Valid

GB/T 5964-2008Coaxial cable connectors used in nuclear instrumentation (English PDF)

核仪器用同轴电缆连接器

Preview PDF

This is a limited preview

Buy now to download the full PDF (6 pages)

Need quotation for your management?

Get a formal quotation for GB/T 5964-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

July 18, 2008

Implementation date

April 1, 2009

Scope

GB/T 5964-2008 is the English-translated version of 核仪器用同轴电缆连接器.

GB/T 5964-2008 — This standard specifies the high-voltage coaxial connector mating portion of the structure and size of the two types and the main electrical properties.

This standard applies to high-voltage coaxial connectors and nuclear electronic instrument connected. According to the structure and size and technical requirements of this standard manufactured products with similar foreign products in the mechanical and electrical properties can be achieved complete exchange.

About signal transmission coaxial connectors, see Appendix A recommended three signal connector.

Found what you need?

Document preview — GB/T 5964-2008

National Standard of the People's Republic of China

ICS
27.120
Classification
F 81
Replacing
GB/T 5964-1986

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Types and structure size

Foreword

This corresponds to the standard IEC 60498. 1975 "Nuclear instrumentation with high pressure coaxial connectors" and IEC 60313:2002 "Nuclear Laboratory instruments for Coaxial cable connector ", and IEC 60498. 1975 and IEC 60313:2002 non-equivalent.

This standard replaces GB/T 5964-1986 "nuclear instrumentation with high pressure coaxial connectors." this standard and GB/T 5964-1986 The main differences are as follows.

--- Standard name changed to "coax connectors used in nuclear instrumentation";

--- Increase IEC 60729 and other normative references;

--- Increase the "Terms and Definitions", such as "peak voltage", "safe high-voltage connector (SHV)" and other terms;

--- Increase in Appendix A "signal transmitted by a coaxial cable connector", whose contents are IEC 60313 recommended three coaxial signal transmission Cable connectors.

Appendix A of this standard is a normative appendix.

The standard proposed by China National Nuclear Corporation.

This standard by the National Standardization Technical Committee on nuclear instrumentation.

This standard was drafted. nuclear (Beijing) Nuclear Instrument Factory, Institute of Nuclear Industry Standardization.

1 Scope

This standard specifies the high-voltage coaxial connector mating portion of the structure and size of the two types and the main electrical properties.

This standard applies to high-voltage coaxial connectors and nuclear electronic instrument connected.

According to the structure and size and technical requirements of this standard manufactured products with similar foreign products in the mechanical and electrical properties can be achieved complete exchange. About signal transmission coaxial connectors, see Appendix A recommended three signal connector.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 14865 SMB RF coaxial connectors (GB/T 14865-1993, idt IEC 60169-10. 1983) IEC 60169-8. 1978 RF connectors - Part 8. a bayonet locking, inside the insulator diameter of 6.5 mm (0.256 Inch) R. F. The coaxial cable connector characteristic impedance of 50 ohms (BNC type) (including Amendment 1.1996 and Amendment 2.1997) IEC 60729 CAMAC chassis multiple controllers

3 Terms and Definitions

The following terms and definitions apply to this standard.

Relative to baseline (OV) positive or negative voltage to the maximum value.

5kV voltage reaches the high-voltage connector.

Coaxial cable connection screw locking buckle ultra-miniature devices, also known as SMA connectors.

Connect coaxial cable ultra-miniature push the locking device, also known as SMB connectors.

4 Types and structure size

4.1 I-type high voltage coaxial connectors 4.1.1 plug structure and size, as shown in Table 1 and 1.

4.1.2 socket structure and dimensions, as shown in Table 2 and 2.

Note. I type high voltage coaxial connector is secure high-voltage connector, the peak voltage up to 5kV.

4.2 II type high voltage coaxial connectors 4.2.1 plug structure and dimensions shown in Figure 3 and Table 3.

4.2.2 socket structure and dimensions, as shown in Table 4 and 4.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 14865 · GB/T 14865-1993 · IEC 60169 · IEC 60729

How to Download GB/T 5964-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe