GB/Z 192.1-2026Industrial process control devices - Thermographic cameras - Part 1: Metrological characterization (English PDF)

工业过程控制装置 热像仪 第1部分:计量特性

Preview PDF

This is a limited preview

Buy now to download the full PDF (35 pages)

Need quotation for your management?

Get a formal quotation for GB/Z 192.1-2026 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 2, 2026

Implementation date

July 2, 2026

Scope

GB/Z 192.1-2026 is the English-translated version of 工业过程控制装置 热像仪 第1部分:计量特性.

GB/Z 192.1-2026 is the Chinese standard "Industrial process control devices - Thermographic cameras - Part 1: Metrological characterization".

Its scope clause reads: This document applies to the declaration and testing of technical data in the parameter tables and instruction manuals of thermal imagers used for measuring surface temperature in the field of metrology.

Limitations of machine systems. This document describes the standard test methods for determining relevant metrological data for thermal imagers. Manufacturers and distributors can select the relevant data and make declarations.

These parameters conform to the requirements of this document. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/Z 192.1-2026

National Standard of the People's Republic of China

ICS
25.040.40
Classification
N 10

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Introduction IV
  • 1.Scope
  • 2 Normative References
  • 3.Terms and Definitions
  • 4 symbols
  • 5 Abbreviations
  • 6.Determination of technical data
  • 6.2 Measurement Temperature Range
  • 6.3 Noise Equivalent Temperature Difference (NETD)
  • 6.4 Measuring Distance
  • 6.5 Field of View (FOV)
  • 6.6 Number of pixels
  • 6.7 Detector Specifications Used (Number of Detector Elements Used)
  • 6.8 Instantaneous Field of View (IFOV)
  • 6.9 Slit Response Function (SRF)
  • 6.10 Minimum Field of View (MFOVT) for Temperature Measurement
  • 6.11 Spectral range
  • 6.12 Emittance setting
  • 6.13 Influence of Internal Instrument Temperature
  • 6.14 Humidity Effects
  • 6.15 Long-term stability
  • 6.16 Short-term stability
  • 6.17 Repeatability
  • 6.18 Interchangeability
  • 6.19 Response time
  • 6.22 Integral time setting range
  • 6.23 Refresh rate
  • 6.24 Non-uniformity (detector response non-uniformity)
  • 6.25 Non-uniform equivalent temperature difference (IETD)
  • 6.26 Operating temperature range and air humidity range
  • 6.27 Source Size Effect (SSE)
  • Appendix A (Informative) Change in Indicated Temperature Caused by a 1% Change in Radiative Exchange
  • References

1 Scope

This document applies to the declaration and testing of technical data in the parameter tables and instruction manuals of thermal imagers used for measuring surface temperature in the field of metrology.

Limitations of machine systems.

This document describes the standard test methods for determining relevant metrological data for thermal imagers. Manufacturers and distributors can select the relevant data and make declarations.

These parameters conform to the requirements of this document.

2 Normative references

This document has no normative references.

3 Terms and Definitions

The following terms and definitions apply to this document.

The URLs for the terminology databases maintained by ISO and IEC for standardization are as follows.

Note. The term “uncertainty” used in this document is strictly derived from the above database, and more specifically from ISO /IEC Guide 98-3.2008.

3.1 blackbody radiator

A radiation source whose radiation characteristics closely approximate Planck's radiation law.

Note. A blackbody radiation source is a thermal radiation source with an effective emissivity close to 1.

3.2 Coverage factor

A numerical factor used as a multiplier for synthesizing standard uncertainty to obtain expanded uncertainty.

Note. The inclusion factor k is a number greater than 1, usually between 2 and 3.

3.3

The actual number of detector elements (detector pixels) used to record the image.

Note. This document does not use the commonly used term "pixel" because it can refer to both detectors (detector elements) and images (pixels).

3.4 exposure time

In the event of a sudden change, to ensure that the thermal imager's output signal reaches a predetermined value, the minimum amount of input (temperature or radiation) must be applied.

Interval.

3.5

The range of target emissivity that a thermal imager can be set to.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 35 pages — is available in the English PDF.

Similar standards

How to Download GB/Z 192.1-2026

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
35 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 192.1-2026

$545.00