Valid

GB/T 8704.3-2009Ferrovanadium - Determination of sulfur content - The infrared absorption method and the combustion-neutralization titration method (English PDF)

钒铁 硫含量的测定 红外线吸收法及燃烧中和滴定法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 8704.3-2009 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 15, 2009

Implementation date

April 1, 2010

Scope

GB/T 8704.3-2009 is the English-translated version of 钒铁 硫含量的测定 红外线吸收法及燃烧中和滴定法.

GB/T 8704.3-2009 is the Chinese national method for the sulfur content of ferrovanadium, by infrared absorption and by combustion-neutralization titration, over a mass fraction of 0.005% to 0.120%.

In the infrared method the specimen is burnt in flowing oxygen in a high-frequency induction furnace and the sulfur dioxide produced goes to the measuring chamber of a sulfur infrared absorption analyser of 0.1 x 10(-6) sensitivity, the absorbed energy at a specific wavelength being proportional to the sulfur concentration.

The reagents and materials are those that keep the blank low: acetone, anhydrous magnesium perchlorate, soda asbestos, glass wool, tungsten and tin particles below 0.0002% sulfur, pure iron above 99.8% purity, oxygen above 99.95% purity and porcelain crucibles ignited above 1200 °C. Sampling follows GB/T 4010.

Issued on 15 July 2009, it replaces GB/T 8704.3-1997 and has applied since 1 April 2010.

Found what you need?

Document preview — GB/T 8704.3-2009

National Standard of the People's Republic of China

ICS
77.100
Classification
H 11
Replacing
GB/T 8704.3-1997

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Method One. The infrared absorption method

Foreword

This Part replaces GB/T 8704.3-1997 "determination of sulfur content for chemical analysis of ferrovanadium The infrared absorption method and combustion - neutralization titration method." This portion of the GB/T 8704.3-1997 comparison, the main changes are.

--- The method of one of the sample weight 0.500g, 0.200g two tranches adjusted to a file 0.200g;

--- The method of one of the iron from the flux amount was adjusted to 0.50g 0.20g;

--- The method of one of the first, second gear allows for the consolidation difference sulfur content of 0.005% to 0.015%, 0.002% allowable difference;

--- The second method of determination by the scope of < 0.120% to 0.005% and 0.120%.

1 Scope

This section GB/T 8704 regulations using infrared absorption method and combustion - neutralization titration method for the determination of vanadium iron sulfur content.

This section applies to the determination of vanadium iron sulfur content. Measurement range (mass fraction). 0.005% and 0.120%.

2 Normative references

The following documents contain provisions cited by GB/T 8704 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 4010 alloy chemical analysis and preparation of samples

3 Method One. The infrared absorption method

3.1 Principle

The sample is heated in a high frequency induction furnace combustion oxygen flow generated by the oxygen contained sulfur dioxide infrared analyzer to the measuring chamber dioxide A sulfur absorbing specific wavelengths of infrared energy, which is proportional to the absorbed energy and the concentration of sulfur, based on the detection unit accepts the change in energy can be measured sulfur content.

3.2 Reagents and materials

3.2.1 acetone. sulfur content of the residue after evaporation is less than 0.0005%.

3.2.2 Magnesium perchlorate, anhydrous, granular.

3.2.3 Asbestos caustic soda, granular.

3.2.4 Glass wool.

3.2.5 tungsten particles. sulfur content of less than 0.0002%, particle size 0.8mm ~ 1.4mm.

3.2.6 tin particles. sulfur content of less than 0.0002%, particle size 0.4mm ~ 0.8mm. If necessary, apply acetone (3.2.1) clean the surface and in the room Temperature and dried.

3.2.7 pure iron. purity of greater than 99.8%, a sulfur content of less than 0.0002%, particle size 0.8mm ~ 1.6mm.

3.2.8 Oxygen. The purity of more than 99.95%, if other levels of oxygen to obtain a low and consistent blank, can also be used.

3.2.9 Power Source gas. nitrogen or compressed air, which contaminants (oil and water) content of less than 0.5%.

3.2.10 porcelain crucible. diameter × height, 23mm × 23mm or 25mm × 25mm, and above 1200 °C high temperature furnace 4h or by burning oxygen burning to blank the lowest value.

3.2.11 Crucible tongs.

3.3 Instruments and equipment

3.3.1 Sulphur infrared absorption analyzer (sensitivity of 0.1 x 10^-6), which means as shown in Figure 1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 8704.3

EditionTitleRevisionStatus
GB/T 8704.3-2009Ferrovanadium - Determination of sulfur content - The infrared absorption method and the combustion-neutralization titration methodcurrent editionCurrent
GB/T 8704.3-1997Ferrovanadium - Determination of sulfur content - The infrared absorption method and the combustion-neutralization titration methodprevious editionSuperseded

This page sells the current edition, GB/T 8704.3-2009. Earlier editions are listed for reference only.

How to Download GB/T 8704.3-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 8704.3-2009