Valid

GB/T 47980-2026Technical requirements for real-time monitoring of energy consumption in pumping systems (English PDF)

泵系统能耗实时监控技术要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (24 pages)

Need quotation for your management?

Get a formal quotation for GB/T 47980-2026 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 30, 2026

Implementation date

February 1, 2027

Scope

GB/T 47980-2026 is the English-translated version of 泵系统能耗实时监控技术要求.

GB/T 47980-2026 is the Chinese standard "Technical requirements for real-time monitoring of energy consumption in pumping systems".

Its scope clause reads: This document establishes the general principles and monitoring scope for real-time monitoring of pump system energy consumption, and specifies the technical requirements, functional verification, and operation. maintain.

This document applies to rotary power pumps (centrifugal pumps, mixed-flow pumps, and axial-flow pumps, etc.) and their pump units (driven by electric motors, steam turbines, or internal combustion engines, etc.).

Real-time monitoring of energy consumption during operation of the pump system (motor), and other types of pump systems should follow the same procedure. Its clauses include terms and definitions; general principles.

Found what you need?

Document preview — GB/T 47980-2026

National Standard of the People's Republic of China

ICS
27.010
Classification
F 01

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1.Scope1
  • 2 Normative references1
  • 3.Terms and Definitions1
  • 4 General Principles1
  • 5.Monitoring range2
  • 6.Technical Requirements3
  • 7 Functional verification and operation and maintenance9
  • Appendix A (Normative) Formulas for Calculating Energy Consumption Performance Indicators of Pump Systems11
  • Appendix C (Informative) Example of Pump System Energy Consumption Early Warning Project16
  • Appendix D (Informative) Example of Building a Real-time Energy Consumption Monitoring Platform for Pump Systems18
  • References19

1 Scope

This document establishes the general principles and monitoring scope for real-time monitoring of pump system energy consumption, and specifies the technical requirements, functional verification, and operation.

maintain.

This document applies to rotary power pumps (centrifugal pumps, mixed-flow pumps, and axial-flow pumps, etc.) and their pump units (driven by electric motors, steam turbines, or internal combustion engines, etc.).

Real-time monitoring of energy consumption during operation of the pump system (motor), and other types of pump systems should follow the same procedure.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are listed below.

For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.

This document.

GB/T 3216 Acceptance Tests of Hydraulic Performance of Rotary Power Pumps - Levels 1, 2 and 3

GB/T 13469 Economic Operation of Centrifugal Pumps, Mixed-Flow Pumps and Axial-Flow Pump Systems

GB/T 16666 Energy-saving monitoring of pump-type liquid transfer systems

GB 18613 Minimum Energy Efficiency Values and Energy Efficiency Grades for Electric Motors

GB 19762 Energy Efficiency Limits and Energy Efficiency Grades for Centrifugal Pumps

GB/T 22239 Information Security Technology - Basic Requirements for Network Security Level Protection

GB 32030 Submersible Pumps - Energy Efficiency Limits and Energy Efficiency Grades

GB/T 36323 Information Security Technology - Basic Requirements for Security Management of Industrial Control Systems

GB/T 38674 Information Security Technology - Guidelines for Secure Programming of Application Software

3 Terms and Definitions

3.1 pumping system

An operating system consisting of one or more pump units and their inlet and outlet pipelines, valves, control devices, etc., with defined working performance.

3.2 Real-time monitoring of energy consumption

The system automatically processes, stores, transmits, and calculates the collected data to achieve real-time monitoring of the pump system's energy consumption status parameters and performance indicators.

Measurement, analysis and early warning, evaluation and optimization, and remote control, etc.

4 General Principles

4.1 Safety and Stability

It can operate continuously, safely, and stably in real time without affecting the integrity and stability of existing equipment and systems, and provides information and network security protection.

The measures are comprehensive.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.

How to Download GB/T 47980-2026

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
24 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 47980-2026