GB/Z 17625.13-2020Electromagnetic compatibility. Limits. Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems (English PDF)
Also coversGBZ17625.13-2020
Open the GB/Z 17625.13-2020 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
November 19, 2020
Implementation date
June 1, 2021
Scope
GB/Z 17625.13-2020 (Electromagnetic compatibility. Limits. Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems) is available as an English-translated PDF.
GB/Z 17625.13-2020 — This part of the "Electromagnetic Compatibility Limits" is for unbalanced facilities (that is, three-phase facilities that cause voltage imbalance) to connect to public medium voltage, high voltage, and ultra The basic requirements of high-voltage power systems (low-voltage facilities will be regulated in other national standard documents) provide a guiding principle. Imbalance in this section Facility refers to a three-phase facility (which can be a load or power generation equipment) that causes an unbalanced system voltage. No access specifically for single-phase facilities Explain, because the access of such facilities is controlled by the system operator or owner. But when considering the access of single-phase facilities, these general The principles can also be applied. The main goal of this part is to guide the engineering practice of system operators or owners, so as to provide all connected users with Sufficient quality of service. But when it comes to facilities, this section is not intended to replace the emission limit standards for equipment. This part focuses on the capacity allocation of the system to absorb disturbance; it does not involve how to alleviate the disturbance and how to expand the capacity of the system. Since the criteria highlighted in this section are based on certain necessary simplifications and assumptions, there is no guarantee that this method will be effective for all injustices. Balance the load to provide the best solution. In terms of engineering, it is advisable to flexibly use and evaluate the recommended recommendations in all or part of the evaluation procedures. method. When facilities are connected to the system and may cause system imbalance, the system operator or owner is responsible for putting forward regulatory requirements. Usually show Disturbance facilities are understood as the user's complete facilities (that is, including balanced and unbalanced parts). The imbalances involved are basically divided into two categories. * Unbalanced facilities that absorb negative sequence current and generate negative sequence voltage in the power supply system. Such typical facilities include electric arc furnaces, electric Locomotives (usually connected to the public high-voltage power grid), and various unbalanced three-phase facilities (usually connected to the medium-voltage or low-voltage power grid). The negative sequence voltage is superimposed on the terminal voltage of the rotating machine, which will generate additional heat loss. Negative sequence voltage will also cause the converter equipment to produce Generate non-characteristic harmonics (usually the third harmonic in the positive sequence). * Connected to unbalanced facilities with neutral line system can also absorb zero sequence current. According to the wiring type of the power transformer, zero sequence The current may or may not be transferred to the power supply system. The zero sequence current flowing in the neutral grounded system will A zero sequence unbalanced voltage is generated in the phase voltage. Usually it is not by setting the emission limit to control the zero sequence unbalanced voltage, It is controlled through system design and maintenance. The neutral point is not grounded, or the facilities connected between the phases are not affected by this The influence of similar zero sequence unbalanced voltage. This section only provides guidance on how to coordinate the negative sequence voltage between different voltage levels to meet the compatibility level of the power point. Not right The zero sequence voltage imbalance limits the compatibility level. Compared with the negative sequence voltage imbalance, it is generally considered that the zero sequence voltage imbalance is between different voltage levels. Inter-coordination is irrelevant. But for the case where the neutral point is effectively grounded via impedance (that is, the ratio of the zero sequence reactance X0 to the positive sequence reactance X1 satisfies 0< X0/X1<=3), pay attention to this kind of voltage imbalance, especially when the connection method of the transformer allows the zero sequence component to penetrate between the medium voltage and the low voltage. Transparent occasions. Note. Since different countries have different delimitations of voltage levels (see 601-01-28 in IEC 60050-601.1985), this section uses system voltage The following terms. ---Low voltage (LV), refers to Un<=1kV; ---Medium voltage (MV), refers to 1kV \u003cUn<=35kV; ---High voltage (HV), refers to 35kV \u003cUn<=230kV; --- Extra high voltage (EHV), refers to Un >230kV. In this section, the function of the system is more important than the nominal voltage. For example, it can be specified that the "planning level" of the high-voltage system used for power distribution is between medium voltage and Between the planning levels of high-pressure systems.
Document preview — GB/Z 17625.13-2020
National Standard of the People's Republic of China
- ICS
- 33.100.10
- Classification
- L 06
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- 1 Scope1
- 2 Normative references2
- 3 Terms and definitions2
- 4 Basic concepts of electromagnetic compatibility related to voltage imbalance6
- 4.1 Compatibility level6
- 4.2 Planning level6
- 4.3 Explanation of the concept of electromagnetic compatibility7
- 4.4 Emission level8
- 5 General9
- 5.1 Level 1.Simplified assessment of harassment emissions9
Foreword
The "Electromagnetic Compatibility Limits" is divided into the following parts.
---GB 17625.1-2012 electromagnetic compatibility limit harmonic current emission limit (equipment input current per phase <= 16A);
---GB/T 17625.2-2007 The electromagnetic compatibility limit is for the equipment with rated current <= 16A per phase and unconditional access in public
Restrictions on voltage changes, voltage fluctuations and flicker generated in low-voltage power supply systems;
---GB /Z 17625.3-2000 Electromagnetic compatibility limit is used for equipment with rated current greater than 16A in low-voltage power supply system
Voltage fluctuations and flicker limits;
---GB /Z 17625.4-2000 Electromagnetic Compatibility Limits Evaluation of Distortion Load Emission Limits in Medium and High Voltage Power Systems;
---GB /Z 17625.5-2000 Electromagnetic Compatibility Limits Evaluation of emission limits for fluctuating loads in medium and high voltage power systems;
---GB /Z 17625.6-2003 Electromagnetic compatibility limit for equipment with a rated current greater than 16A in the low-voltage power supply system
The limit of the generated harmonic current;
---GB/T 17625.7-2013 The electromagnetic compatibility limit is limited to equipment with a rated current <=75A and conditional access in the public low
Limitations of voltage changes, voltage fluctuations and flicker generated in the voltage power supply system;
---GB/T 17625.8-2015 Electromagnetic compatibility limit The input current per phase is greater than 16A and less than or equal to 75A.
Harmonic current limits generated by equipment in low-voltage systems;
---GB/T 17625.9-2016 Electromagnetic compatibility limit Signal transmission emission level, frequency band and electromagnetic
Harassment level;
Evaluation of the emission limit;
---GB /Z 17625.14-2017 Harmonic, interharmonic and voltage of electromagnetic compatibility limit disturbance device connected to low-voltage power system
Evaluation of fluctuating and unbalanced emission limits;
---GB /Z 17625.15-2017 Electromagnetic compatibility limit low-frequency electromagnetic immunity and power generation of distributed generation systems in low-voltage power grids
Evaluation of shooting requirements.
This part is part 13 of "Electromagnetic Compatibility Limits".
This section was drafted in accordance with the rules given in GB/T 1.1-2009.
The translation method used in this part is equivalent to the IEC /T R61000-3-13.2008 "Electromagnetic Compatibility (EMC) Part 3-13.Limits
Evaluation of Emission Limits for Unbalanced Facilities Entering Medium Voltage, High Voltage, and Extra High Voltage Power Systems.
The Chinese documents that have a consistent correspondence with the international documents cited in this section are as follows.
---GB/T 4365-2003 Electrotechnical terminology electromagnetic compatibility [IEC 60050(161).1990, IDT].
This section has made the following editorial changes.
---In order to be consistent with the existing standard series, the standard name is revised to "Electromagnetic Compatibility Limits Access to Medium Voltage, High Voltage, and Extra High Voltage Power Systems
Evaluation of emission limits for unbalanced facilities;
---Incorporate the technical errata of the international standard IEC /T R61000-3-13.2008/Cor.1.2010, and use the vertical double line (||)
Marked in the margins of the terms they refer to.
This part is proposed and managed by the National Electromagnetic Compatibility Standardization Technical Committee (SAC/TC246).
Drafting organizations of this section. China Electric Power Research Institute Co., Ltd., China Southern Power Grid Co., Ltd. EHV Transmission Company Overhaul
Test Center, State Grid Corporation of China.
1 Scope
This part of the "Electromagnetic Compatibility Limits" is for unbalanced facilities (that is, three-phase facilities that cause voltage imbalance) to connect to public medium voltage, high voltage, and ultra
The basic requirements of high-voltage power systems (low-voltage facilities will be regulated in other national standard documents) provide a guiding principle. Imbalance in this section
Facility refers to a three-phase facility (which can be a load or power generation equipment) that causes an unbalanced system voltage. No access specifically for single-phase facilities
Explain, because the access of such facilities is controlled by the system operator or owner. But when considering the access of single-phase facilities, these general
The principles can also be applied. The main goal of this part is to guide the engineering practice of system operators or owners, so as to provide all connected users with
Sufficient quality of service. But when it comes to facilities, this section is not intended to replace the emission limit standards for equipment.
This part focuses on the capacity allocation of the system to absorb disturbance; it does not involve how to alleviate the disturbance and how to expand the capacity of the system.
Since the criteria highlighted in this section are based on certain necessary simplifications and assumptions, there is no guarantee that this method will be effective for all injustices.
Balance the load to provide the best solution. In terms of engineering, it is advisable to flexibly use and evaluate the recommended recommendations in all or part of the evaluation procedures.
method.
When facilities are connected to the system and may cause system imbalance, the system operator or owner is responsible for putting forward regulatory requirements. Usually show
Disturbance facilities are understood as the user's complete facilities (that is, including balanced and unbalanced parts).
The imbalances involved are basically divided into two categories.
* Unbalanced facilities that absorb negative sequence current and generate negative sequence voltage in the power supply system. Such typical facilities include electric arc furnaces, electric
Locomotives (usually connected to the public high-voltage power grid), and various unbalanced three-phase facilities (usually connected to the medium-voltage or low-voltage power grid).
The negative sequence voltage is superimposed on the terminal voltage of the rotating machine, which will generate additional heat loss. Negative sequence voltage will also cause the converter equipment to produce
Generate non-characteristic harmonics (usually the third harmonic in the positive sequence).
* Connected to unbalanced facilities with neutral line system can also absorb zero sequence current. According to the wiring type of the power transformer, zero sequence
The current may or may not be transferred to the power supply system. The zero sequence current flowing in the neutral grounded system will
A zero sequence unbalanced voltage is generated in the phase voltage. Usually it is not by setting the emission limit to control the zero sequence unbalanced voltage,
It is controlled through system design and maintenance. The neutral point is not grounded, or the facilities connected between the phases are not affected by this
The influence of similar zero sequence unbalanced voltage.
This section only provides guidance on how to coordinate the negative sequence voltage between different voltage levels to meet the compatibility level of the power point. Not right
The zero sequence voltage imbalance limits the compatibility level. Compared with the negative sequence voltage imbalance, it is generally considered that the zero sequence voltage imbalance is between different voltage levels.
Inter-coordination is irrelevant. But for the case where the neutral point is effectively grounded via impedance (that is, the ratio of the zero sequence reactance X0 to the positive sequence reactance X1 satisfies 0<
X0/X1<=3), pay attention to this kind of voltage imbalance, especially when the connection method of the transformer allows the zero sequence component to penetrate between the medium voltage and the low voltage.
Transparent occasions.
Note. Since different countries have different delimitations of voltage levels (see 601-01-28 in IEC 60050-601.1985), this section uses system voltage
The following terms.
---Low voltage (LV), refers to Un<=1kV;
---Medium voltage (MV), refers to 1kV \u003cUn<=35kV;
---High voltage (HV), refers to 35kV \u003cUn<=230kV;
--- Extra high voltage (EHV), refers to Un >230kV.
In this section, the function of the system is more important than the nominal voltage. For example, it can be specified that the "planning level" of the high-voltage system used for power distribution is between medium voltage and
Between the planning levels of high-pressure systems.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
How to Buy GB/Z 17625.13-2020
- 1Add to cart. Click the "Buy GB/Z 17625.13-2020" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 120.305-2026 — Microgrids - Part 3-5: Testing for microgrid monitoring, control, and energy management systems
GB/Z 121-2026 — Evaluation index system for sustainable rural development
GB/Z 128-2026 — Course development guide for education about standardization - Fundamentals of quality management
Secure payment via Stripe
Payments accepted
GB/Z 17625.13-2020
$425.00