GB/T 47547-2026 is the English-translated version of 直埋保温管道安全运行光纤监测系统技术条件.

GB/T 47547-2026 is the Chinese national standard covering the fibre laid inside the insulation of a buried district heating pipe - it senses temperature along the whole length, which is how a leak is found metres from where it started rather than by digging up a street. First edition, in force since 1 November 2026. It was issued on 30 April 2026 and takes effect on 1 November 2026, as a first edition. The document is under the responsibility of the Ministry of Housing and Urban-Rural Development. This page is published from the official record of the 2026 edition; the clause text of a standard this recent is not yet in circulation, and the figures, limits and tables it contains are those of the document itself, delivered in full with the English translation.

Document preview — GB/T 47547-2026

National Standard of the People's Republic of China

ICS
91.140.10
Classification
P 46

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 6 System Performance
  • 6.1 Temperature Measurement System
  • 7 Layout and Installation
  • 7.1 Arrangement
  • 7.1.1 Optical Cable
  • 7.1.2 Server Rack
  • 7.1.3 Monitoring Platform
  • 7.2 Installation and Laying
  • 7.2.1 Fiber Optic Cable Laying
  • 7.2.2 Server rack and power supply
  • 8 System Testing
  • 8.2 Temperature positioning error test
  • 8.2.1 Test Method
  • 8.3 Temperature Measurement Error Test
  • 8.3.1 Test Method
  • 8.4 Vibration Alarm Test
  • 8.4.1 Test Method
  • 8.5 Monitoring Platform Testing
  • 8.5.1 Display Test
  • 8.5.2 Alarm Test
  • 8.5.3 Data Storage and Retrieval

6.1 Temperature Measurement System

6.1.1 The single-channel temperature measurement time should not exceed 1 minute.

6.1.2 The temperature measurement error should not exceed 3°C.

6.1.3 The temperature measurement positioning error should not exceed 1m.

6.2 Vibration Measurement System The location error of vibration anomalies should not exceed 20m.

7.1.1 Optical Cable

7.1.1.1 Optical cables within the same monitoring channel should be of the same structure and from the same batch.

7.1.1.2 The temperature measurement system and the vibration measurement system should share a single optical cable.

7.1.1.3 The design of the monitoring channel should be determined based on the length of the monitored pipeline and the maximum monitoring distance of the temperature/vibration measuring host.

7.1.1.4 Inspection and testing points should be arranged on the monitoring system, and the maximum pipeline length between two adjacent inspection and testing points should not exceed 5 km. Pilot projects should be set up inside heat exchange stations or thermal well chambers. If there are no thermal well chambers, manhole wells should be set up.

7.1.1.5 The following arrangements can be selected for the cross-sectional layout of optical cables.

a) When two hot water pipes each use one fiber optic cable, it can be installed on the inner or outer side of the lower part of the pipes. The fiber optic cable can be laid in the soil, but... It should not be obstructed by hot water pipes. See Figure 2 for a schematic diagram of the dual optical fiber cable arrangement for hot water pipes.

7.1.2 Server Rack

7.1.2.1 The cabinet can be installed in the control room of the heat exchange primary station, relay pump station, pressure-reducing heat exchange station, and heating station, etc.

7.1.2.2 When the server rack is installed indoors, it shall meet the following requirements.

a) The clearance between the heating pipe and the heating pipe shall not be less than 300mm, and the pipe shall not be installed above the heat dissipation equipment;

b) The net distance from water supply and drainage pipes shall not be less than.200mm;

c) The net distance between the gas pipeline and the gas meter shall not be less than 300mm.

7.1.2.3 When the server rack is installed outdoors, the clear distance between the bottom of the rack and the ground should be greater than 300mm, and there should be no obstructions or climbing obstacles within 1.5m of its perimeter. vegetation.

7.1.3 Monitoring Platform

7.1.3.1 The monitoring platform server can be set up on a cloud server or a server in a self-owned data center.

7.1.3.2 The monitoring platform display interface and the client for the audible and visual alarms should be located in the heating monitoring center and integrated with other heating management platforms. show.

7.2.1 Fiber Optic Cable Laying

7.2.1.1 The bending radius of the optical cable shall not be less than 25 times the outer diameter of the optical cable.

7.2.1.2 Optical cables should be fixed during installation, and the fixing interval should not exceed 3m.

7.2.1.3 The rules for bundling optical cables with conduits are as follows:

a) The sag of the optical cable between two adjacent fixed points should not exceed 50mm, and at least one fixed point should be installed every 12m of optical cable. Fixing points secured with circumferential cable ties;

b) The binding spacing at elbows and bends should not exceed 2m;

c) The performance of the circumferential binding material should comply with the provisions of QB/T 4010, and PET polyester strapping is recommended.

7.2.1.4 Optical cable junction boxes should be located inside heating wells or manholes. Each optical cable outside the junction box should have a pre-existing length and should not... It should be less than 5m.

7.2.1.5 The optical cable reserved in the well chamber should be coiled and placed on the optical cable slack rack.

7.2.1.6 The requirements for fiber optic cable entry manholes are as follows:

a) Flexible hoses should be used for protection when fiber optic cables are introduced into manholes;

b) The two ends of the optical cable that need to be connected should overlap and cross along the axial direction of the pipe before being led into the manhole.

7.2.1.7 The requirements for optical cable connections are as follows:

a) A 1.6m length of optical fiber should be reserved inside the fiber optic splice closure. The radius of curvature of the remaining optical fiber coil should not be less than 30mm. Fiber optic splicing and encapsulation are required. After completion, it is coiled inside the junction box and securely fixed.

b) Each optical fiber should be permanently labeled with a fiber number;

7.2.2 Server rack and power supply

7.2.2.1 The rack installation method can be either base-mounted or suspended, and should meet the following requirements.

a) When using a base-mounted design, the concrete foundation should be pre-constructed according to the dimensions of the temperature/vibration measurement main unit cabinet and the pre-drilled holes at the bottom. The verticality deviation of the rack installation shall not exceed 2% of the height of the temperature/vibration measurement main rack;

b) When using a suspended type, expansion bolt holes should be pre-drilled at the rear of the temperature/vibration measurement main cabinet;

c) After the temperature/vibration measurement main unit cabinet is fixed in place, the optical cable is fused and connected to the temperature/vibration measurement main unit.

7.2.2.2 When the mains power supply is configured in the cabinet, it shall comply with the provisions of GB 19517.

8 System Testing

8.1 Test Content The fiber optic monitoring system should undergo simulation testing, including temperature positioning error, temperature measurement error, vibration alarm testing, and monitoring platform testing.

8.2.1 Test Method

8.2.1.1 Within a single channel range, at least three representative test points (front, middle, and rear) should be selected on the optical cable under test to measure temperature. Positioning error test.

8.2.1.2 The test shall be performed according to the following steps.

a) Place the temperature measuring unit at the starting point of the pipe to be measured;

b) Select a test point and measure the actual distance from the test point to the starting point;

c) Heat the optical cable at the test point using a heating pad. The heating pad should be 0.5m to 1m wide, cover the optical cable, and be in close contact with the surface of the cable. The dough should be heated for 5 to 10 minutes.

d) Read the distance from the test point to the starting point displayed on the temperature measurement host.

8.2.2 Error Calculation The positioning error should be calculated according to formula (2).

8.2.3 Qualification Criteria The temperature positioning error at each test point should not exceed 1m.

8.3.1 Test Method

8.3.1.1 Within a single channel, at least three test points should be taken at different locations. the start point, the end point, and the middle point.

8.3.1.2 The test shall be performed according to the following steps.

a) Place the temperature measuring unit at the starting point of the pipe to be measured;

b) At the test point, use the optical cable pre-installed in the manhole or thermal well chamber for testing, and fabricate a continuous length of not less than 1m and a diameter of not less than Optical cable test rings smaller than 100mm;

c) Place the optical cable test ring into a constant temperature heating device and heat it. The temperature of the constant temperature heating device is set to 40°C, 60°C, and 80°C respectively. The temperature change during testing should not exceed 0.1°C/min;

d) Place the optical cable test ring into the testing device and wait for the temperature to stabilize. Then, read the temperature values from the constant temperature heating device and the temperature display on the temperature measuring host. Temperature value.

8.3.2 Error Calculation The temperature measurement error value should be calculated according to formula (3).

8.3.3 Qualification Criteria The arithmetic mean of the temperature measurement error at each temperature test point should not exceed 3°C.

8.4.1 Test Method

8.4.1.1 Within a single channel, at least three test points should be taken at different locations. the start point, the end point, and the intermediate point.

8.4.1.2 Each test point shall be tested by both mechanical application and manual application.

8.4.1.3 The rules for selecting testing tools are as follows:

a) The machinery should preferably be a small excavator with a bucket capacity of 0.1m^3 to 0.3m^3 and a bucket digging force of less than 60kN;

b) Ordinary manual digging tools such as shovels and picks should be selected for manual digging.

8.4.1.4 Mechanical testing shall be performed according to the following steps.

a) After the mechanical equipment reaches the designated position in the test section, shut off the flame for 15 minutes;

b) Simulate excavation work at a location 5m~10m from the outer edge of the pipeline;

c) At least two digging operations are required at each test location. The first digging operation lasts for 1 minute, after which the engine is shut down. The second digging operation lasts for 2 minutes, after which the engine is shut down. The time interval between two tests should not be less than 5 minutes.

8.4.1.5 For manual testing, a test pit should be dug at the top of the pipeline and dug continuously until an alarm is triggered. The digging depth should not be less than 0.5m from the top of the pipe.

8.4.2 Qualification Criteria All three vibration test points should be able to detect both third-party mechanical and manual excavation and trigger an alarm. The positioning error should meet the requirements of 6.2. Regulation.

8.5.1 Display Test

8.5.1.1 When zooming the map on the monitoring platform, the pipeline diagram and map location should be correctly mapped, and the identification information of key nodes should be clear and complete. Check whether the displayed content complies with the provisions of 5.5.2.1.

8.5.1.2 Select any pipe segment point to open the temperature curve, zoom in and out, and check if the curve display conforms to

5.5.2.2 and... The provisions of 5.5.2.3.

8.5.2 Alarm Test

8.5.2.1 Select one test point, heat the optical cable, record the alarm location, and check whether the alarm triggering complies with the provisions of 5.5.3.1.

8.5.2.2 Select one test pipe section, perform an excavation test, record the alarm location, and check whether the alarm triggering complies with the provisions of 5.5.3.3.

8.5.2.3 Select one test pipe section, perform vibration measurement and disarming operation, and then simulate an alarm event. No alarm should be triggered.

8.5.2.4 Simulate power failure, host failure, communication failure and optical cable damage respectively, and check whether the alarm triggering complies with the provisions of 5.5.3.4. For the above test items 8.5.2.5, the alarm notification function should comply with the provisions of 5.5.3.5.

8.5.3 Data Storage and Retrieval

8.5.3.1 When viewing the database through database visualization management software, check whether the data tables comply with the provisions of 5.5.4.1.

8.5.3.2 After the monitoring platform has been running for a period of time, check the data backup. The backup data file should be located in the specified location.

8.5.3.3 After completing all tests, export the report specified in 5.5.4.3.The report data should be standardized and complete.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

How to Buy GB/T 47547-2026

  1. 1Add to cart. Click the "Buy GB/T 47547-2026" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 47547-2026

$305.00

$260.00for partners