Valid

GB/T 9489.1-1988Methods for chemical analysis of alundum powder (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for GB/T 9489.1-1988 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

November 28, 2024

Implementation date

June 1, 2025

Scope

GB/T 9489.1-1988 (Methods for chemical analysis of alundum powder) is available as an English-translated PDF.

GB/T 9489.1-1988 — This document describes the content of aluminum oxide, calcium oxide, magnesium oxide, silicon dioxide, iron oxide, titanium dioxide, Determination methods for potassium, sodium oxide, chloride ion, carbon and sulfur, pH value and loss on ignition.

This document is applicable to the chemical analysis of corundum powder with an aluminum oxide content (mass fraction) of not less than 90%.

Found what you need?

Document preview — GB/T 9489.1-1988

National Standard of the People's Republic of China

ICS
91.100.10
Classification
Q 62
Replacing
GB/T 9489-2008

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 General Requirements
  • 5 Determination of calcium oxide, magnesium oxide, silicon dioxide, iron oxide and titanium dioxide by inductively coupled plasma emission spectrometry
  • 5.1 Measurement range
  • 5.2 Principle
  • 5.3 Reagents
  • 5.4 Instruments and Equipment
  • 5.5 Analysis steps
  • 5.6 Analysis results calculation
  • 5.7 Allowable difference
  • 6 Determination of ferric oxide, calcium oxide, magnesium oxide, potassium oxide and sodium oxide by atomic absorption spectrophotometry
  • 6.1 Measurement range
  • 6.2 Principle
  • 6.3 Reagents
  • 6.4 Instruments and Equipment
  • 6.5 Analysis steps
  • 6.6 Analysis results calculation
  • 6.7 Allowable difference
  • 7 Aluminum oxide complex titration-fluoride release method
  • 7.1 Measurement range
  • 7.2 Principle
  • 7.3 Reagents
  • 7.4 Instruments and Equipment
  • 7.5 Analysis steps
  • 7.6 Analysis results calculation
  • 7.7 Allowable Difference
  • 8 Determination of ferric oxide by colorimetric method
  • 8.1 Measurement range
  • 8.2 Principle
  • 8.3 Reagents
  • 8.4 Instruments and Equipment
  • 8.5 Analysis Steps
  • 8.6 Analysis results calculation
  • 8.7 Allowable difference
  • 9 Determination of Silica Colorimetry
  • 9.1 Measurement range
  • 9.2 Principle
  • 9.3 Reagents
  • 9.4 Instruments and Equipment
  • 9.5 Analysis Steps
  • 9.6 Analysis Results Calculation
  • 9.7 Allowable Difference
  • 10 Determination of Titanium Dioxide by Colorimetric Method
  • 10.1 Measurement range
  • 10.2 Principle
  • 10.3 Reagents
  • 10.4 Instruments and Equipment
  • 10.5 Analysis Steps
  • 10.6 Analysis results calculation
  • 10.7 Allowable Difference
  • 11 Determination of Chloride Ion Turbidimetry
  • 11.1 Measurement range
  • 11.2 Principle
  • 11.3 Reagents
  • 11.4 Instruments and Equipment
  • 11.5 Analysis Steps
  • 11.6 Analysis results calculation
  • 11.7 Allowable Difference
  • 12 Determination of Carbon and Sulfur
  • 12.1 Measurement range
  • 12.2 Principle
  • 12.3 Reagents
  • 12.4 Instruments and Equipment
  • 12.5 Analysis Steps
  • 12.6 Allowable Difference
  • 13 Determination of pH value
  • 13.1 Measurement range
  • 13.2 Principle
  • 13.3 Reagents
  • 13.4 Instruments and Equipment
  • 13.5 Analysis Steps
  • 14 Determination of loss on ignition
  • 14.1 Measurement range
  • 14.2 Principle
  • 14.3 Instruments and Equipment
  • 14.4 Analysis Steps
  • 14.5 Analysis results calculation
  • 14.6 Allowable Difference

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting is required.

This document replaces GB/T 9489-2008 "Chemical analysis method of corundum powder". Compared with GB/T 9489-2008, in addition to the structural adjustment in addition to editorial changes, the main technical changes are as follows.

Added "Warning" (see Warning); a) the concentration of "Silicon Dioxide Standard Solution" and the volume of the volumetric flask during the preparation process have been changed (see 5.3.8, 5.3.8 of the 2008 edition); b) the flame type of the elements "Ca, Mg" has been changed (see 6.4.4, 6.4.4 of the 2008 edition); c) Changed the "Test Solution Preparation" in the atomic absorption spectrophotometry (see 6.5.1, 6.5.1 of the 2008 edition); d) the order of adding "borax and sodium carbonate mixed flux" has been changed (see 7.5.1, 9.5.2.1, 7.5.1, 9.5.2.2 of the 2008 edition).

9.5.2.1);

Added the requirement of "storage temperature" of silica standard solution (see 9.5.1, 9.5.2.2); f) the determination range of titanium dioxide colorimetric method has been changed (see 10.1, 10.1 of the 2008 edition); g) the volume of titanium dioxide standard solution to be pipetted in "Drawing the working curve" has been changed (see 10.5.1, 10.5.1 of the 2008 edition). h)

1 Scope

This document describes the content of aluminum oxide, calcium oxide, magnesium oxide, silicon dioxide, iron oxide, titanium dioxide, Determination methods for potassium, sodium oxide, chloride ion, carbon and sulfur, pH value and loss on ignition.

This document is applicable to the chemical analysis of corundum powder with an aluminum oxide content (mass fraction) of not less than 90%.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document.

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies.

in this document.

GB/T 4676 Sampling method for common abrasives GB/T 6682 Specifications and test methods for water used in analytical laboratories GB/T 8170 Rules for rounding off values and expression and determination of limit values

3 Terms and definitions

There are no terms or definitions that require definition in this document.

4 General requirements

4.1 The specifications of water used in solution preparation and analysis should conform to Grade III or above water specified in GB/T 6682.

4.2 Unless otherwise specified, the purity of the reagents used in the determination should be better than analytical grade.

When a standard solution is prepared with a metal, its purity should be better than 99.99%.

4.3 Except for specially specified solvents, all solutions used in analysis are aqueous solutions.

4.4 When conducting the "constant weight" test, the burning or drying, taking out, drying, cooling, and weighing steps should be repeated at the same temperature.

Continue until the difference between the two weighings is no more than 0.000 2 g.

4.5 The concentration of the standard titration solution is expressed as c(A)=mol/L or T(B)/(A)=mg/mL. When calibrating its concentration, Carry out more than three determinations and conduct blank test comparison. The relative error of the concentration obtained should not be greater than 0.20%. The arithmetic mean of the results is taken.

And rounded to 4 decimal places.

4.6 When preparing and storing reagent solutions, reagents that are corrosive to glass should be stored in plastic containers, and reagents that are easily decomposed should be stored in Store in brown containers and indicate storage precautions and storage time.

4.7 A parallel blank test should be carried out for each test, and the analytical results should be corrected based on the blank test results.

4.8 The samples shall be sampled and divided according to GB/T 4676, and then ground with a corundum mortar to a particle size of no more than 75 µm.

Mix well, put into sample bag, dry in electric drying oven at 105°C~110°C for 1 h~2 h, take out, put into desiccator and cool to room temperature for use.

The mass of the analytical sample should not be less than 20 g.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 9489.1-1988

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 9489.1-1988