HS/T 50-2016Quantitative analysis of the aromatics in hydrocarbons (English PDF)
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for HS/T 50-2016 in 30 minutes.
Issued by
General Administration of Customs of PRC
Level / Type
National · Recommended
Issue date
February 29, 2016
Implementation date
March 1, 2016
Scope
HS/T 50-2016 (Quantitative analysis of the aromatics in hydrocarbons) is available as an English-translated PDF.
HS/T 50-2016 — This standard specifies the instruments and equipment for testing the aromatic content in hydrocarbons, determination procedures and processing of analysis results.
Found what you need?
Document preview — HS/T 50-2016
National Standard of the People's Republic of China
- ICS
- 71.040
- Classification
- E 30
Issued by: General Administration of Customs of PRC
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Principles...4
- 4 Equipment...4
- 5 Measurement steps...5
- 6 Analytical results...6
- 7 Results representations...6
- Appendix A (Informative)...8
- Appendix B (Normative)...11
- Appendix C (Normative)...12
- References...13
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009,
HS/T 1-2011 and HS/T 39-2013.
This standard uses the redrafting method to modify and adopt U0P 744-06 "Gas
Chromatographic Determination of Aromatics in Hydrocarbons".
The technical differences between this standard and UOP 744-06 and the
reasons are as follows.
- MODIFY the scope of application, to be applied to the determination of
hydrocarbons containing aromatic hydrocarbons whose final boiling point
is not higher than 285 °C, so as to clarify the scope of testing products;
- ADD the use of gas chromatography-mass spectrometry, for qualitative
analysis of each component, to meet the technical requirements of customs
supervision and taxation;
- Considering the complex composition of mixed aromatics, the correction
factor of the peak area in this standard is calculated by the effective carbon
number theory instead of the method of preparing the calibration solution,
to simplify the processing steps of the experimental results.
This standard has made the following editorial changes.
- In order to be consistent with the content of the existing standard, CHANGE
the standard name to "Quantitative analysis of the aromatics in
hydrocarbons".
This standard was proposed by the Customs Administration Department of the
General Administration of Customs of the People's Republic of China.
This standard shall be under the jurisdiction of the Department of Policies and
Regulations of the General Administration of Customs of the People's Republic
of China.
Drafting organizations of this standard. Shanghai Customs of the People's
Republic of China, China Standard Technical Service (Shanghai) Co., Ltd.
1 Scope
This standard specifies the instruments and equipment for testing the aromatic
content in hydrocarbons, determination procedures and processing of analysis
results.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) is applicable to this standard.
UOP 744-06 Gas Chromatographic Determination of Aromatics in
Hydrocarbons
3 Principles
The samples are injected into a gas chromatograph-mass spectrometer and a
gas chromatograph which is equipped with an FID detector. Each composition
is qualitatively determined by the GC-Mass total ion chromatogram, then
quantified by the GC-FID chromatogram.
4 Equipment
Gas chromatography-mass spectrometer. It is equipped with mass
spectrometer with E1 source, split/splitless sample inlet, autosampler; equipped
with a data processor or chemistry workstation for acquiring and processing
data.
5 Measurement steps
According to the determination conditions in 5.1, take two parallel samples and
run them on GC-FID and GC-MS, respectively. The retention time and
chromatographic peak area of each component are automatically collected by
the chromatographic data processor. According to the GC-MS total ion
chromatogram, confirm the name of each compound on the GC-MD
chromatogram
6 Analytical results
Using the stepwise analysis of variance method, calculate the standard
deviation within the same day according to the average concentration in Table
C.1 in Appendix C. For two tests conducted by the same analyst in a laboratory
on the same day, the difference cannot exceed the allowable deviation under
the 95% confidence level as shown in Table C.1.
7 Results representations
The analysis result requirements are as follows.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
Normative references
UOP 744
How to Download HS/T 50-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
HS/T 85-2024 — General rules for customs tax-related laboratory identification
HS/T 62-2019 — Determination of copper content in printed circuit board waste and scrap -- Wavelength dispersive X-Ray fluorescence spectrometry