Scope

JB/T 11049-2010 is the English-translated version of 自力式压力调节阀.

JB/T 11049-2010 is the Chinese standard "Self-operated pressure regulating valves".

Its scope clause reads: This standard specifies the product classification and basic parameters, requirements, test methods, inspection rules, as well as marking, packaging and storage of self-operated pressure regulator (hereinafter referred to as the "pressure regulator").

It is applicable to pressure regulators consisting of valves and actuators for measurement and control in industrial processes. It is not applicable to pressure regulators subjected to radioactive operating conditions and other hazardous operating conditions. Its clauses include terms and definitions.

Found what you need?

Document preview — JB/T 11049-2010

National Standard of the People's Republic of China

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Foreword i
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Product classification and basic parameters
  • 4.1 Product classification
  • 4.2 Basic parameters
  • 4.3 Operating conditions
  • 5 Requirements
  • 5.1 Setting pressure range
  • 5.2 Pressure load characteristic
  • 5.3 Flow load characteristic
  • 5.4 Opening pressure error
  • 5.5 Difference of pressure
  • 5.6 Tightness of packing box and other connections
  • 5.7 Tightness of air chamber
  • 5.8 Compressive strength
  • 5.9 Leakage
  • 5.10 Rated flow coefficient
  • 5.11 Resistance to operating vibration
  • 5.12 Action life
  • 5.13 Appearance
  • 6 Test methods
  • 6.1 Test conditions and description
  • 6.2 Setting pressure range
  • 6.3 Pressure load characteristic
  • 6.4 Flow load characteristic
  • 6.5 Opening pressure error
  • 6.6 Difference of pressure
  • 6.7 Tightness of packing box and connections
  • 6.8 Tightness of air chamber
  • 7 Inspection rules
  • 8 Marking, packaging and storage
  • Bibliography
  • Figure 1 Schematic diagram of test devices for pressure and flow load characteristic tests
  • Figure 2 Schematic diagram of test devices for tests on opening pressure error and difference of pressure
  • .detail td {

1 Scope

This standard specifies the product classification and basic parameters, requirements, test methods, inspection rules, as well as marking, packaging and storage of self-operated pressure regulator (hereinafter referred to as the "pressure regulator").

It is applicable to pressure regulators consisting of valves and actuators for measurement and control in industrial processes.

It is not applicable to pressure regulators subjected to radioactive operating conditions and other hazardous operating conditions.

2 Normative references

The following documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments (excluding corrections) to, or revisions of, any of these publications do not apply to this standard. However parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition applies.

GB/T 4213-2008 Pneumatic industrial process control valves

GB/T 13384-2008 General specifications for packing of mechanical and electrical product

JB/T 8218 Terms for final controlling element

3 Terms and definitions

For the purposes of this document, the terms and definitions given in JB/T 8218, as well as the following apply.

3.1 pressure-to-close action

action mode by which the valve interceptor tends to close with the increased setting pressure (difference of pressure)

3.2 pressure-to-open action

action mode by which the valve interceptor tends to open with the increased setting pressure (difference of pressure)

3.3 pipe with pressure tap

pipe fitting connected with the process pipe and the body of pressure regulator, with pressure tap set on the pipe wall for releasing fluid pressure

Note: Generally, the pressure tap is a round hole, its axis is perpendicular to the pipe axis, and the edge is sharp but without spikes.

3.4 control line

pressure guiding pipe fittings connected to the actuator

3.5 condensation chamber

container used to isolate high-temperature controlled media from entering the actuator directly

3.6 pressure load characteristic

deviation of the downstream setting pressure caused by the change of upstream pressure in specified range under the condition of constant output flow, which is generally expressed in a percentage of the setting pressure

3.7 flow load characteristic

deviation of the downstream setting pressure caused by the change of downstream output flow in specified range under the condition of specified upstream pressure, which is generally expressed in a percentage of the setting pressure

3.8 setting pressure

target pressure of the pressure regulator when it is working normally. The setting pressure of the pressure-to-open regulator may be called the setting opening pressure (in MPa)

3.9 setting pressure range

target pressure range of the pressure regulator, which may be adjusted by the set spring […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download JB/T 11049-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JB/T 11049-2010

$354.00