Scope
GB/T 7165.4-2008 is the English-translated version of 气态排出流(放射性)活度连续监测设备 第4部分:放射性碘监测仪的特殊要求.
GB/T 7165.4-2008 — GB/T 7165 This section applies to all forms of radioactive iodine for the same time, delay or sequentially measuring device.
When the flow of discharge when sampling measurements, attached to the aerosol iodine generally consists of pre-filter is collected, and then analyzed separately in the laboratory, to mention for complete measurement.
Radioactive iodine monitors should have the following features. --- Measuring gaseous exhaust stream total activity volume activity of iodine and iodine compounds and emissions of radioactive iodine; --- When the radioactivity concentration or total activity iodine or an iodine compound exceeds a preset threshold, the start alarm signal.
Such devices will be measured in the presence of gaseous effluents of radionuclides other activity, including natural radionuclides. Its He radionuclide screening when measuring low levels of radioactive iodine is very important.
The chimney or ventilation pipe, this section takes into account both the use of activated carbon as iodine sampling medium, but also consider the direct iodine measuring.
The purpose of this section is to set out the provisions of Chapter 4 iodine monitors specific standard requirements, including technical characteristics and general test conditions, and give Examples of possible approaches.
GB/T 7165.1-2005 in the general requirements for such equipment, technical characteristics, test methods, radiation characteristics, electrical characteristics, mechanical Mechanical characteristics, security features and environmental characteristics. Unless otherwise noted, these requirements apply to this section.
Found what you need?
Document preview — GB/T 7165.4-2008
National Standard of the People's Republic of China
- ICS
- 13.280
- Classification
- F 84
- Replacing
- GB/T 7165.4-1989
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
Foreword
This part of GB/T 7165 "gaseous effluents (radioactive) activity continuous monitoring equipment" Part 4. The total includes a lower standard Column five parts.
GB/T 7165.1 "gaseous effluents (radioactive) activity continuous monitoring equipment - Part 1. General requirements";
GB/T 7165.2 "gaseous effluents (radioactivity) Equipment for continuous monitoring activity - Part 2. radioactive aerosols (including transuranic aerosols Glue) monitor special requirements ";
GB/T 7165.3 "gaseous effluents (radioactive) activity continuous monitoring equipment - Part 3. radioactive noble gas monitor special Claim";
GB/T 7165.4 "gaseous effluents (radioactive) activity continuous monitoring equipment - Part 4. radioactive iodine monitors special requirements";
GB/T 7165.5 "gaseous effluents (radioactive) activity continuous monitoring equipment - Part 5. Particular requirements for tritium monitors." this section is amended to GB/T 7165.4-1989's.
This section identical with IEC 60761-4:2002 "gaseous effluents (radioactive) activity continuous monitoring equipment - Part 4. radioactive iodine Particular requirements for monitors "(in English).
For ease of use, this section made the following editorial changes.
--- Delete the original International Standards and Introduction;
--- With a decimal point instead of the original international standard decimal point ",". ",";
--- Will be in "2 Normative references" existing national standards and industry standards relevant international standards to our standards (in GB/T 2423.5 instead of IEC 60028-2-27. 1987, with GB/T 7165.1-2005 instead of IEC 60761-2:2002, in order to GB/T 17626 instead of IEC 61000, GB 9254-1998 to replace the IEC/CISPR22.1997);
--- Retain only the contents of the current used in the voltage and frequency of the AC power supply.
This Part replaces GB/T 7165.4-1989 "gaseous effluents (radioactive) activity continuously monitoring Part IV. iodine monitors Particular requirements. " Section compared with the GB/T 7165.4-1989 The main changes are as follows.
--- Iodine monitor type, and an increase in the chimney pipe direct measurement of iodine monitors;
--- Sampling and detection devices, increasing the demands on the pump;
--- Select the type of reference source added to the reference gas source, the source added for special provisions;
--- Standard test conditions were amended to increase the flow, electrostatic field, radon progeny and chemical pollution standard test conditions, modify the set
--- Linearity requirements inherent relative error, revised from 20% to 10%;
--- Indication of the duration of the stability test requirements, as amended by the 500h 100h;
--- Alarm threshold stability test time required by the revised 500h 100h, drift alarm threshold requirement from 20% to 5%;
--- Meter indoor ambient temperature requirements by the 10 °C ~ 50 °C revised to 10 °C ~ 35 °C;
--- Relative humidity test temperature from 30 °C revised to 35 °C;
--- Change the test contents affect the amount of increase for seals, mechanical shock and electromagnetic compatibility requirements;
--- Air circuit test content increases the collection efficiency of the test, the amount of time on the value range by a revised 1h ~ 100h 30min ~ 100h;
--- "Air dose rates" to "air kerma rate." Use this section should be combined with the GB/T 7165.1-2005.
This part is proposed by the China National Nuclear Corporation.
GB/T 7165.4-2008/IEC 60761-4:2002 this part of the National Nuclear Instrument Standardization Technical Committee.
This section is drafted. Shanghai Nuclear Engineering Research and Design Institute.
Drafters of this section. Fu Xi Shi red.
Original standard was first released in October 1989.
GB/T 7165.4-2008/IEC 60761-4:2002 Gaseous effluents (radioactive) activity Continuous monitoring equipment Specific requirements for radioactive iodine monitors. Part 4
1 Scope
GB/T 7165 This section applies to all forms of radioactive iodine for the same time, delay or sequentially measuring device. When the flow of discharge when sampling measurements, attached to the aerosol iodine generally consists of pre-filter is collected, and then analyzed separately in the laboratory, to mention for complete measurement.
Radioactive iodine monitors should have the following features.
--- Measuring gaseous exhaust stream total activity volume activity of iodine and iodine compounds and emissions of radioactive iodine;
--- When the radioactivity concentration or total activity iodine or an iodine compound exceeds a preset threshold, the start alarm signal.
Such devices will be measured in the presence of gaseous effluents of radionuclides other activity, including natural radionuclides. Its He radionuclide screening when measuring low levels of radioactive iodine is very important.
The chimney or ventilation pipe, this section takes into account both the use of activated carbon as iodine sampling medium, but also consider the direct iodine measuring.
The purpose of this section is to set out the provisions of Chapter 4 iodine monitors specific standard requirements, including technical characteristics and general test conditions, and give Examples of possible approaches.
GB/T 7165.1-2005 in the general requirements for such equipment, technical characteristics, test methods, radiation characteristics, electrical characteristics, mechanical Mechanical characteristics, security features and environmental characteristics. Unless otherwise noted, these requirements apply to this section.
2 Normative references
The following documents contain provisions which, through GB/T reference in this 7165 constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 2423.5 Environmental testing for electric and electronic products Part 2. Test methods Test Ea and guidance. Shock (GB/T 2423.5-1995, idt IEC 60068-2-27. 1987) GB/T 7165.1-2005 gaseous effluents (radioactive) activity continuous monitoring equipment - Part 1. General requirements (IEC 60761-1:2002, IDT) GB 9254 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement (GB 9254-1998, idt IEC/CISPR22.
1997)
GB/T 17626 (all parts), electromagnetic compatibility test and measurement technology (idt IEC 61000)
3 Terms and Definitions
GB/T 7165.1-2005 to establish the following terms and definitions apply to this section.
Unless otherwise indicated, the portion used "iodine" refers to compounds and non-radioactive iodine compounds exist in all forms, including Attached iodine in aerosol.
Note. iodine is usually the first aerosol collected on a pre-filter, and then analyzed separately in the laboratory.
GB/T 7165.4-2008/IEC 60761-4:2002
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.5Environmental testing - Part 2: Test methods - Test Ea and guidance: Shock
- GB/T 2423.5-1995Environmental testing - Part 2: Test methods - Test Ea and guidance: Shock
- GB/T 7165.1-2005Equipment for continuous monitoring of radioactivity in gaseous effluents -- Part 1: General requirements
IEC 60068 · IEC 60761 · GB 9254 · GB 9254-1998 · IEC/CISPR22 · GB/T 17626 · IEC 61000
How to Download GB/T 7165.4-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17626.1-2006 — [Replaced by GB/Z 17626.1-2024] Electromagnetic compatibility -- Testing and measurement techniques -- Overview of immunity tests
GB/T 17626.10-2017 — Electromagnetic compatibility -- Testing and measurement techniques -- Damped oscillatory magnetic field immunity test
GB/T 17626.11-2023 — Electromagnetic compatibility - Testing and measurement techniques - Part 11: Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
Secure payment via Stripe
Payments accepted
GB/T 7165.4-2008
$95.00