Table 2.
feeler
7.1.3 The size and allowable deviation of rectangular insulating glass panels
shall meet the requirements of Table 4.
7.1.4 The size and allowable deviation of triangle, rhombus, parallelogram, trapezoid, round panels shall meet the requirements of Table 5.
7.3.1.3 Components shall meet design requirements. The allowable deviation of component assembly shall meet the requirements of Table 12.
7.3.2 Cable rod structure
The appearance of the steel cable shall meet the design requirements, without rust spots on the surface. Steel strands shall not have broken wires or other obvious mechanical damage. The stainless-steel strands for cable structure shall meet the relevant requirements of GB/T 25821 and JG/T 200.The allowable deviation of the processing of cable components shall meet the requirements of Table 13.
8 Requirements
8.1 Structural performance
8.1.1 Structural performance of glass skylight system shall include possible wind load, stagnant load, snow load, ice load, sunshade device and lighting device loads, live loads and other loads. Combine the various loads and effects on the glass skylight system in a direction perpendicular to the glass skylight system according to GB 50009 and GB 50011.Take the combined load standard value under the most unfavorable conditions as the performance indicator of the glass skylight system.
8.6 Photothermal performance
The photothermal performance of glass skylight system is expressed by light- to-heat ratio (r or LSG). The graduation shall meet the requirements of Table
23.
8.7 Thermal cycling performance
8.7.1 There shall be no condensation on the test piece during the thermal cycling test, without dysfunction or damage.
8.7.2 The thermal cycling performance of glass skylight system shall meet the following requirements.
9 Test methods
9.1 Structural performance
The structural performance testing of glass skylight system shall be performed in accordance with GB/T 34555.
9.4 Insulation performance
The insulation performance testing of glass skylight system shall be performed in accordance with GB/T 29043.When testing, the test piece shall be installed at the actual angle. The insulation performance can also be calculated according to the method specified by JGJ/T 151.
9.6 Photothermal performance
9.6.1 The measurement of visible light transmittance shall be performed in accordance with GB/T 2680.Visible light transmittance of glass skylight system can be calculated according to JGJ/T 151.
9.7 Thermal cycling performance
Thermal cycling performance of glass skylight system can be implemented according to JG/T 397.When testing, the test piece shall be installed at the actual angle.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 33 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2680Glass in building—Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
- GB/T 4171Atmospheric corrosion resisting structural steel
- GB/T 5224Steel strand for prestressed concrete
- GB/T 8485The graduation and test for airborne sound insulating properties of windows and doors
- GB 8624Classification for burning behavior of building materials and products
GB/T 5117 · GB/T 5118 · GB/T 5237
How to Download JG/T 231-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 8624-2025 — Classification for burning behavior of building materials and products
GB/T 2680-2021 — Glass in building—Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
GB/T 26800-2011 — Conduction electrodes
Secure payment via Stripe
Payments accepted
JG/T 231-2018
$265.00