Valid

GB/T 7165.2-2008Equipment for continuous monitoring of radioactivity in gaseous effluents -- Part 2: Specific requirements for radioactive aerosol monitors including transuranic aerosols (English PDF)

气态排出流(放射性)活度连续监测设备 第2部分:放射性气溶胶(包括超铀气溶胶)监测仪的特殊要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for GB/T 7165.2-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

June 19, 2008

Implementation date

April 1, 2009

Scope

GB/T 7165.2-2008 is the English-translated version of 气态排出流(放射性)活度连续监测设备 第2部分:放射性气溶胶(包括超铀气溶胶)监测仪的特殊要求.

GB/T 7165.2-2008 — GB/T 7165 This section applies to the same time, delay or sequentially to measure the aerosol stream environmental emissions equipment discharge.

Such equipment shall have the following functions. --- Measuring aerosol stream discharge volume activity (Bq/m3) and/or the total aerosol discharge activity (Bq); --- When more than a predetermined aerosol volume activity or predetermined total emission activity, activates the alarm signal.

Such apparatus is used to measure activity within a wide range, including very small amount in a large natural background in the presence of. Natural background of aerosol Gum normally present in the 222Rn and 220Rn daughters.

Monitoring low-level activity, one important issue is to identify the background activity. in order to to provide more and more accurate information, you can filter after sampling to supplement or subsequent laboratory analysis.

The purpose of this section is to provide specific standards, including technical characteristics and general test conditions and gives the aerosol effluent monitors Examples of possible approaches.

GB/T 7165.1-2005 gives the general requirements, technical characteristics, test methods, radiation characteristics, electrical characteristics, mechanical characteristics, safety Characteristics and environmental characteristics. Unless otherwise noted, these requirements apply to this section.

Found what you need?

Document preview — GB/T 7165.2-2008

National Standard of the People's Republic of China

ICS
13.280
Classification
F 84
Replacing
GB/T 7165.2-1988; GB/T 7165.6-1989

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

This part of GB/T 7165 "gaseous effluents (radioactive) activity continuous monitoring equipment" Part 2, the standard includes a lower total Column five parts.

--- GB/T 7165.1 "gaseous effluents (radioactive) activity continuous monitoring equipment - Part 1. General requirements";

--- GB/T 7165.2 "gaseous effluents (radioactivity) Equipment for continuous monitoring activity - Part 2. radioactive aerosols (including transuranic Aerosol) monitors the special requirements ";

--- GB/T 7165.3 "gaseous effluents (radioactive) activity continuous monitoring equipment - Part 3. radioactive noble gas monitors special requirements";

--- GB/T 7165.4 "gaseous effluents (radioactive) activity continuous monitoring equipment - Part 4. radioactive iodine monitors special Special requirements ";

--- GB/T 7165.5 "gaseous effluents (radioactive) activity continuous monitoring equipment - Part 5. Particular requirements for tritium monitors." this section identical with IEC 60761-2:2002 "gaseous effluents (radioactivity) Equipment for continuous monitoring activity Part 2. Radioactive gas Sol (including transuranic aerosols) monitors the special requirements "(in English).

For ease of use, this section of IEC 60761-2:2002 made the following editorial changes.

--- Delete the original preface to the international standards;

--- According to Chinese customs for some formatting has been modified (for example. Note plus behind ".", followed by a series Item Description will be. "" Replaced by ";");

--- Use the decimal symbol instead of the international standard decimal symbol ",". ",";

--- Will be in "2 Normative references" existing national standards and industry standards relevant international standards to our standards (in GB/T 2423.5 instead of IEC 60028-2-27. 1987, with GB/T 7165.1-2005 instead of IEC 60761-2:2002, in order to GB/T 17626 instead of IEC 61000, to EJ/T 1010-1996 instead of IEC 61578:1997, to replace the GB 9254 IEC/CISPR22.1997), by deleting the standard EN481 does not appear in the text 1993;

--- 12.5 Uncertainty has been included in the range, it will be "± 10%" to "10%";

--- Retain only the contents of the current used in the voltage and frequency of the AC power;

--- Delete reference.

This Part replaces GB/T 7165.2-1988 "the second part of the gaseous effluents (radioactive) activity Continuous monitoring equipment. Aerosol row Specific requirements for the monitors "and GB/T 7165.6-1989" gaseous effluents (radioactivity) Equipment for continuously monitoring activity Part VI.

Particular requirements for transuranic aerosol effluent flow monitors. " Appendix A of this section is an informative annex.

Use this section should be combined with the GB/T 7165.1-2005.

This part is proposed by the China National Nuclear Corporation.

This part of the National Nuclear Instrument Standardization Technical Committee.

This section is drafted. Shenzhen Academy of Metrology and Quality Inspection, Fujian Province Science and Technology Institute of measurement.

1 Scope

GB/T 7165 This section applies to the same time, delay or sequentially to measure the aerosol stream environmental emissions equipment discharge.

Such equipment shall have the following functions.

--- Measuring aerosol stream discharge volume activity (Bq/m3) and/or the total aerosol discharge activity (Bq);

--- When more than a predetermined aerosol volume activity or predetermined total emission activity, activates the alarm signal.

Such apparatus is used to measure activity within a wide range, including very small amount in a large natural background in the presence of. Natural background of aerosol Gum normally present in the 222Rn and 220Rn daughters. Monitoring low-level activity, one important issue is to identify the background activity. in order to to provide more and more accurate information, you can filter after sampling to supplement or subsequent laboratory analysis.

The purpose of this section is to provide specific standards, including technical characteristics and general test conditions and gives the aerosol effluent monitors Examples of possible approaches.

GB/T 7165.1-2005 gives the general requirements, technical characteristics, test methods, radiation characteristics, electrical characteristics, mechanical characteristics, safety Characteristics and environmental characteristics. Unless otherwise noted, these requirements apply to this section.

2 Normative references

The following documents contain provisions which, through GB/T reference in this 7165 constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 2423.5 Environmental testing for electric and electronic products Part 2. Test methods Test Ea and guidance. Shock (GB/T 2423.5-1995, idt IEC 60068-2-27. 1987) GB/T 7165.1-2005 gaseous effluents (radioactive) activity continuous monitoring equipment - Part 1. General requirements (IEC 60761-1:2002, IDT) GB 9254 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement (GB 9254-1998, idt IEC/CISPR22.

1997)

GB/T 17626 (all parts), electromagnetic compatibility test and measurement technology (idt IEC 61000) EJ/T 1010-1996 alpha, beta radioactive aerosol monitor calibration and compensation effectiveness of radon progeny test method (eqv IEC 61578:1997)

3 Terms and Definitions

GB/T 7165.1-2005 to establish the following terms and definitions apply to this section.

Solid or liquid particles in air or other gases formed in the suspension.

Units and aerosol particles have the same settling velocity density diameter spherical particles.

GB/T 7165.2-2008/IEC 60761-2:2002

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 7165.2-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 7165.2-2008

$145.00