GB/Z 43963-2024Guidance for determination of clearances, creepage distances and requirements for solid insulation for equipment with a rated voltage above 1 000 V AC and 1 500 V DC, and up to 2 000 V AC and 3 000 V DC. (English PDF)

Also coversGBZ43963-2024

Open the GB/Z 43963-2024 preview as PDF

Preview — first pages of GB/Z 43963-2024

This is a limited preview

Buy now to download the full PDF

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

April 25, 2024

Implementation date

November 1, 2024

Scope

GB/Z 43963-2024 (Guidance for determination of clearances, creepage distances and requirements for solid insulation for equipment with a rated voltage above 1 000 V AC and 1 500 V DC, and up to 2 000 V AC and 3 000 V DC.) is available as an English-translated PDF.

GB/Z 43963-2024 — This document is a technical specification that provides technical committees with the criteria for determining rated voltages from 1000V to:2000V AC and 1500V DC: Insulation coordination guide for equipment with rated voltage not exceeding 1000 V AC and 1500 V DC, and with higher For insulation coordination equipment with a voltage of 100 V or lower internal voltage, see IEC 60664-1 for relevant requirements: This document applies to equipment at altitudes up to:2000m and provides guidance for use at higher altitudes: This document specifies the electrical clearances, creepage distances and solid insulation guidelines for equipment to meet safety requirements, including relevant electrical tests method: NOTE: Since functional insulation requirements are not safety requirements, no corresponding provisions are made: This document does not deal with the determination of the following distances: ---Insulation by liquid; --- Passing gases other than air; ---By compressed air:

Document preview — GB/Z 43963-2024

National Standard of the People's Republic of China

ICS
29.080.30
Classification
K 30

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope1
  • 2 Normative references1
  • 3 Terms and Definitions2
  • 4 Basic information for determining insulation requirements5
  • 5 Rules for determining size8
  • 6 Tests and measurements13
  • References19

Foreword

This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents"

Drafting:

This document is equivalent to IEC TS62993:2017 "Determination of rated voltage above 1000V AC to:2000V, DC 1500V

Guide to the values of electrical clearances and creepage distances for equipment between 3000V and above and to the requirements for solid insulation:

The technical specifications are adjusted to become guiding technical documents for national standardization in my country:

Introduction

This document provides a smooth transition from low voltage (not exceeding 1000 V ac and 1500 V dc) as specified in IEC 60664 (all parts):

The additional insulation coordination for the transition to high voltage (IEC 60071-1 gives a range greater than 1000V, but the regulations given all start from 3600V)

The IEC 60071-1 standard does not contain provisions for personal safety requirements, and IEC 60071-1 does not provide creepage distance values:

Because many standard committees require the voltage range of AC 1000V to:2000V and DC 1500V to 3000V to be given:

This document is specially formulated to determine the electrical clearances, creepage distances and solid insulation methods for equipment within the enclosure:

This document does not intend to extend the upper limit of the low voltage range, which remains not more than 1000 V AC and 1500 V DC:

Make sure the rated voltage is above AC 1000V:

2000V, DC 1500V and above to 3000V

The values of electrical clearance and creepage distance between devices

and guidance on solid insulation requirements

1 Scope

This document is a technical specification that provides technical committees with the criteria for determining rated voltages from 1000V to:2000V AC and 1500V DC:

Insulation coordination guide for equipment with rated voltage not exceeding 1000 V AC and 1500 V DC, and with higher

For insulation coordination equipment with a voltage of 100 V or lower internal voltage, see IEC 60664-1 for relevant requirements:

This document applies to equipment at altitudes up to:2000m and provides guidance for use at higher altitudes:

This document specifies the electrical clearances, creepage distances and solid insulation guidelines for equipment to meet safety requirements, including relevant electrical tests

method:

NOTE: Since functional insulation requirements are not safety requirements, no corresponding provisions are made:

This document does not deal with the determination of the following distances:

---Insulation by liquid;

--- Passing gases other than air;

---By compressed air:

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document:

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to

This document:

GB/T 2423:2-2008 Environmental testing for electric and electronic products Part 2: Test methods Test B: High temperature (IEC 60068-2-2:

2007, IDT)

GB/T 2423:3-2016 Environmental testing Part 2: Test method Test Cab: Steady state damp heat test (IEC 60068-2-78:

2012, IDT)

GB/T 2423:22-2012 Environmental testing Part 2: Test method Test N: Temperature change (IEC 60068-2-14:

2009, IDT)

GB/T 16935:1-2023 Insulation coordination for equipment in low voltage power supply systems Part 1: Principles, requirements and tests

(IEC 60664-1:2020,IDT)

IEC 60068-2-78 Environmental testing Part 2-78: Test Cab: Steady state damp heat test (Environmenttesting-

Note: GB/T 2423:3-2016 Environmental testing Part 2: Test method Test Cab: Steady state damp heat test (IEC 60068-2-78:2012, IDT)

Note: GB/T 4207-2012 Determination of tracking resistance index and comparative tracking index of solid insulating materials (IEC 60112:2009, IDT)

IEC 61180:2016 High-voltage test technical definitions, test and procedure requirements, test equipment for low-voltage electrical equipment (High-

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 2423 · IEC 60068 · GB/T 16935 · IEC 60664 · GB/T 4207-2012 · IEC 60112 · IEC 61180

How to Buy GB/Z 43963-2024

  1. 1Add to cart. Click the "Buy GB/Z 43963-2024" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 43963-2024

$455.00

$385.00for partners