GB/Z 35588-2017Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits (English PDF)

Also coversGBZ35588-2017

Open the GB/Z 35588-2017 preview as PDF

Preview — first pages of GB/Z 35588-2017

This is a limited preview

Buy now to download the full PDF

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

December 29, 2017

Implementation date

July 1, 2018

Scope

GB/Z 35588-2017 (Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits) is available as an English-translated PDF.

GB/Z 35588-2017 — This guidance document provides a method for measuring the flow of wet gas using a differential pressure device installed in a circular sectioned pipe. This guidance is applicable to gas-liquid two-phase mixed fluids (6.4.3, 6.4.5, 7.5.3) with a gas volume percentage of 95% or more And 7.5.5 gives a clear limitation of the mixed fluid). This Guidance Document is a supplement to GB/T 2624. 6.4.1 and 7.5.1 to The range of gases and liquids used for the derivation of the formulas in this guidance is presented. These formulas may not be suitable for use with test liquids Different liquids, especially high viscosity liquids. Although the correction formulas given in this guidance document are applicable to most gases and liquids with comparable gas-liquid density ratios, For gas flow, not only is it necessary to evaluate the information required for a single-phase fluid, but also other information is needed. Under some conditions it is only necessary to measure the pressure loss The tracer can be used to measure the flow of liquid; the total mass flow of the fluid is known (as compared to natural gas/liquid fluids, wet steam fluids are more likely to have This requirement); dampening calorimeters can be used in wet steam fluids. This guidance document includes the measurement of wet gas using a venturi or orifice plate. This guidance document is applicable only to wet gas containing one liquid and is not suitable for use in the oil and gas industry.

Document preview — GB/Z 35588-2017

National Standard of the People's Republic of China

ICS
17.120.10
Classification
N 12

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions

Foreword

This instructional document has been drafted in accordance with the rules given in GB/T 1.1-2009.

This guideline uses the translation method identical with ISO /T R11583.2012 "with a differential pressure mounted in a circular sectioned pipe

Set the measurement of wet gas flow. "

Our document, which corresponds in a consistent manner to the international documents that are normative references in this Guidance Document, is as follows.

--- GB /Z 35140-2017 fluid flow measurement using differential pressure device GB/T 2624 outside the area of the orifice, nozzle and venturi

Guidelines for using tubes (ISO /T R15377.2007, IDT)

--- GB/T 17611-1998 Measurement of fluid flow in closed conduits Terms and symbols (idtISO 4006.1991)

--- GB/T 26801-2011 closed pipe fluid flow measurement between the primary device and secondary device pressure signal transmission

Connection Method (ISO 2186.2007, IDT)

This guidance document is proposed by China Machinery Industry Federation.

This Guidance Document is governed by the National Technical Committee for Measurement, Control and Automation of Industrial Processes (SAC/TC124).

The guiding technical document is drafted by Shanghai Institute of Industrial Automation Instrumentation.

The guidance of technical documents to participate in the drafting unit. Beijing Ruipu ternary Instrument Co., Ltd., Jiangyin City, throttling Plant Co., Ltd., Zhejiang

Cangnan Instrument Group East Star Energy Technology Co., Ltd., Zhejiang Tianxin Instrument Technology Co., Ltd., Shanghai Instrumentation Automatic Control System Test

By, Dandong Tongbo Electric Group, Zhejiang Jinlong Control Equipment Co., Ltd.

Introduction

Part 1 of GB/T 2624-2006 "Measurement of Manifold Fluid Flow with Differential Pressure Devices Installed in Circular Cross-Sectional Ducts", Part 2

Section 4 and Section 4 contain provisions for venturi and orifice plates, but only for the measurement of full pipe single phase fluids.

If the measured fluid is a wet gas, it will produce "virtual high", which can be corrected by the corresponding wet gas correction equation.

With the installation of circular cross-section of the pipe in the differential pressure device

Measure wet gas flow

1 Scope

This guidance document provides a method for measuring the flow of wet gas using a differential pressure device installed in a circular sectioned pipe.

This guidance is applicable to gas-liquid two-phase mixed fluids (6.4.3, 6.4.5, 7.5.3) with a gas volume percentage of 95% or more

And 7.5.5 gives a clear limitation of the mixed fluid). This Guidance Document is a supplement to GB/T 2624. 6.4.1 and 7.5.1 to

The range of gases and liquids used for the derivation of the formulas in this guidance is presented. These formulas may not be suitable for use with test liquids

Different liquids, especially high viscosity liquids.

Although the correction formulas given in this guidance document are applicable to most gases and liquids with comparable gas-liquid density ratios,

For gas flow, not only is it necessary to evaluate the information required for a single-phase fluid, but also other information is needed. Under some conditions it is only necessary to measure the pressure loss

The tracer can be used to measure the flow of liquid; the total mass flow of the fluid is known (as compared to natural gas/liquid fluids, wet steam fluids are more likely to have

This requirement); dampening calorimeters can be used in wet steam fluids.

This guidance document includes the measurement of wet gas using a venturi or orifice plate.

This guidance document is applicable only to wet gas containing one liquid and is not suitable for use in the oil and gas industry.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 2624.1-2006 Measurement of full pipe fluid flow using differential pressure devices installed in circular sectioned pipes - Part 1. General

Principles and requirements (ISO 5167-1.2003, IDT)

GB/T 2624.2-2006 Measurement of full pipe fluid flow using a differential pressure device installed in a circular sectioned pipe - Part 2 - Orifice

(ISO 5167-2.2003, IDT)

GB/T 2624.4-2006 Manifold fluid flow measurement using differential pressure devices installed in circular sectioned pipes - Part 4 Ventura

In tube (ISO 5167-4.2003, IDT)

ISO 2186 Measurement of fluid flow in closed conduits Connection of pressure signals between primary and secondary units (Fluid

flowinclosedconduits-Connectionsforpressuresignaltransmissionsbetweenprimaryandsecondary

elements

ISO 4006 closed pipe fluid flow measurement terms and symbols (Measurementoffluidflowinclosedcon-

duits-Vocabularyandsymbols)

ISO /T R15377 Fluid Flow Measurement with Differential Pressure Devices Use of Orifices, Nozzles and Venturi Beyond ISO 5167

Guideline (Measurementoffluidflowbymeansofpressure-differentialdevices-Guidelinesforthespecifi-

cationoforificeplates, nozzlesandVenturitubesbeyondthescopeofISO 5167)

3 Terms and definitions

ISO 4006 and GB/T 2624.1-2006 define the following terms and definitions apply to this document.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 2624.1-2006 · ISO 5167 · GB/T 2624.2-2006 · GB/T 2624.4-2006 · ISO 2186 · ISO 4006

How to Buy GB/Z 35588-2017

  1. 1Add to cart. Click the "Buy GB/Z 35588-2017" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 35588-2017

$300.00

$255.00for partners