Valid

GB/T 5195.16-2017Fluorspar—Determination of silicon, aluminum, iron, potassium, magnesium and titanium content—Inductively coupled plasma atomic emission spectrometry (English PDF)

萤石 硅、铝、铁、钾、镁和钛含量的测定 电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 5195.16-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

September 7, 2017

Implementation date

June 1, 2018

Scope

GB/T 5195.16-2017 is the English-translated version of 萤石 硅、铝、铁、钾、镁和钛含量的测定 电感耦合等离子体原子发射光谱法.

GB/T 5195.16-2017 is Part 16 of GB/T 5195, which the foreword divides into sixteen parts, and it prescribes the determination of the silicon, aluminium, iron, potassium, magnesium and titanium contents of fluorspar by inductively coupled plasma atomic emission spectrometry.

Clause 1 confines the part to fluorspar and fixes the determination range of each element as a mass fraction in Table 1: silicon 0.20 % to 18.50 %, aluminium and iron 0.020 % to 2.50 %, potassium 0.020 % to 2.00 %, and magnesium and titanium 0.010 % to 2.00 %.

Under the principle in clause 3 the sample is fused with sodium hydroxide in a zirconium crucible, leached with boric acid solution and acidified with nitric acid, after which the solution is atomized through a high-salt nebulizer into the inductively coupled plasma emission spectrometer, the net line intensity of each analytical line is measured and the element contents are calculated from an established calibration curve.

A warning placed ahead of clause 1 restricts the part to personnel with formal laboratory experience, states that it does not indicate every possible safety issue, and leaves the user responsible for appropriate safety and health measures and for compliance with the relevant national laws and regulations.

Clause 2 cites GB/T 6379.1 and GB/T 6379.2 on the accuracy and precision of measurement methods, GB/T 6682 on water for analytical laboratory use, GB/T 8170 on rounding and the expression and judgement of limiting values, and GB/T 22564 on fluorspar sampling and sample preparation.

The contents run from the Foreword and clause 1 Scope through clause 2 Normative references, clause 3 Principle and clause 4 Reagents, which admits only analytical grade reagents and grade two water conforming to GB/T 6682.

The part was proposed by the China Iron and Steel Association and is administered by the national technical committee on steel standardization (SAC/TC 183), with the Ningbo entry-exit inspection and quarantine authority, China Inspection and Certification Group Ningbo Co., Ltd. and the Metallurgical Industry Information Standards Institute among the drafting organizations. It was issued on September 7, 2017 and has applied since June 1, 2018.

Found what you need?

Document preview — GB/T 5195.16-2017

National Standard of the People's Republic of China

ICS
73.080
Classification
D 52

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Principle
  • 4 Reagent

Foreword

GB/T 5195 is divided into 16 parts.

--- Part 1. Determination of fluorite calcium fluoride content EDTA titration and distillation - potentiometric titration;

--- Part 2. Determination of fluorite carbonate content;

--- Part 3. Fluorite 105 °C quality determination of the weight method;

--- Part 4. Determination of fluorite sulfide content iodometric method;

--- Part 5. Determination of total sulfur content of fluorite tube furnace combustion - potassium iodate titration;

--- Part 6. Determination of fluorite content of phosphorus spectrophotometry;

--- Part 7. Determination of zinc content of fluorite; atomic absorption spectrometry;

--- Part 8. Determination of fluorite silica content;

--- Part 9. Determination of weight loss of fluorite burning weight method;

--- Part 10. Determination of iron content of fluorite phenanthroline spectrophotometry;

--- Part 11. Determination of fluorspar content; Periodate spectrophotometry;

--- Part 12. Determination of arsenic content of fluorite; atomic fluorescence spectrometry;

--- Part 13. Determination of aluminum content of fluorite EDTA titration method;

--- Part 14. Determination of magnesium content of fluorite flame atomic absorption spectrometry;

--- Part 15. Determination of calcium, aluminum, silicon, phosphorus, sulfur, potassium, iron, barium and lead contents of fluorite; wavelength dispersive X - ray fluorescence spectrometry;

--- Part 16. Determination of fluorite silicon, aluminum, iron, potassium, magnesium and titanium content Inductively coupled plasma atomic emission spectrometry. This section GB/T 5195 Part 16: This section drafted in accordance with GB/T 1.1-2009 given rules.

1 Scope

This section GB/T 5195 specifies the use of inductively coupled plasma atomic emission spectrometry Determination of silicon, aluminum, iron, potassium, magnesium and titanium containing The amount of method.

This section applies to the determination of fluorite in silicon, aluminum, iron, potassium, magnesium and titanium. Determination of the content of elements in Table 1.

Table 1 Determination of elemental content range (mass fraction) /%:

Si 0.20 ~ 18.50

Al 0.020 ~ 2.50

Fe 0.020 ~ 2.50

K 0.020 ~ 2.00

Mg 0.010 ~ 2.00

Ti 0.010 ~ 2.00

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 6379.1 accuracy and accuracy of measurement methods (accuracy and precision) Part 1: General and definitions

GB/T 6379.2 accuracy of measurement methods and results (accuracy and precision) Part 2: Determination of standard measurement methods repeated The basic method of sexuality and reproducibility

GB/T 6682 analytical laboratory water specifications and test methods

GB/T 8170 rounded repair rules and limit values of the representation and judgment

GB/T 22564 fluorite sampling and sample preparation

3 Principle

The sample was melted with sodium hydroxide in a zirconium crucible, leached with boric acid solution, and acidified with nitric acid. The use of high salt atomizer, the sample solution atomized After the introduction of inductively coupled plasma emission spectrometer, determination of the net light intensity of each element analysis line, according to the established calibration curve, calculated The content of each element in the sample.

4 Reagent

Unless otherwise specified, only reagents identified as analytical grade and secondary water conforming to GB/T 6682 are used in the analysis.

4.1 Sodium hydroxide.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 5195.16-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 5195.16-2017

$145.00