GB/T 5275.4-2014Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 4: Continuous syringe injection method (English PDF)
气体分析 动态体积法制备校准用混合气体 第4部分:连续注射法
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for GB/T 5275.4-2014 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
July 8, 2014
Implementation date
December 1, 2014
Scope
GB/T 5275.4-2014 is the English-translated version of 气体分析 动态体积法制备校准用混合气体 第4部分:连续注射法.
GB/T 5275.4-2014 — GB/T 5275 provisions of this section from a pure gas or gas mixture through a syringe to the other balance calibration gas is continuously injected components, from Continuously prepared containing two or more components of the gas mixture with the calibration methods.
Use premixed gas instead of pure gas (see Appendix A) can be prepared in a mixed gas volume fraction low. Determine the volume fraction of the volume flow, by a single flow of gas is calculated, it may also be an appropriate method of independent measurements given in ISO 6145-1.
Advantage of continuous injection law can be prepared continuously large number of mixed gas, and as long as the appropriate number of syringes or single syringe Known multi-component gas mixture containing the gas can be as prepared as easily as binary mixtures prepared multi-component gas mixture.
The method may further by a few steps and easily increase calibration components in a mixed gas volume fraction. Therefore, it can be used to evaluate a gas analyzer Some other features, such as the limit of detection, blind and accuracy.
Binary mixed gas prepared by the method (coverage factor k = 2) relative expanded Uncertainty of 5%, the scope of 10-5 to 10-2 (volume fraction).
Found what you need?
Document preview — GB/T 5275.4-2014
National Standard of the People's Republic of China
- ICS
- 71.040.40
- Classification
- G 86
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
Foreword
GB/T 5275 "gas analysis dynamic volume Preparation of calibration gas mixtures" is divided into the following sections.
--- Part 1. calibration method;
--- Part 2. positive displacement pump;
--- Part 4. continuous injection;
--- Part 5. Capillary calibration devices;
--- Part 6. Critical orifices;
--- Part 7. Thermal mass flow controller;
--- Part 8. Diffusion method;
--- Part 9. Saturation method;
--- Part 10. Permeation;
--- Part 11. Electrochemical method occurs.
This section GB/T 45275 Part of.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with ISO 6145-4:2004 "gas analysis dynamic volume Preparation of calibration gas mixtures 4th Part I. Continuous injection method. " Consistency correspondence between this part of international documents and normative references of our files are as follows.
--- GB/T 10628-2008 gas analysis calibration gas mixture composition measurements and comparison test (ISO 6143:2001, IDT);
--- GB/T 5275.1-2014 gas analysis equipment dynamic volume Method of calibration gas mixtures - Part 1. calibration method (ISO 6145-1:2003, IDT).
This part is proposed by the China Petroleum and Chemical Industry Association.
This part of the National Gas Standardization Technical Committee (SAC/TC206) centralized.
This section drafted by. China Institute of Metrology, Southwest Chemical Industry Research and Design Institute Co., Ltd., Beijing helium gas industry has divided the North Cape Limited, the Ministry of Environmental Protection Institute of the standard sample.
1 Scope
GB/T 5275 provisions of this section from a pure gas or gas mixture through a syringe to the other balance calibration gas is continuously injected components, from Continuously prepared containing two or more components of the gas mixture with the calibration methods.
Use premixed gas instead of pure gas (see Appendix A) can be prepared in a mixed gas volume fraction low. Determine the volume fraction of the volume flow, by a single flow of gas is calculated, it may also be an appropriate method of independent measurements given in ISO 6145-1.
Advantage of continuous injection law can be prepared continuously large number of mixed gas, and as long as the appropriate number of syringes or single syringe Known multi-component gas mixture containing the gas can be as prepared as easily as binary mixtures prepared multi-component gas mixture. The method may further by a few steps and easily increase calibration components in a mixed gas volume fraction. Therefore, it can be used to evaluate a gas analyzer Some other features, such as the limit of detection, blind and accuracy. Binary mixed gas prepared by the method (coverage factor k = 2) relative expanded Uncertainty of 5%, the scope of 10-5 to 10-2 (volume fraction).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
ISO 6143 Gas analysis calibration gas mixture composition measurements and check Comparative Law (Gasanalysis-Comparison methodsfordeterminingandcheckingthecompositionofcalibrationgasmixtures) ISO 6145-1 Gas analysis dynamic volume Preparation of calibration gas mixtures - Part 1. calibration method (Gasanalysis-Preparationofcalibrationgasmixturesusingdynamicvolumetricmethods-Part 1. Methodsofcali-bration) Principle 3 Component calibration gas or liquid phase by syringe into the capillaries and then into the gas stream balance, the capillary can be a needle injection device Vials, syringes, pistons driven by a suitable variable speed motor.
A component in the gas mixed with the balance gas volume fraction phiA B by the formula (1) is given by.
phiA = qA/(qA qB) (1) where.
qA --- calibration component A volume flow;
Gas volume flow qB --- balance of B.
If the calibration component is injected as a liquid, the gas flow rate after the volatile by the formula (2) is given by.
qA = (qA, l × rhoA, l)/rhoA, g (2) where.
qA, l --- injection volume flow rate of liquid, which is the same unit of measure qA;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 6143 · ISO 6145
How to Download GB/T 5275.4-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 5275.1-2024 — Gas analysis - Preparation of calibration gas mixtures using dynamic methods - Part 1: General aspects
GB/T 5275.10-2009 — Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 10: Permeation method
GB/T 5275.11-2014 — Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 11: Electrochemical generation
Secure payment via Stripe
Payments accepted
GB/T 5275.4-2014
$235.00