Scope

GB/T 7260.503-2020 (Uninterruptible power systems (UPS) - Part 5-3: DC output UPS. Performance and test requirements) is available as an English-translated PDF.

GB/T 7260.503-2020 — This part of GB/T 7260 specifies electronic DC output uninterruptible power supply systems suitable for movable, non-movable and fixed installations: System (DC uninterruptible power supply) performance and test requirements: This type of DC uninterruptible power supply has the following characteristics: ---Powered by an AC voltage source not exceeding 1000V; ---Provide a DC output voltage not exceeding 1500V; ---Contains an energy storage device; ---The main function is to ensure the continuous DC power supply to the load: This section specifies the performance and test requirements of a complete DC uninterruptible power supply system (rather than a single DC uninterruptible power supply functional unit): begging: The performance and test requirements of a single DC uninterruptible power supply functional unit can be found in the IEC publications mentioned in the references, which are in line with this part: The points are not contradictory: The power range of DC uninterruptible power supply ranges from less than one hundred watts to megawatts, which can meet the requirements of various loads on power availability and power quality: Claim: See Appendix A and Appendix B for information about typical DC uninterruptible power supply configurations and topologies: This part also includes components related to circuit breakers, disconnect switches, and interconnect switches (if any) integrated in the DC uninterruptible power supply: Performance and test requirements: These components interact with other functional units of the DC uninterruptible power supply to maintain continuous load power: This section does not include: ---Traditional AC input switchboard and related switches; ---Traditional DC distribution boards and related switches; ---Traditional AC uninterruptible power supply covered by IEC 62040-3; --- Low-voltage DC power supply equipment covered by specific product standards (e:g: IEC 61204) and specific product standards (e:g: ITU communication standards) Quasi) covered equipment; ---The output voltage is derived from the system of rotating electrical machines: Note 1: This section believes that the uninterruptible power supply system is mainly used for the power supply of information technology (IT) equipment: Therefore, the DC uninterruptible power supply specified in this section The output characteristics are also designed to ensure compatibility with the requirements of IT equipment: This point is subject to the limit range declared by the manufacturer, including the steady-state and transient voltage Changing requirements and requirements for power supply to IT equipment with both resistive and constant power load characteristics: Note 2: The test load specified in this section simulates both resistive and constant power load characteristics: The application of this type of load is to verify the Design and performance, and minimize the complexity and energy consumption in the test process:

Document preview — GB/T 7260.503-2020

National Standard of the People's Republic of China

ICS
29.200
Classification
K 85

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • 1 Scope1
  • 2 Normative references1
  • 3 Terms and definitions2
  • 3:1 Overview2
  • 3:2 System and component definition3
  • 3:3 Performance of systems and components5
  • 3:4 General rating6
  • 3:5 Input value9
  • 3:6 Output value10
  • 4 Environmental conditions11
  • 4:1 Test environment11
  • 4:2 Normal environmental conditions11
  • 4:3 Abnormal environmental conditions12
  • 5 Electrical conditions, performance and declared values13
  • 5:1 Overview13
  • 5:2 Input of DC uninterruptible power supply13
  • 5:3 Output of DC uninterruptible power supply15
  • 5:4 Energy storage17
  • 5:5 DC uninterruptible power switch18
  • 5:6 Communication line18
  • 6 DC uninterruptible power supply test18
  • 6:1 Overview18
  • 6:2 Routine test procedures21
  • 6:3 Field test procedures22
  • 6:4 Type test procedure (electrical)22
  • 6:5 Type test procedure (environment)28
  • 6:6 DC uninterruptible power supply functional unit test (not as a complete DC uninterruptible power supply test)30
  • Appendix A (informative appendix) DC uninterruptible power supply configuration32
  • Appendix B (informative appendix) DC uninterruptible power supply topology36
  • Appendix C (informative appendix) Buyer Specification Guide38
  • Appendix D (Normative Appendix) Input mains failure test method41
  • Appendix E (Informative Appendix) Dynamic Output Performance Measurement Technology42
  • Appendix F (Normative appendix) DC uninterruptible power supply efficiency measurement method43
  • Appendix G (informative appendix) Climatic test45
  • References48

Foreword

GB/T 7260 "Uninterruptible Power System (UPS)" has or plans to publish the following parts:

---Part 1-1: General regulations and safety requirements of UPS used in the area where the operator touches;

---Part 1-2: General regulations and safety requirements for UPS used in restricted areas;

---Part 2: Electromagnetic compatibility (EMC) requirements;

---Part 3: Methods and test requirements for determining performance;

---Part 4: Environmental requirements and reports;

---Part 5-3: DC output UPS performance and test requirements:

This part is part 5-3 of GB/T 7260:

This section was drafted in accordance with the rules given in GB/T 1:1-2009:

The translation method used in this part is equivalent to IEC 62040-5-3:2016 ``Uninterruptible Power System (UPS) Part 5-3: DC Output

UPS performance and test requirements:

The Chinese documents that have a consistent correspondence with the international documents cited in this section are as follows:

---GB/T 2423:1-2008 Environmental testing of electric and electronic products Part 2: Test method Test A: Low temperature

(IEC 60068-2-1:2007, IDT)

---GB/T 2423:2-2008 Environmental testing of electric and electronic products Part 2: Test method Test B: High temperature

(IEC 60068-2-2:2007, IDT)

---GB/T 2423:3-2016 Environmental Test Part 2: Test Method Test Cab: Constant Humidity Test (IEC 60068-

2-78:2012, IDT)

---GB/T 2423:5-2019 Environmental Test Part 2: Test Method Test Ea and Guideline: Impact (IEC 60068-2-

27:2008, IDT)

---GB/T 2423:7-2018 Environmental test Part 2: Test method Test Ec: Impact caused by rough operation (main

For equipment type samples) (IEC 60068-2-31:2008, IDT)

---GB/T 3785:1-2010 Electroacoustic Sound Level Meter Part 1: Specification (IEC 61672-1:2002, IDT)

---GB/T 3859:1-2013 General requirements for semiconductor converters and power grid commutated converters Part 1-1: Basic requirements

Fan (IEC 60146-1-1:2009, MOD)

---GB/T 7260:1-2008 Uninterruptible power supply equipment (UPS) Part 1-1: UPS used in the operator's reach

General regulations and safety requirements (IEC 62040-1-1:2002, MOD)

---GB/T 7260:2-2009 Uninterruptible power supply equipment (UPS) Part 2: Electromagnetic compatibility (EMC) requirements (IEC 62040-

2:2005, IDT)

---GB/T 18313-2001 Acoustics information technology equipment and communication equipment air noise measurement (idtISO 7779:1999)

---GB/T 20159:3-2011 Environmental condition classification The relationship between environmental condition classification and environmental test and conversion guide

Fixed use in places with weather protection (IEC TR60721-4-3:2003, IDT)

This part was proposed by China Electrical Equipment Industry Association:

This part is under the jurisdiction of the National Power Electronic System and Equipment Standardization Technical Committee (SAC/TC60):

Drafting organizations of this section: Kehua Hengsheng Co:, Ltd:, Guangdong Zhicheng Champion Group Co:, Ltd:, Xi'an Power Electronics Technology Research Institute,

Schneider Electric Information Technology (China) Co:, Ltd:, Wenzhou University, Huawei Technologies Co:, Ltd:, Aerospace Burke (Guangdong) Technology Co:, Ltd:, China

University of Science and Technology of China, China Mobile Communications Group Design Institute Co:, Ltd:, Renault (Changzhou) Electronics Co:, Ltd:, Xiamen Avida Electronics Co:, Ltd:

Company, China Academy of Information and Communications Technology, Hangzhou Borui Electronic Technology Co:, Ltd:, Hunan University, Xiankong Strapdown Electric Co:, Ltd:, ZTE

Communications Co:, Ltd:, Jiangsu Hongwei Technology Co:, Ltd:, Yiwu Yuantai Intelligent Technology Co:, Ltd:, Spallation Neutron Source Science Center,

Xi'an Libeian Intelligent Technology Co:, Ltd:, Dongguan Electronic Information Industry Association, Zhuhai Titan Technology Co:, Ltd:

1 Scope

This part of GB/T 7260 specifies electronic DC output uninterruptible power supply systems suitable for movable, non-movable and fixed installations:

System (DC uninterruptible power supply) performance and test requirements: This type of DC uninterruptible power supply has the following characteristics:

---Powered by an AC voltage source not exceeding 1000V;

---Provide a DC output voltage not exceeding 1500V;

---Contains an energy storage device;

---The main function is to ensure the continuous DC power supply to the load:

This section specifies the performance and test requirements of a complete DC uninterruptible power supply system (rather than a single DC uninterruptible power supply functional unit):

begging: The performance and test requirements of a single DC uninterruptible power supply functional unit can be found in the IEC publications mentioned in the references, which are in line with this part:

The points are not contradictory:

The power range of DC uninterruptible power supply ranges from less than one hundred watts to megawatts, which can meet the requirements of various loads on power availability and power quality:

Claim: See Appendix A and Appendix B for information about typical DC uninterruptible power supply configurations and topologies:

This part also includes components related to circuit breakers, disconnect switches, and interconnect switches (if any) integrated in the DC uninterruptible power supply:

Performance and test requirements: These components interact with other functional units of the DC uninterruptible power supply to maintain continuous load power:

This section does not include:

---Traditional AC input switchboard and related switches;

---Traditional DC distribution boards and related switches;

---Traditional AC uninterruptible power supply covered by IEC 62040-3;

--- Low-voltage DC power supply equipment covered by specific product standards (e:g: IEC 61204) and specific product standards (e:g: ITU communication standards)

Quasi) covered equipment;

---The output voltage is derived from the system of rotating electrical machines:

Note 1: This section believes that the uninterruptible power supply system is mainly used for the power supply of information technology (IT) equipment: Therefore, the DC uninterruptible power supply specified in this section

The output characteristics are also designed to ensure compatibility with the requirements of IT equipment: This point is subject to the limit range declared by the manufacturer, including the steady-state and transient voltage

Changing requirements and requirements for power supply to IT equipment with both resistive and constant power load characteristics:

Note 2: The test load specified in this section simulates both resistive and constant power load characteristics: The application of this type of load is to verify the

Design and performance, and minimize the complexity and energy consumption in the test process:

2 Normative references

The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article

Pieces: For undated references, the latest version (including all amendments) applies to this document:

GB/T 3859:4-2004 Semiconductor converter includes direct DC converter semiconductor self-commutated converter (IEC 60146-2:

1999, IDT)

GB/T 16895:1-2008 Low-voltage electrical installations Part 1: Basic principles, general characteristics assessment and definitions (IEC 60364-1:

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 3859 · IEC 60146 · GB/T 16895 · IEC 60364

How to Buy GB/T 7260.503-2020

  1. 1Add to cart. Click the "Buy GB/T 7260.503-2020" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 7260.503-2020

$680.00

$580.00for partners