HG/T 2876-2009Cellular material fo rubber-plastics shoes. Determination of compression set (English PDF)
Also coversHGT2876-2009
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for HG/T 2876-2009 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of PRC
Level / Type
National · Recommended
Issue date
December 4, 2009
Implementation date
June 1, 2010
Scope
HG/T 2876-2009 (Cellular material fo rubber-plastics shoes. Determination of compression set) is available as an English-translated PDF.
HG/T 2876-2009 is the Chinese standard "Cellular material fo rubber-plastics shoes. Determination of compression set". Its scope clause reads: This standard specifies the test method for the compressive set of cellular material for rubber-plastics shoes.
This standard applies to the determination of compression set of cellular material for rubber-plastics shoes. Its clauses include terms and definitions; principle; conditioning of specimen and test environment; test steps; test results.
It was issued by the Ministry of Industry and Information Technology of PRC on 2009-12-04 and took effect on 2010-06-01.
Found what you need?
Document preview — HG/T 2876-2009
National Standard of the People's Republic of China
- ICS
- 61.060
- Classification
- Y 78
Issued by: Ministry of Industry and Information Technology of PRC
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Terms and definitions...4
- 4 Principle...4
- 5 Test devices and instruments...5
- 6 Specimen...5
- 7 Conditioning of specimen and test environment...6
- 8 Test steps...6
- 9 Test results...6
- 10 Test report...7
1 Scope
This standard specifies the test method for the compressive set of cellular material for rubber-plastics shoes.
This standard applies to the determination of compression set of cellular material for rubber-plastics shoes.
2 Normative references
The provisions in following documents become the provisions of this standard through reference in this standard. For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this standard;
however, parties who reach an agreement based on this standard are encouraged to study if the latest versions of these documents are applicable.
For undated references, the latest edition of the referenced document applies.
GB/T 2941 Rubber - General procedures for preparing and conditioning test pieces for physical test methods (GB/T 2941-2006, idt ISO 23529.2004)
3 Terms and definitions
The following terms and definitions apply to this standard.
3.1
Compression set
The rate of change of the geometrical dimension produced in the direction of the force of the specimen after the external force which causes the compressive deformation is completely removed.
4 Principle
The cellular material of rubber-plastics shoes is compressed by external force, the material will deform along the direction of the force. When the external force is removed, the material still cannot be restored to its original geometry. In the
The thickness is 10.0 mm ± 0.2 mm. Grind it according to the provisions of GB/T
2941. For the finished shoes, it may take sample from the cellular heel bottom.
6.2 If the thickness of the specimen is less than 10 mm, it may bond two layers.
After letting it be standing for 2 h, prepare it into a specimen. However, the test results cannot be compared with the test results of the standard specimen.
6.3 The surface of the specimen shall be flat and shall not be left with a patterned or dense skin. The compressed surface is consistent with the compression surface of the finished shoe when it is in use.
7 Conditioning of specimen and test environment
7.1 The storage of samples and specimens shall be carried out in accordance with the provisions of GB/T 2941.
7.2 The test shall be carried out under the standard temperature and humidity of the laboratory in accordance with the provisions of GB/T 2941.
8 Test steps
8.1 Number the specimen. Measure the geometry of the specimen.
8.2 Use a vernier caliper to measure the length and width of the specimen, accurate to 0.02 mm.
8.3 Use a thickness gauge to measure the height before and after compression
of the specimen, accurate to 0.01 m.
8.4 The number of specimens for each sample shall be not less than three. The height of the same set of specimens shall not differ by more than 0.1 mm.
8.5 Place the specimen in the fixture. Tighten the nut to the ring stopper. The specimens shall have sufficient spacing in the fixture, so that the specimens do not come into contact with one another when compressed.
8.6 The compression time is 72 h ± 2 h. Take out the specimen after reaching the time. Let it be standing for 2 h. Then measure the height of specimen after restoration.
9 Test results
The compression set of the specimen is calculated by the following formula.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
How to Download HG/T 2876-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2941-2025 — Rubber - General procedures for preparing and conditioning test pieces for physical test methods
GB/T 29411-2012 — Technical specification of hydrogen-oxygen generator with water electrolyte
GB/T 29412-2012 — Adsorber of pressure swing adsorption for hydrogen purification