GB/Z 45378-2025Non-destructive testing - Methods for absolute calibration of acoustic emission transducers by the reciprocity technique (English PDF)
无损检测 基于互易性技术的声发射传感器绝对校准方法
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for GB/Z 45378-2025 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 28, 2025
Implementation date
March 28, 2025
Scope
GB/Z 45378-2025 is the English-translated version of 无损检测 基于互易性技术的声发射传感器绝对校准方法.
GB/Z 45378-2025 is a Chinese non-destructive testing guidance document, modified from ISO/TR 13115:2011, on calibrating acoustic emission transducers absolutely by the reciprocity technique.
Three reversible transducers of the same type are paired on a solid transmission medium, and absolute sensitivity is derived from purely electrical measurements of transmitting current and receiving voltage, with no mechanical sound source or reference sensor.
The document covers calibration preparation, the three-transducer method, a two-transducer method using a sensor already calibrated for its transmitting response, and pulse response calibration through an inverse Fourier transform.
Rayleigh surface waves and longitudinal waves are both treated, and a clause explains how calibration results are presented. It was issued on 28 March 2025.
Found what you need?
Document preview — GB/Z 45378-2025
National Standard of the People's Republic of China
- ICS
- 19.100
- Classification
- J 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Calibration Preparation
- 5 Three-sensor calibration method
- 6 Dual Sensor Calibration Method
- 7 Pulse Response Calibration Method
- 8 Presentation of calibration results
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.
This document is modified to adopt ISO /T R13115.2011 "Absolute calibration method for acoustic emission sensors based on reciprocity technology for non-destructive testing" The document type was adjusted from ISO 's technical report to my country's national standardization guidance technical document.
Compared with ISO /T R13115.2011, this document has made the following structural adjustments.
--- 5.2~5.4 in Chapter 5 correspond to 5.1~5.3 in Chapter 5 of ISO /T R13115.2011, with 5.1 added;
--- 6.2~6.4 in Chapter 6 correspond to 6.1~6.3 in Chapter 6 of ISO /T R13115.2011, with 6.1 added;
--- 7.2~7.5 in Chapter 7 correspond to 7.1~7.4 in Chapter 7 of ISO /T R13115.2011, with 7.1 added. The following editorial changes were made to this document.
---Change the unit of burst signal period T from "s" to "ms" (see the unit in Figure 1);
---Change "|I'R(f)|" in 6.3.2 to "|I'L(f)|", and change "|U'R(f)|" to "|U'L(f)|".
Introduction
The first-level calibration method for acoustic emission sensors is ISO 12713:1998[1], which introduces the vibration surface pulse method using Rayleigh surface waves for calibration.
The glass capillary fracture is used as the sound source, and the dynamic displacement of the surface is measured using a standard capacitive sensor.
According to ISO 12714:1999[2], the receiving sensitivity of the calibrated sensor is measured comparatively using the vibrating surface pulse method.
This document describes a method for calibrating the absolute sensitivity of acoustic emission sensors using Rayleigh surface waves and longitudinal waves by means of the reciprocity technique.
Since the reciprocity parameters have been derived, the absolute sensitivity can be determined by purely electrical measurements without the use of a mechanical sound source or a reference sensor.
The operating procedures of the vibrating surface pulse method and the reciprocity technique are different, but the two calibration methods have a common theoretical basis.
The vibration surface pulse method, in theory, calculates the surface displacement based on the Lamb wave theory (reference [7]), while for the reciprocity calibration method, the Rayleigh The reciprocity parameters of the wave calibration also come from the Lamb wave theory. For Rayleigh surface wave calibration, the cyclic test has been carried out and it has been determined that the The absolute sensitivities obtained by the two methods are in good agreement.
The purpose of both methods is the same, which is to establish the consistency of acoustic emission testing to form a basis for data correlation and to provide a basis for different laboratories to compare different Provide interpretation of acoustic emission test results obtained over time.
This document introduces the methods of three-sensor calibration, two-sensor calibration and pulse response calibration.
The three acoustic emission sensors prepared are all reversible sensors of the same type, configured as three pairs of independent emission sensors on the solid transmission medium.
Each pair of sensors measures the transmitted signal current and received signal voltage as a function of frequency and determines the The absolute sensitivity amplitude of Rayleigh surface waves and longitudinal waves is the frequency response. The acoustic emission sensor calibrated by three sensors can be used as an acoustic emission sensor.
The radiating or receiving sensor can be used to calibrate any one of the sensors to be calibrated by a relatively simple procedure.
The absolute receiving sensitivity of the acoustic emission sensor to be calibrated is determined by using a sensor whose emission current response has been calibrated by the three-sensor calibration method.
In addition, the impulse response of each acoustic emission sensor can be determined by three-sensor calibration.
In the calibration, the absolute sensitivity amplitude and phase frequency are obtained by three-sensor calibration based on the reciprocity parameter in complex form.
The impulse response is determined by performing an inverse Fourier transform on the frequency response.
1 Scope
This paper describes the calibration of the absolute sensitivity frequency of three reversible acoustic emission sensors of the same type using the reciprocity technique. Three-sensor calibration method for rate response.
This document describes the use of sensors whose emission current responses have been obtained using a three-sensor calibration method to determine the acoustic emission sensor to be calibrated.
Dual sensor calibration method based on absolute sensitivity amplitude-frequency response of sensors.
This document describes how to calibrate the sensors by measuring the frequency response using a three-sensor calibration method and then performing an inverse Fourier transform.
The absolute sensitivity pulse response of the sensor is used to express the calibration result.
2 Normative references
The contents of the following documents constitute essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.
GB/T 12604.4-2005 Non-destructive testing terminology Acoustic emission testing (ISO 12716:2001, IDT)
3 Terms and definitions
The terms and definitions defined in GB/T 12604.4-2005 and the following apply to this document.
3.1 Reciprocity technique
Three reversible acoustic emission sensors of the same type are arranged on a solid transmission medium (3.8) to form three pairs of independent emission sensors and Receiving sensors, absolute sensitivity (3.3) is determined by the calibration method of the electrical measurements of the transmitting current and receiving voltage of each sensor pair.
3.2 Reversible transducer
A sensor that can be used for both transmitting and receiving.
3.3 Absolute sensitivity
The emission current response or receiving voltage sensitivity of the acoustic emission sensor (3.4).
3.4 Receiving voltage sensitivity
The ratio of the open-circuit output voltage of the receiving acoustic emission sensor to the vertical component of the vibration velocity at the location where the sensor is placed.
3.5 Transmitting current response
The ratio of the vertical component of the vibration velocity at the index point (3.6) to the input current of the acoustic emission sensor used for transmission.
3.6 Index point
A point located on the surface of the transmission medium (3.8) at a specified distance and direction from the transmitting acoustic emission sensor.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/Z 45378-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12604.4-2005 — Non-destructive testing -- Terminology -- Terms used in acoustic emission testing