GB/T 8647.8-2006The methods for chemical analysis of nickel -- Determination of sulphur content -- Infra-red absorption method after high frequency induction furnace combustion (English PDF)
镍化学分析方法 硫量的测定
This is a limited preview
Buy now to download the full PDF (8 pages)
Need quotation for your management?
Get a formal quotation for GB/T 8647.8-2006 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Recommended
Issue date
September 26, 2006
Implementation date
February 1, 2007
Scope
GB/T 8647.8-2006 is the English-translated version of 镍化学分析方法 硫量的测定.
GB/T 8647.8-2006 - This Part specifies the method for the determination of sulphur content in nickel. This Part is applicable to the determination of sulphur content in nickel. Determination range: 0.0010%~0.050%.
Found what you need?
Document preview — GB/T 8647.8-2006
National Standard of the People's Republic of China
- ICS
- 77.040.30
- Classification
- H 13
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword...3
- 1 Scope...5
- 2 Method summary...5
- 3 Reagents...5
- 4 Instruments...6
- 5 Analysis steps...6
- 6 Precision...7
- 7 Quality assurance and control...8
Foreword
GB/T 8647 "The methods for chemical analysis of nickel" is divided into the following
10 parts:
GB/T 8647.1, The methods for chemical analysis of nickel -- Determination of iron
content -- Sulfosalicylic acid spectrophotometric method
GB/T 8647.2, The methods for chemical analysis of nickel -- Determination of
aluminium content -- Electrothermal atomic absorption spectrometric method
GB/T 8647.3, The methods for chemical analysis of nickel -- Determination of silicon
content -- Molybdenum blue spectrophotometric method
GB/T 8647.4, The methods for chemical analysis of nickel -- Determination of
phosphorous content -- Molybdenum blue spectrophotometric method
GB/T 8647.5, The methods for chemical analysis of nickel -- Determination of
magnesium content -- Flame atomic absorption spectrometric method
GB/T 8647.6, The methods for chemical analysis of nickel -- Determination of cadmium,
cobalt, copper, manganese, lead and zinc contents -- Flame atomic absorption
spectrometric method
GB/T 8647.7, The methods for chemical analysis of nickel -- Determination of arsenic
antimony bismuth tin and lead contents -- Electrothermal atomic absorption
spectrometric method
GB/T 8647.8, The methods for chemical analysis of nickel -- Determination of sulphur
content -- Infra-red absorption method after high frequency induction furnace
combustion
GB/T 8647.9, The methods for chemical analysis of nickel -- Determination of carbon
content -- Infra-red absorption method after high frequency induction furnace
combustion
GB/T 8647.10, The methods for chemical analysis of nickel -- Determination of arsenic
cadmium lead zinc antimony bismuth tin cobalt copper manganese magnesium silicon
aluminium iron contents -- Atomic emission spectrometric method
This is Part 8.
This Part is not equivalent to ISO 7526-1985 "Nickel, ferronickel and nickel alloys --
Determination of sulphur content -- Infra-red absorption method after induction furnace
combustion".
The methods for chemical analysis of nickel - Determination
of sulphur content - Infra-red absorption method after high
frequency induction furnace combustion
1 Scope
This Part specifies the method for the determination of sulphur content in nickel.
This Part is applicable to the determination of sulphur content in nickel. Determination
range: 0.0010%~0.050%.
2 Method summary
In the presence of flux, oxygen flow is introduced into the high-frequency induction
furnace to make the test material burn at high temperature. Sulfur generates sulfur
dioxide gas and enters the infrared absorption cell. The instrument automatically
measures its absorption of infrared energy, calculates and displays the results.
3 Reagents
3.1 Anhydrous magnesium perchlorate [Mg(ClO4)2].
3.2 Caustic soda asbestos.
3.3 Glass wool.
3.4 Cotton wool.
3.5 Platinum-coated silicone.
3.6 Flux: low sulfur tungsten, tin: W+Sn (1 g+0.2 g~0.25 g).
3.7 Crucible
Ceramic crucible (Phi24 mm×24 mm). Before use, it should be burned in a furnace with
air or oxygen at a temperature greater than 1100°C for 1 h~1.5 h. Take it out and place
it in a non-oiled desiccator to cool it for use (valid for two days).
3.8 Standard steel sample: sulfur content 0.002%~0.06%.
3.9 Steel standard sample or pure iron standard sample: sulfur content is about 0.002%.
within the error range.
NOTE: When selecting a standard steel sample, the sulfur content should be greater than the sulfur
content of the specimen being tested.
5.4 Calibration blanks
5.4.1 Weigh 0.500 g of standard steel sample (3.9) and place it in a crucible (3.7). Add
flux (3.6).
5.4.2 Place the crucible on the support of the furnace. Raise it to the burning position.
Follow the "automatic" blank calibration steps in the instrument manual. Repeat for 3
~ 5 steel samples to obtain an average result with good reproducibility. Deduct the mass
fraction of sulfur in the standard steel sample by "automatic" blank calibration. The
value is expressed in %. The blank value obtained is stored in the computer (blank value
should be < 0.0005%).
5.4.3 Repeat the test of the standard steel sample according to 5.3. The test result should
be stable within the error range. Select another standard sample with the same sulfur
content as the sample being tested for retest.
5.5 Determination
5.5.1 Weigh 0.500 g of specimen and place it in a crucible (3.7). Add flux (3.6).
5.5.2 Place the crucible on the support of the furnace. Raise it to the combustion position.
Follow the "automatic" analysis steps in the instrument manual. The instrument
automatically deducts the blank value and displays and prints the mass fraction of sulfur.
The value is expressed in %.
6 Precision
6.1 Repeatability limit
For the determination values of two independent test results obtained under
repeatability conditions, the absolute difference between the two test results does not
exceed the repeatability limit (r) within the range of the average values given below.
The case where the repeatability limit (r) is exceeded does not exceed 5%. The intra-
laboratory repeatability is listed in Table 2.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.
Referenced standards
Cited by
- NB/T 20009.24-2015Welding material for pressurized water reactor nuclear power plants - Part 24: Nickel alloy covered electrodes for safety-related components
- NB/T 20009.28-2015Welding material for pressurized water reactor nuclear power plants - Part 28: Nickel alloy welding electrodes for safety-related components
- YS/T 889-2013Reproduced nickel powder for powder metallurgy
- GB/T 26032-2010Evaporated nickel material
How to Download GB/T 8647.8-2006
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8647.1-2006 — The methods for chemical analysis of nickel - Determination of iron content - Sulfosalicylic acid spectrophotometric method
GB/T 8647.10-2006 — The methods for chemical analysis of nickel - Determination of arsenic,cadmium,lead,zinc,antimony,bismuth,tin,cobalt,copper,manganese,magnesium,silicon,aluminium,iron contents - Atomic emission spectrometric method
GB/T 8647.11-2019 — Methods for chemical analysis of nickel-Part 11: Determination of magnesium,aluminum,manganese,cobalt,copper,zinc,cadmium,tin,antimony,lead,bismuth contents-Inductively coupled plasma mass spectrometry
Secure payment via Stripe
Payments accepted
GB/T 8647.8-2006