HJ 609-2011The Technical Requirement for water Quality Automatic On-line Monitor of Chromium(VI) (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for HJ 609-2011 in 30 minutes.

Issued by

Ministry of Environmental Protection Announcement 2011 No.12

Level / Type

National · Mandatory

Issue date

February 11, 2011

Implementation date

June 1, 2011

Scope

HJ 609-2011 (The Technical Requirement for water Quality Automatic On-line Monitor of Chromium(VI)) is available as an English-translated PDF.

HJ 609-2011 — This Standard specifies the performance, test method and technical requirement for water quality automatic on-line monitor of chromium (VI).

This Standard applies to the production, application selection, and performance test of automatic on-line monitor of chromium compound ion (VI) in surface water, sanitary sewage and industrial waste water.

Found what you need?

Document preview — HJ 609-2011

National Standard of the People's Republic of China

Issued by: Ministry of Environmental Protection Announcement 2011 No.12

Contents

  • Announcement...2
  • Foreword...4
  • 1 Scope...5
  • 2 Normative references...5
  • 3 Terms and definitions...5
  • 4 Method principle and measuring range...6
  • 5 Performance index and test method...7
  • 6 Technical requirements...10
  • 7 Operating instructions...12

Foreword

To implement "Environmental Protection Law of the People's Republic of China" and

"Water Pollution Prevention Law of the People's Republic of China", normalize the

technical performance for water quality automatic on-line monitor of chromium (VI),

improve the ability of water environment monitoring, this Standard is formulated.

This Standard specifies the performance, test method and technical requirement for

water quality automatic on-line monitor of chromium (VI).

This Standard was first-time released.

This Standard was organized and formulated by Ministry of Environmental Protection -

Department of Science, Technology and Standard.

Drafting organizations of this Standard. China Leather and Footwear Industry

Research Institute, Beijing Technology and Business University, Universtar Science

and Technology (Shenzhen) Co., Ltd., Hangzhou Focused Photonics Environmental

Science and Technology Co., Ltd., Hunan Lihe Science and Technology Development

Co., Ltd., Yiwen Environmental Science Technology Co., Ltd., and American Hach

Company.

This Standard was approved by Ministry of Environmental Protection on February 11,

2011.

This Standard shall be implemented on June 1, 2011.

This Standard shall be interpreted by Ministry of Environmental Protection.

The technical requirement for water quality

automatic on-line monitor of chromium (VI)

1 Scope

This Standard specifies the performance, test method and technical requirement for

water quality automatic on-line monitor of chromium (VI).

This Standard applies to the production, application selection, and performance test of

automatic on-line monitor of chromium compound ion (VI) in surface water, sanitary

sewage and industrial waste water.

2 Normative references

The following documents or provisions are essential to the application of this document.

For the undated documents, the effective versions are applicable to this document.

GB 7467 Water quality - Determination of chromium (VI) - Diphenylcarbazide

spectrophotometric method

GB/T 13306 Plates

HJ 168 Environmental monitoring - Technical guideline on drawing and revising

analytical method standards

HJ/T 212 Standard for data communication of pollution emission auto monitoring

system

HJ 477 The technical requirement for data acquisition and transmission

equipment of pollution emission auto monitoring system

3 Terms and definitions

The following terms and definitions are applicable to this Standard.

3.1

Zero drift

It refers to, adopting the zero calibration solution specified in this Standard as the

sample to test continuously, in a certain period of time, the percentage OF changes of

indicated value of water quality automatic on-line monitor of chromium (VI) RELATIVE

to the measuring range.

3.2

Measuring range drift

It refers to, adopting the measuring-range calibration solution specified in this

Standard as the sample to test continuously, in a certain period of time, the

percentage OF changes of indicated value of water quality automatic on-line monitor

of chromium (VI) RELATIVE to the measuring range.

3.3

Mean time between failures

It refers to the ratio OF the total running time (hour) of water quality automatic on-line

monitor of chromium (VI) during the period of test TO the failure frequency (times),

expressed by "MTBF", the unit is h/time.

4 Method principle and measuring range

4.1 Method principle

Water quality automatic on-line monitor of chromium (VI) can adopt

spectrophotometric method or other analytical method.

In which, the principle of spectrophotometric method. in the acid solution, chromium

compound ion (VI) and diphenylcarbazide (DPC) react and generate the purple

compound; determine the spectrophotometer at 540mm wavelength. Above steps are

automatically controlled and completed by the on-line monitor, from water-sample

importing to concentration calculation, so as to realize the automation of chromium (VI)

monitoring.

4.2 Structure of water quality automatic on-line monitor of chromium (VI)

Sampling/metering unit. includes sample, reagent importing part, and sample and

reagent metering part.

Analytical unit. has the function of changing the measured value into electric signal

output; through controlling the unit, complete the automatically on-line analysis of

samples. At the same time, it shall also include the function aimed at zero and

measuring-range calibration.

Controlling unit. includes system controlling hardware and software, with the functions

such as data collecting, processing, display storage and data output.

4.3 Measuring range

displaying part shall be uniform and clear; there shall be no vignette, black spots,

rainbow, bubble and flicker etc. It can use the displaying tips to do the comprehensive

program operation; the character, symbol and mark of description function are neat.

6.1.3 There shall be no cracks, deformation, muddiness and glitch etc.; the surface

coating shall be uniform, without corrosion, rust, detachment and abrasion. Product

assembly shall be firm; and the components shall not be loose. The control of button,

switch and lock etc. shall be flexible and reliable.

6.2 Performance requirements

6.2.1 Sampling/metering unit
6.2.1.1 It shall be made of anti-corrosive material so that the determination result will

not be impacted because of the corrosion of reagents or actual waste water.

6.2.1.2 The measuring parts shall guarantee the accuracy of reagents and actual

waste water sampling; the operating instructions shall clarify the maximum particle

size of suspension that can go through the instrument internal pipeline.

6.2.1.3 It shall have internal pipeline self-cleaning function which can prevent from

cross contamination between different samples.

6.2.2 Analytical unit
6.2.2.1 It shall be made of anti-corrosive material of which the structure shall be easy

to be cleaned.

6.2.2.2 The output signal of determination value shall be stable. Within the

determination measuring-range specified in this Standard, performance index shall

comply with the requirements of Table 1.

6.2.2.3 It shall have the automatic zero calibration and measuring-range calibration

function that can set up automatic calibration cycle to guarantee the accuracy of

measured values.

6.2.3 Controlling unit
6.2.3.1 It shall have thee feedback function of failure information (over-range alarm,

reagent absent alarm, metering component failure alarm).

6.2.3.2 It shall have analog and digital output interfaces. Through digital interface,

remote control instructions can be received.

6.2.3.3 Data processing system shall store at least 12 months' raw data. It can set up

condition inquiry and display historical data.

6.3 Safety requirements

6.3.1 Insulation resistance between power lead-wire and enclosure shall not be less

than 20 Mohm.

6.3.2 It shall set up leakage protection device to avoid personal electric shock; It shall

also set up overload protection device to prevent the instrument from accidental

burning.

7 Operating instructions

Operating instructions of water quality automatic on-line monitor of chromium (VI)

shall at least include the following contents. on-site installation conditions and

methods, operating methods of automatic on-line monitor, usage of reagents,

common failures handling, and waste-liquid handling.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

Referenced standards

Normative references

GB 7467

How to Download HJ 609-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

HJ 609-2011

$95.00