GB/Z 142-2025Germicidal UV-C irradiation products safety guidelines (English PDF)
杀菌用UV-C辐射产品安全指南
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for GB/Z 142-2025 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Recommended
Issue date
December 3, 2025
Implementation date
December 3, 2025
Scope
GB/Z 142-2025 is the English-translated version of 杀菌用UV-C辐射产品安全指南.
GB/Z 142-2025 — This document provides guidance on radiation safety, ozone safety, and labeling for UV-C radiation products used for sterilization. This document applies to UV-C light sources and UV-C products with an emission wavelength range of 180nm to 280nm.
This document is not applicable to. ---Equipment for which UV-C irradiation safety standards have already been published, such as GB/T 4706.120 and GB/T 4706.45; ---Application environment of UV-C equipment; ---Products that combine UV-C radiation with chemicals and additives; ---Products that do not emit UV-C radiation, such as products that emit UV-A, UV-B, or near-UV radiation; ---Requirements for performance and functional characteristics; ---Requirements to prevent material degradation and damage.
Found what you need?
Document preview — GB/Z 142-2025
National Standard of the People's Republic of China
- ICS
- 29.140.01
- Classification
- C 50
Issued by: State Administration for Market Regulation
Contents
- Preface
- 1 Scope
- 2 Normative References
- 3 Terms and Definitions
- 4 UV-C radiation safety
- 5 Ozone safety 6.
- 6 Identification
- Appendix A (Informative) Examples of Warning Labels for Environments and Products Expected to Have High Concentrations of Ozone (7)
- References
Foreword
This document is a report-type guidance technical document.
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".
Drafting.
This document modifies and adopts IEC PAS 63313:2021 "Position Statement on UV-C Irradiation for Germicidal Purification - Guidelines for UV-C Safety", document type.
The standard has been changed from a publicly available IEC specification to a national standardization guiding technical document of my country.
This document has undergone the following structural adjustments compared to IEC PAS63313:2021.
---Chapter 1 of IEC PAS63313:2021 has been deleted;
---Chapter 1 corresponds to Chapter 2 of IEC PAS 63313:2021;
---Added Chapter 2, Normative References;
---Chapter 3 corresponds to Chapter 7 of IEC PAS 63313:2021;
---Chapter 4 corresponds to Chapter 3 of IEC PAS 63313:2021;
---Chapter 5 corresponds to Chapter 4 of IEC PAS 63313:2021;
---Chapter 6 corresponds to Chapter 5 of IEC PAS 63313:2021;
---Chapter 6 of IEC PAS63313:2021 has been deleted;
---Appendix A corresponds to Appendix B of IEC PAS 63313:2021;
---Appendix A of IEC PAS63313:2021 has been deleted.
The technical differences between this document and IEC PAS63313:2021, and the reasons therefor, are as follows.
---The scope has been expanded with a statement of usage limits (see Chapter 1) to suit my country's national conditions;
---The normative reference GB/T 21092 [see 6.1a)] has been added to adapt to my country's national conditions;
---Table 3, "Other alternative ozone exposure level limits" (see Chapter 4 of IEC PAS 63313:2021), has been deleted to accommodate...
my country's national conditions;
The terms "enclosed enclosure," "controlled area," "irradiance (at a point on the surface)," "partially open enclosure," and "personal protective equipment" have been removed.
"Human presence detection system" and "time protection" (see Chapter 7 of IEC PAS 63313:2021) are needed to adapt to my country's national conditions.
The following editorial changes have been made to this document.
---To align with existing standards, the standard's name has been changed to "Safety Guidelines for UV-C Radiation Products for Sterilization";
---The pending sections in Chapters 3 and 4 have been deleted;
---Adjust the wording of the suspended section in Chapter 5 and move it to the end of section 6.2;
---References have been added.
Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.
This document was proposed by the China National Light Industry Council.
This document is under the jurisdiction of the National Technical Committee on Standardization of Lighting Appliances (SAC/TC224).
1 Scope
This document provides guidance on radiation safety, ozone safety, and labeling for UV-C radiation products used for sterilization.
This document applies to UV-C light sources and UV-C products with an emission wavelength range of 180nm to 280nm.
This document is not applicable to.
---Equipment for which UV-C irradiation safety standards have already been published, such as GB/T 4706.120 and GB/T 4706.45;
---Application environment of UV-C equipment;
---Products that combine UV-C radiation with chemicals and additives;
---Products that do not emit UV-C radiation, such as products that emit UV-A, UV-B, or near-UV radiation;
---Requirements for performance and functional characteristics;
---Requirements to prevent material degradation and damage.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential clauses of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.
This document.
GB/T 21092 Miscellaneous Lamps
3 Terms and Definitions
The following terms and definitions apply to this document.
professional skiledperson A person with relevant education or experience who is able to identify dangers and take appropriate action to reduce injury to themselves and others.
risk.
containment safety guard the protection provided by the cabinet or control area is not a physical component of the UV-C equipment and prevents it from being operated during UV-C equipment operation.
Physical contact, or preventing the operation of the UV-C device during physical contact.
Equipment Safety Guard Enclosed enclosures, partially open enclosures, and/or human presence detection systems.
Note. refers to the physical components of the equipment.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
Referenced standards
Normative references
How to Download GB/Z 142-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 21092-2013 — Miscellaneous lamps
GB/Z 102.17-2026 — Semiconductor devices - Discrete devices - Part 17: Magnetic and capacitive coupler for basic and reinforced insulation
GB/Z 103-2026 — Health informatics - The architecture of internet healthcare service network
Secure payment via Stripe
Payments accepted
GB/Z 142-2025