GB/T 6075.2-2012Mechanical vibration -- Evaluation of machine vibration by measurements on non-rotating parts -- Part 2: Land-based steam turbines and generators in excess of 50MW with normal operating speeds of 1500r/min, 1800r/min, 3000r/min and 3600r/min (English PDF)
Also coversGBT6075.2-2012
Open the GB/T 6075.2-2012 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
November 5, 2012
Implementation date
March 1, 2013
Scope
GB/T 6075.2-2012 (Mechanical vibration -- Evaluation of machine vibration by measurements on non-rotating parts -- Part 2: Land-based steam turbines and generators in excess of 50MW with normal operating speeds of 1500r/min, 1800r/min, 3000r/min and 3600r/min) is available as an English-translated PDF.
GB/T 6075.2-2012 — GB/T 6075 provisions of this part of the site evaluation machine vibration intensity for all main bearing housing or bearing shaft diameter To (ie, transverse) and thrust bearing broadband axial vibration measurements. They include. --- Normal steady-state operating conditions of vibration; --- Transients (including the raising speed or deceleration, plus initial load and load changes) when the other (non-steady-state) conditions during vibration; --- Vibrations occur during normal steady state operation of the change. This section applies to the rated speed 1500r/min, 1800r/min, 3000r/min or 3600r/min, the output power is greater than 50MW of turbines and generators installed on land, also applies to the direct coupling of the gas turbine and steam turbine (or) a generator (such as the United Combined cycle applications). Under these circumstances, the guidelines in this section apply only to the steam turbine and generator (including synchronizing clutch). ISO 7919-4 Suitable for a gas turbine and ISO 10816-4 Evaluation of vibration. These evaluation criteria in this section do not apply to the excitation of vibration in the generator stator core and the housing 2 octave electromagnetic. Values \u200b\u200bspecified in this section is not intended as the sole basis for evaluation of vibration intensity. For large turbines and generators, often used Vibration of rotating shaft evaluated. These vibration measurement requirements, see GB/T 11348.1 and GB/T 11348.2.
Document preview — GB/T 6075.2-2012
National Standard of the People's Republic of China
- ICS
- 17.160
- Classification
- J 04
- Replacing
- GB/T 6075.2-2007
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Measurement Methods
Foreword
GB/T 6075 "Mechanical vibration Evaluation of machine vibration measurements on non-rotating member" is divided into seven sections.
--- Part 1. General;
--- Part 2. more than 50MW of power, rated speed 1500r/min, 1800r/min, 3000r/min, 3600r/min Lu
Mounted turbine and generator;
--- Part 3. rated power above 15kW and nominal speeds range between 120r/min to 15000r/min in the Field Test
The amount of industrial machinery;
--- Part 4. Gas turbine sets with a sliding bearing;
--- Part 5. hydroelectric and pumping plants;
--- Part 6. power of more than 100kW reciprocating machine;
--- Part 7. The rotary power pumps for industrial applications, including measurements on rotating shafts.
This part of GB/T 26075 Part of.
This section drafted in accordance with the rules of GB/T 1.1-2009 and GB/T 20000.2-2009 given.
This Part replaces GB/T 6075.2-2007 "Measurement and Evaluation of the machine on the non-rotating member of the mechanical vibration - Part 2.
50MW or more, rated speed 1500r/min, 1800r/min, 3000r/min, 3600r/min land installed steam turbine, generator
machine". This section compared with the GB/T 6075.2-2007, the main modifications are as follows.
--- Modify the standard name from the original "Measurement and evaluation of the machine on a non-rotating member of the mechanical vibration - Part 2. 50MW
Above the rated speed 1500r/min, 1800r/min, 3000r/min, 3600r/min land installed steam turbine, generator
Machine "to" mechanical vibration measurement and evaluation of the machine vibration on non-rotating parts - Part 2. Power 50MW or more, the amount of
Set speed 1500r/min, 1800r/min, 3000r/min, 3600r/min steam turbines and generators installed on land ";
--- Increase on a constant vibration velocity criteria at low speed warning (see Appendix C);
--- Modify the requirement to use a different zone boundary value example (see 4.2.2.4);
--- When the new machine does not have to establish an effective baseline data, recommended its alarm steady state operation under the rated operating speed should not exceed area
Boundary B/C (see 4.2.3.2);
--- Increasing the stop value is set in relation to a second alarm (see 4.2.3.3);
--- Increased vibration values \u200b\u200ba transient operating conditions (transient operation) during the "Shutdown amplification factor" concept, in steady conditions
Prior to the establishment, it will automatically enhance the "alarm" and "Stop value" (see 4.2.4). About "Stop amplification factor" is used,
4.2.4.4 to do a more detailed description;
--- Revising the acceleration, vibration speed and magnitude of a deceleration period. And to delete the previous version in Figure 2 (see 4.2.4.3).
--- Modify the previous edition of "vibration amplitude" translation many will read "vibration magnitude."
2009 "Mechanical vibration measurement and evaluation of the machine vibration on non-rotating parts. This section uses the translation method using equivalent ISO 10816-2
Part 2. Power 50MW or more, rated speed 1500r/min, 1800r/min, 3000r/min, 3600r/min land installation
Turbine and generator. "
Consistency correspondence between this part of international documents and normative references of our files are as follows.
--- GB/T 11348.2-2012 Mechanical vibration machine vibration measurement and evaluation of the rotating shaft Part 2. Power greater than
50MW, rated operating speed 1500r/min, 1800r/min, 3000r/min, 3600r/min land turbine installation
And generator (ISO 7919-2.1995, MOD).
This part of the National mechanical vibration, shock and condition monitoring Standardization Technical Committee (SAC/TC53) and focal points.
This section is drafted. Zhengzhou Machinery Research Institute, Xi'an Thermal Power Research Institute Co., Ltd., Shanghai Power Equipment Research Institute,
Harbin Institute of Electronics, Henan Electric Power Research Institute, Dongfang Electric Group, Dongfang Electrical Machinery Co., Ltd., Shanghai power plant equipment company Shanghai
Generator plant.
Introduction
GB/T 6075.1 is GB/T 6075 basic technical document, which sets out a non-rotating parts vibration measurement and evaluation of different types of machines
General requirements for moving. GB/T 6075 gives this part of the vibration in a large turbine and generator bearing housing or supporting base measurement
Specified intensity evaluation. Characterization of the vibrational state can be measured quite well in these positions. Evaluation on the basis of past experience on the proposed
Criteria, such as evaluation of machine vibration state guidelines.
In the steady state running conditions, the provisions of the two criteria evaluation of machine vibration. The first criterion to consider is the measured vibration magnitude; s
Changes in these two criteria are vibration magnitude. In addition, transient operating conditions provides different criteria. However, the vibration on non-rotating member
Move is not the sole basis for evaluation of machine vibration intensity. For large turbines and generators, it is usually based on the rotating shaft vibration measurement and evaluation
Moving; rotating shaft vibration measurement and evaluation requirements see GB/T 11348.1 and GB/T 11348.2.
Evaluation method proposed in this section is based on broadband measurements. However, due to the use of technological progress, or narrow-band spectrum analysis measurements increasingly
The more common, especially for vibration evaluation, condition monitoring and diagnostics. Guidelines for the evaluation of these measurements is beyond the scope of this section, it
They machine vibration condition monitoring in the ISO 13373 standard in detail (all parts) in.
Mechanical vibration measurement and evaluation unit in the non-rotating member
The vibration - Part 2. Power 50MW or more,
Rated speed 1500r/min, 1800r/min,
3000r/min, 3600r/min land installation
Turbine and generator
1 Scope
GB/T 6075 provisions of this part of the site evaluation machine vibration intensity for all main bearing housing or bearing shaft diameter
To (ie, transverse) and thrust bearing broadband axial vibration measurements. They include.
--- Normal steady-state operating conditions of vibration;
--- Transients (including the raising speed or deceleration, plus initial load and load changes) when the other (non-steady-state) conditions during vibration;
--- Vibrations occur during normal steady state operation of the change.
This section applies to the rated speed 1500r/min, 1800r/min, 3000r/min or 3600r/min, the output power is greater than
50MW of turbines and generators installed on land, also applies to the direct coupling of the gas turbine and steam turbine (or) a generator (such as the United
Combined cycle applications). Under these circumstances, the guidelines in this section apply only to the steam turbine and generator (including synchronizing clutch). ISO 7919-4
Suitable for a gas turbine and ISO 10816-4 Evaluation of vibration.
These evaluation criteria in this section do not apply to the excitation of vibration in the generator stator core and the housing 2 octave electromagnetic.
Values \u200b\u200bspecified in this section is not intended as the sole basis for evaluation of vibration intensity. For large turbines and generators, often used
Vibration of rotating shaft evaluated. These vibration measurement requirements, see GB/T 11348.1 and GB/T 11348.2.
2 Normative references
The following documents for the application of this section is essential. For dated references, only the edition date of this Part apply to
Minute. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6075.1-2012 mechanical vibration measurement and evaluation of machine vibration on non-rotating parts - Part 1. General
(ISO 10816-1.1995, IDT)
ISO 7919-2 Mechanical vibration measurement and evaluation of the machine on the rotating shaft vibration - Part 2. power greater than 50MW, rated
Speed \u200b\u200b1500r/min, 1800r/min, 3000r/min, 3600r/min land installed turbine and generator (Mechanical
vibration-Evaluationofmachinevibrationbymeasurementsonrotatingshafts-Part 2. Land-based
steamturbinesandgeneratorsinexcessof50MW withnormaloperatingspeedsof1500r/min,
1800r/min, 3000r/minand3600r/min)
3 Measurement Methods
Measurement methods and instrumentation used shall comply with GB/T 6075.1 and the general requirements described below.
For monitoring, measurement systems should be able to measure the frequency range from 10Hz to 500Hz at least a broadband vibration. However, if the instrument is also used
The diagnosis may require wider frequency range of spectral analysis, and (or). For example corresponding to the generator rotor and (or) first critical turn low-pressure rotor
Speed \u200b\u200bis lower than the frequency of 10Hz when the lower limit of the linear range of the measurement system should be reduced accordingly. On special occasions, a significant low frequency vibration
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 6075.1-2012 · ISO 10816 · ISO 7919
How to Buy GB/T 6075.2-2012
- 1Add to cart. Click the "Buy GB/T 6075.2-2012" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12005.2-2026 — Polyacrylamide - Part 2: Determination of properties
GB/T 47068-2026 — Technical requirements for the equipment of construction and demolition waste sorting systems
GB/T 47096-2026 — Green product assessment - Cement
Secure payment via Stripe
Payments accepted
GB/T 6075.2-2012
$550.00