GB/T 5195.13-2017Fluorspar - Determination of aluminium content - EDTA titration method (English PDF)
萤石 铝含量的测定 EDTA滴定法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 5195.13-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 7, 2017
Implementation date
June 1, 2018
Scope
GB/T 5195.13-2017 is the English-translated version of 萤石 铝含量的测定 EDTA滴定法.
GB/T 5195.13-2017 is the Chinese standard "Fluorspar - Determination of aluminium content - EDTA titration method". Its scope clause reads: This section GB/T 5195 specifies the method of EDTA determination of aluminum content with ethylenediaminetetraacetic acid (EDTA) titration method.
This section applies to the determination of aluminum content in fluorite. Measurement range (mass fraction) .0.20% ~ 3.00%. Its clauses include principle; reagents and materials.
Found what you need?
Document preview — GB/T 5195.13-2017
National Standard of the People's Republic of China
- ICS
- 73.080
- Classification
- D 52
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 principle
- 4 Reagents and materials
1 Scope
This section GB/T 5195 specifies the method of EDTA determination of aluminum content with ethylenediaminetetraacetic acid (EDTA) titration method.
This section applies to the determination of aluminum content in fluorite. Measurement range (mass fraction) .0.20% ~ 3.00%.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 6682 analytical laboratory water specifications and test methods
GB/T 8170 rounded repair rules and limit values of the representation and judgment
GB/T 14506.8 Methods for chemical analysis of silicate rocks Part 8. Determination of titanium dioxide
GB/T 22564 fluorite sampling and sample preparation
3 principle
The sample was hydrofluoric acid - sulfuric acid - perchloric acid decomposition, evaporated to dry with potassium pyrosulfate melt. Hydrochloric acid solution made hydrochloric acid solution, add an excess
EDTA and iron, aluminum, titanium plasma coordination, adjust the pH of about 4.5 to nitrosyl R salt as an indicator, the standard solution of copper sulfate titration
The amount of EDTA, potassium fluoride to replace with aluminum, titanium coordination EDTA, titration with copper sulfate standard solution, measured aluminum, titanium, minus the amount of titanium
Amount, that is, the content of aluminum.
4 Reagents and materials
Unless otherwise stated, only the reagents identified as analytical grade are used in the analysis. The water used shall meet the requirements of the secondary water of GB/T 6682
Claim.
Hydrofluoric acid, rho = 1.19 g/mL.
4.2
perchloric acid, rho = 1.69g/mL.
4.3
Glacial acetic acid, rho = 1.05 g/mL.
4.4
pyrosulfate potassium.
4.5
sulfuric acid solution, 1 1.
4.6
ammonia solution, 1 1.
4.7
hydrochloric acid solution, 1 9.
4.8
potassium fluoride solution, 100g/L.
Weigh 20g potassium fluoride, dissolved in.200mL water.
4.9
Acetic acid-ammonium acetate buffer solution, pH = 4.5.
Weigh 71g ammonium acetate dissolved in 500mL water, add 58.5mL glacial acetic acid (4.3), diluted with water to 1000mL, shake.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 5195.13-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 5195.14-2017 — Fluorspar - Determination of magnesium content - Flame atomic absorption spectrometry
GB/T 5195.12-2016 — Fluorite - Determination of arsenic content - Atomic fluorescence spectrometry
GB/T 5195.15-2017 — Fluorspar—Determination of calcium,aluminum,silicon,phosphorus,sulfur,potassium,iron,barium and lead content—Wavelength dispersive X-ray fluorescence spectrometric method
GB/T 5195.13-2017
$145.00