HJ 598-2011Water quality. Determination of TNT. Sodium sulfite spectrophotometric method (English PDF)
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for HJ 598-2011 in 30 minutes.
Issued by
Ministry of Ecology and Environment
Level / Type
National · Mandatory
Issue date
February 10, 2011
Implementation date
June 1, 2011
Scope
HJ 598-2011 (Water quality. Determination of TNT. Sodium sulfite spectrophotometric method) is available as an English-translated PDF.
HJ 598-2011 — This standard specifies the sodium sulfite spectrophotometric method for the determination of TNT in water. This standard is applicable to the determination of TNT in industrial wastewater discharged during the production and use of powdered ammonium ladder explosives.
When the sample volume is 10.0 ml and the 30 mm cuvette is used, the detection limit is 0.1 mg/L and the measurement range is 0.4-10 mg/L. For samples with a TNT concentration higher than the upper limit of the method, the sample can be appropriately diluted and measured.
Found what you need?
Document preview — HJ 598-2011
National Standard of the People's Republic of China
- ICS
- 13.060
- Classification
- Z 16
- Replacing
- GB/T 13905-1992
Issued by: Ministry of Ecology and Environment
Contents
- Foreword
- 1 Scope of application
- 2 Principle of the method
- 3 Interference and elimination
- 4 Reagents and materials
- 5 Instruments and equipment
- 6 Samples
- 6.1 Sample collection and preservation
- 6.2 Preparation of samples
- 6.3 Preparation of blank samples
- 7 Analysis steps
- 7.1 Calibration
- 7.2 Determination
- 7.3 Blank test
- 8 Calculation and representation of results
- 8.1 Calculation of results
- 8.2 Results representation
- 9 Precision and accuracy
- 10 Quality Assurance and Quality Control
- 11 Waste treatment
Foreword
To protect the environment and protect the human body in order to implement the Environmental Protection Law of the People's Republic of China and the Law of the People's Republic of China on Water Pollution Prevention and Control this standard is formulated for the determination of health and standardization of TNT in water.
This standard specifies the sodium sulfite spectrophotometric method for the determination of TNT in water.
This standard is a revision of the "Sodium Sulfite Spectrophotometric Method for the Determination of Water Quality TNT" (GB/T 13905-92).
This standard was first published in 1992. The original standard drafting unit was the Fifth Design and Research Institute of China Ordnance Industry. This is the first revision.
The main revisions are as follows.
- increased interference and elimination clauses;
-- Increased preparation of the sample;
-- Added quality assurance and quality control regulations;
-- Added waste disposal provisions.
The national environmental protection standard "Water quality approved and issued by the former National Environmental Protection Agency on December 2, 1992 since the implementation of this standard.
Determination of TNT's Sodium Sulfite Spectrophotometry (GB/T 13905-92) was abolished.
This standard was formulated by the Science and Technology Standards Department of the Ministry of Environmental Protection.
This standard is mainly drafted by. Beijing Zhongbing North Environmental Technology Development Co., Ltd., China Ordnance Industry Group Corporation and Liaoyang Qing Yang Special Chemical Co., Ltd.
This standard was approved by the Ministry of Environmental Protection on February 10, 2011.
This standard has been implemented since June 1, 2011.
This standard is explained by the Ministry of Environmental Protection.
Water quality - Determination of TNT - Sodium sulfite spectrophotometric method
1 Scope of application
This standard specifies the sodium sulfite spectrophotometric method for the determination of TNT in water.
This standard is applicable to the determination of TNT in industrial wastewater discharged during the production and use of powdered ammonium ladder explosives.
When the sample volume is 10.0 ml and the 30 mm cuvette is used, the detection limit is 0.1 mg/L and the measurement range is 0.4-10 mg/L.
For samples with a TNT concentration higher than the upper limit of the method, the sample can be appropriately diluted and measured.
2 Principle of the method
At room temperature, the TNT in the sample reacts with anhydrous sodium sulfite to form yellow trinitrotoluenesulfonate, which is measured at a wavelength of 420 nm.
The amount of absorbance. Within a certain concentration range, the TNT concentration and absorbance values are in accordance with Lambert-Beer law.
3 Interference and elimination
3.1 When the wastewater has a certain color, it will interfere with the measurement. It is advisable to dilute the water sample of the same volume as the sample to 25 ml as a sample blank.
The absorbance was measured directly without the addition of sodium sulfite solution. The absorbance of the sample blank is subtracted from the absorbance of the sample, and then calculated to eliminate the color the effect of degree on the determination.
3.2 When the hardness of the sample is greater than 600 mg/L, it will interfere with the measurement results. Add 1.0 ml of ethylenediamine tetraacetate to 10.0 ml of sample the acid disodium salt solution (4.3) and 1-3 drops of sodium hydroxide solution (4.4) are used to make the pH of the water sample in the range of 10-11. Amount of reagent added should be included in the calculation of the results.
4 Reagents and materials
Analytical purification reagents that meet national standards are used for analysis, unless otherwise stated. The experimental water is freshly prepared deionized water or steamed.
Distilled water.
4.1 Concentrated sulfuric acid. rho(H2SO4) = 1.84 g/ml.
4.2 Anhydrous ethanol (C2H5OH).
4.3 EDTA-2Na solution. rho(C10H14N2Na2O8·2H2O)=0.1 g/ml.
Weigh 10 g of disodium edetate dissolved in 100 ml of water and shake well.
4.4 Sodium hydroxide solution. rho (NaOH) = 0.2 g/ml.
Weigh 20 g of sodium hydroxide in 100 ml of water and shake well.
4.5 Aluminum sulfate solution. rho[Al2(SO4)3] = 0.18 g/ml.
Weigh 18 g of aluminum sulfate dissolved in 100 ml of water and mix.
4.6 Sodium carbonate solution. rho(Na2CO3) = 0.16 g/ml.
Weigh 16 g of sodium carbonate dissolved in 100 ml of water and mix.
4.7 TNT. 2,4,6-trinitrotoluene [CH3C6H2(NO2)3].
Weigh 1.0 g of TNT (industrial product) in a small beaker, dissolve it with 10 ml of absolute ethanol (4.2), and filter with medium-speed quantitative filter paper.
Place the filtrate in a fume hood and allow it to dry naturally. Recrystallization twice, spare.
4.8 TNT standard solution. rho (TNT) = 50.0 mg/L.
Accurately weigh 0.050 g of TNT (4.7) dissolved in 3 ml of concentrated sulfuric acid (4.1), slowly add water to dissolve, and then transfer to a 1 000 ml volumetric flask.
In the middle, add water to the marking line and mix.
4.9 Anhydrous sodium sulfite solution. rho(Na2SO3) = 0.2 g/ml.
Weigh 20.0 g of anhydrous sodium sulfite dissolved in an appropriate amount of water, dissolve and transfer to a 100 ml volumetric flask, add water to the mark, and mix. this the solution is valid for 3 days.
5 Instruments and equipment
5.1 Visible spectrophotometer. with 30 mm cuvette.
5.2 Plug scale colorimetric tube. 25 ml.
5.3 Common instruments and equipment used in general laboratories.
6 Samples
6.1 Sample collection and preservation
Samples should be collected in brown glass bottles, stored at 0 to 4 ° C in the dark, and measured within 5 days.
6.2 Preparation of samples
Measure 100 ml of water in an Erlenmeyer flask, add 0.5 ml of aluminum sulfate solution (4.5), and add 0.5 ml of sodium carbonate solution (4.6).
After taking the supernatant, take the supernatant and test it.
6.3 Preparation of blank samples
The sample was replaced with experimental water, and a blank sample was prepared in the same manner as in the preparation of the sample (6.2).
7 Analysis steps
7.1 Calibration
7.1.1 Measure 0.00, 0.50, 1.00, 1.50, 2.00, 2.50, 3.00 ml TNT standard solution (4.8) placed in 7 pieces respectively in the colorimetric tube, water was added to a 10 ml engraved line, and the TNT contents were 0.00, 25.0, 50.0, 75.0, 100, 125, and 150 µg, respectively.
7.1.2 Add 5 ml of anhydrous sodium sulfite solution (4.9) to the above-mentioned stoppered colorimetric tube, dilute to 25 ml with water, and shake.
Evenly, color development for 5 min. The absorbance was measured with a 30 mm cuvette at a wavelength of 420 nm using water as a reference. Taking the absorbance as the ordinate, A calibration curve is drawn with the corresponding TNT content (µg) as the abscissa.
7.2 Determination
Take 10.0 ml of the sample (6.2) in a stoppered colorimetric tube and measure the absorbance according to the same procedure as in 7.1.2.
7.3 Blank test
Measure 10.0 ml blank sample (6.3) in a stoppered colorimetric tube and analyze according to the same procedure as in measurement (7.2).
Absorbance.
8 Calculation and representation of results
8.1 Calculation of results
The mass concentration rho (mg/L) of the TNT in the sample is calculated according to formula (1).
0m mf
rho -= × (1)
Where. rho--the mass concentration of TNT in the sample, mg/L;
M--the TNT content of the sample obtained on the calibration curve, µg;
M0--the TNT content of the blank sample found on the calibration curve, µg;
V--10 ml, sample volume;
F--dilution ratio.
8.2 Results representation
When the measurement result is less than 1 mg/L, the two decimal places are retained, and when the measurement result is greater than or equal to 1 mg/L, the three significant numbers are retained.
word.
9 Precision and accuracy
Six times of the actual samples with TNT mass concentrations of 2.46 mg/L, 4.65 mg/L, 6.18 mg/L and 9.99 mg/L were applied.
The relative standard deviations were 1.83%, 1.70%, 1.15%, and 0.64%, respectively. When the spiked amount was 20 µg, the spiked recovery was 94.4% to 102.4%.
10 Quality Assurance and Quality Control
10.1 At least one full program blank test shall be performed for each batch of samples, and the measured value shall not exceed the method detection limit.
10.2 The correlation coefficient of the calibration curve should be greater than or equal to 0.999.
10.3 Each batch of sample analysis shall have an intermediate checkpoint, and the relative deviation of the measured value from the corresponding point of the calibration curve shall not exceed 10%.
10.4 At least 10% of parallel samples should be determined for each batch of samples, and at least one parallel sample should be determined for less than 10 samples.
The deviation should be less than 20%.
10.5 Each batch of samples should be tested by at least one spiked recovery analysis, and the actual sample spike recovery should be controlled at 90% to 110%.
11 Waste treatment
The waste liquid and waste water generated during the test should be collected and disposed of properly.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
How to Download HJ 598-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
HJ 212-2025 — Technical requirements for data transmission of pollutant automatic monitoring and surveillance systems
HJ 1322-2023 — Technical specification for emission remote supervision system of non-road mobile machinery
HJ 1231-2022 — Soil environment - Vocabulary
Secure payment via Stripe
Payments accepted
HJ 598-2011
$184.00