Valid

GB/T 9109.5-2017Petroleum and liquid petroleum products dynamic measurement -- Part 5: Calculation of oil quantities (English PDF)

Also coversGBT9109.5-2017

Open the GB/T 9109.5-2017 preview as PDF

Preview — first pages of GB/T 9109.5-2017

This is a limited preview

Buy now to download the full PDF

Issued by

MOHURD; AQSIQ

Level / Type

National · Recommended

Issue date

May 12, 2017

Implementation date

December 1, 2017

Scope

GB/T 9109.5-2017 (Petroleum and liquid petroleum products dynamic measurement -- Part 5: Calculation of oil quantities) is available as an English-translated PDF.

GB/T 9109.5-2017 — This Part of GB/T 9109 specifies the oil quantity calculation method for dynamic measurement of petroleum and liquid petroleum products (hereinafter referred to as oil); defines the terms and symbols used in the dynamic measurement of oil products; gives the weight in air under different measurement methods using different measuring instruments, OR the formula for calculating the oil quantity under standard reference conditions; provides the relevant measurement parameters, correction factors, corresponding formulas and tables, which are involved in the calculation of the oil quantity. This Part only applies to the dynamic measurement of single-phase oil products. This Part does not apply to the oil quantity calculation of liquefied petroleum gas and stable light hydrocarbons.

Document preview — GB/T 9109.5-2017

National Standard of the People's Republic of China

Issued by: MOHURD; AQSIQ

Contents

  • Foreword3
  • Introduction5
  • 1 Scope6
  • 2 Normative references6
  • 3 Terms, definitions, symbols7
  • 4 Significant digits of measurement parameters and numerical rounding10
  • 5 Preparation of basic data12
  • 6 Fuel quantity calculation formula13
  • 7 Measurement bills19
  • 8 Calculation method of oil quantity22
  • Appendix A (Normative) Measurement data reading rules32
  • Appendix B (Normative) Calculation method of oil volumetric pressure correction factor35
  • Appendix C (Normative) Hydrocarbon compressibility factor37
  • Appendix D (Normative) Conversion of petroleum and liquid petroleum products from 20 °C density to 15 °C density38
  • Appendix E (Informative) Air buoyancy correction factor table40
  • Appendix F (Informative) Format and content of measurement bills41
  • Appendix G (Normative) Conversion factor from 15 °C density to barrel/t42

1 Scope

This Part of GB/T 9109 specifies the oil quantity calculation method for dynamic measurement of petroleum and liquid petroleum products (hereinafter referred to as oil);

defines the terms and symbols used in the dynamic measurement of oil products; gives the weight in air under different measurement methods using different measuring instruments, OR the formula for calculating the oil quantity under standard reference conditions; provides the relevant measurement parameters, correction factors, corresponding formulas and tables, which are involved in the calculation of the oil quantity.

This Part only applies to the dynamic measurement of single-phase oil products.

This Part does not apply to the oil quantity calculation of liquefied petroleum gas and stable light hydrocarbons.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document;

for the undated documents, only the latest version (including all the amendments) is applicable to this standard.

GB/T 260 Test method for water in petroleum products - Distillation method

GB/T 1884 Crude petroleum and liquid petroleum products - Laboratory determination of density - Hydrometer method

GB/T 1885-1998 Petroleum measurement tables

GB/T 4756 Method for manual sampling of petroleum liquids

GB/T 6531 Crude petroleum and fuel oils - Determination of sediment - Extraction method

3 Terms, definitions, symbols

The following terms, definitions, symbols apply to this document.

3.1 Terms and definitions

3.1.1 Indicated volume or mass During measurement, the oil value displayed by the flowmeter counter or other display unit, including water and sediment transported through the flowmeter.

3.1.2 Total observed volume or mass The indicated volume or mass as multiplied by the flowmeter factor corresponding to the oil product and its flow rate. This value is not corrected for temperature and pressure.

3.2 Symbols

See Table 1.

4 Significant digits of measurement parameters and

numerical rounding

4.1 Effective digits of measurement parameters

4.1.1 Depending on the density reading and density conversion, keep 1 decimal place, that is, 0.1 kg/m3.

4.1.2 Measurement of moisture content in oil (distillation method), round to two

decimal places 0.01%.

4.2 Numerical rounding off

4.2.1 The numerical rounding off method shall comply with the provisions of GB/T

8170.In most cases, the number of decimal places used is affected by the data source.

In the absence of other limiting factors, rounding off shall be performed, according to the decimal places specified in Table 2.

4.2.2 MF, Ctl, Cpl, Csw, Fa shall be rounded to the fourth decimal place, in accordance

with the provisions of GB/T 8170.

4.2.3 The oil quantity settlement value follows the requirements of GB/T 8170; the

volume value is rounded to 0.001 m3; the mass value is rounded to 0.001 t.

Example.

5 Preparation of basic data

5.1 Overview

In order to obtain accurate results of the oil quantity (volume or mass), which is measured by the flowmeter, it shall first ensure that the basic data for calculating the oil quantity (such as the indicated volume of the flowmeter, measuring temperature, measuring pressure, density, moisture content, etc.) are obtained, in accordance with the standard method (or procedure) (see Appendix A);

5.2 Flowmeter

The accuracy level of flowmeters, which are used for trade transfer measurement, shall be no less than level 0.2.

5.3 Measuring temperature

The measurement temperature of oil products shall be measured or recorded, using a mercury-in-glass thermometer, which has a graduation value of not less than 0.2 °C, OR other types of temperature transmitters, which are not lower than the same accuracy requirements.

5.4 Measuring pressure

Oil measuring pressure shall be measured or recorded, using a 0.4 grade pressure gauge or other types of pressure transmitters, which are not lower than the same accuracy requirements.

5.5 Sampling

Oil sampling shall be carried out, in accordance with the requirements specified in

GB/T 4756 or GB/T 27867.

5.6 Density

5.7 Moisture content

It is measured according to GB/T 8929; it can also be measured according to GB/T 260 and GB/T 6531.

6 Fuel quantity calculation formula

6.1 Method overview

6.1.1 The settlement basis for oil trade is divided into weight or volume in the air.

Therefore, oil quantity calculation is also divided into two methods.

6.1.3 Taking the volume-weight method as an example (flowmeter factor method), during the measurement period, record the indicated volume (Vt),

6.2 Volume settlement

6.2.1 Calculation formula
6.2.2 Calculation steps
6.2.2.1 Determine Vt

The indicated volume, which is measured by the flowmeter under measuring pressure, is calculated according to formula (4).

If the flowmeter uses K factor, the indicated volume, which is measured by the flowmeter under metering pressure, is calculated according to formula (5).

6.2.2.4 Determine Cpl

If the reading of the flowmeter has been corrected by pressure compensation, OR the impact at low pressure is less than 0.01%, then set Cpl = 1.0000; otherwise, calculate it according to formula (6).

6.2.2.6 Determine Vsw

Vsw is calculated according to formula (8).

6.2.2.7 Calculation formula of mass flowmeter volume

Vgs is calculated according to formula (9).

6.3 Settlement based on weight in air

It is divided into three types according to the measurement method. One is a flowmeter based on volume measurement coupled with a glass float meter.

6.3.1 Measurement method of flowmeter coupled with glass float meter
6.3.2 Measurement method of flowmeter with online density meter
6.3.3 Mass flowmeter measurement method
6.3.3.2 Calculation steps
6.3.4 Calculation formula of oil moisture content

msw is calculated according to formula (26).

7 Measurement bills

7.1 Measurement data requirements

7.1.1 Use standardized conditions and prescribed calculation procedures, to obtain

consistent calculation results from the same set of oil quantity data; standardize the calculation rules for oil quantity (volume or mass).

7.1.3 Ensure that copies of measurement bills (including faxes) are clearly written, unless the relevant parties agree to make modification or deletion on the measurement bills.

7.1.4 If there is an error in the measurement bill, the bill shall be marked "invalid" and

a new bill shall be prepared.

7.3 Format and content of measurement bills

Please refer to Appendix F for the format and content of the measurement bill.

8 Calculation method of oil quantity

8.1 Calculation of standard volume of oil products

8.1.2 Calculation of oil quantity using basic error method

According to formula (1), calculate the net standard volume of oil.

8.1.3 Calculation of oil quantity using flowmeter factor method

8.2 Calculation of oil quality and weight in air

8.2.1 Measurement example

For continuous measurement of long-distance crude oil pipelines, a flowmeter with a glass float meter is used to manually measure the density; meanwhile the flowmeter factor is used, to calculate the weight of oil in the air. The measured values of the metrological parameters are as shown in Table 7.

8.2.4 Temperature correction factor Ctl

From t = 37.75 °C and rho20 = 845.3 kg/m3, see Table 8.

8.2.5 Pressure correction factor Cpl

8.4 Calculation of oil products measured using K factor method

Diesel at a metering station is measured using a turbine flowmeter. The measured values and calculation procedures of the measurement parameters are as shown in Table 11.

8.4.5 Deduction of moisture content

The measured oil is trade transfer oil, so the moisture content shall be deducted.

8.4.6 Calculation of volume under different standard reference conditions
8.4.6.3 Volume calculation at 60 °F and 101.325 kPa

The original measurement data and measurement procedures are as shown in Table 14.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 260 · GB/T 1884 · GB/T 1885-1998 · GB/T 4756 · GB/T 6531

How to Buy GB/T 9109.5-2017

  1. 1Add to cart. Click the "Buy GB/T 9109.5-2017" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 9109.5-2017

$480.00

$410.00for partners