GB/T 47453-2026Measurement and assessment requirements for hand-transmitted vibration during on-orbit maintenance (English PDF)
在轨维修手传振动测量和判定要求
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for GB/T 47453-2026 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
April 30, 2026
Implementation date
November 1, 2026
Scope
GB/T 47453-2026 is the English-translated version of 在轨维修手传振动测量和判定要求.
GB/T 47453-2026 is the Chinese national standard for measuring, on the ground, the vibration that an on-orbit maintenance tool transmits into an astronaut's hand.
It specifies the measuring equipment - a microgravity simulation device, a differential pressure simulation device that reproduces the pressure across an extravehicular suit glove, a work object mounting platform, an instrumented measuring handle, the suit gloves and a palm adapter, and a data acquisition system - together with the measurement conditions and procedure, the judgment criteria and the measurement report.
Among the figures it fixes are a frequency range covering at least 6.3 Hz to 1250 Hz, a push force of 20 N ± 3 N and a grip force of 50 N ± 5 N. It covers two simulated conditions, extravehicular and in-cabin. Issued on 30 April 2026, it has applied since 1 November 2026.
Found what you need?
Document preview — GB/T 47453-2026
National Standard of the People's Republic of China
- ICS
- 13.160
- Classification
- V 70
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 4 Measuring equipment
- 5 Measurement conditions and measurement procedures
- 6 Judgment Requirements
- 7 Measurement Report
1 Scope
4 Measuring equipment
4.1 General Requirements
The measuring equipment includes external hand-transmitted vibration measuring equipment and internal hand-transmitted vibration measuring equipment. The external hand-transmitted vibration measuring equipment includes micro... Gravity simulation device, differential pressure simulation device, work object mounting platform, measuring handle, extravehicular activity suit gloves and hand adapter, and data acquisition system.
Figure 1 shows a schematic diagram of the external hand-transmitted vibration measurement equipment, which includes a system and other components. The internal hand-transmitted vibration measurement equipment includes a microgravity simulation device.
The equipment includes a mechanical support device, a work object mounting platform, a measuring handle, a subject's hand adapter, and a data acquisition system, as well as an in-cabin hand-operated transmission system.
A schematic diagram of the vibration measurement equipment is shown in Figure 2. The requirements for the measurement equipment are as follows.
a) The applicable frequency range should cover at least 6.3 Hz to 1250 Hz, including the measuring handle and palm adapter (containing the accelerometer). The natural frequency should be greater than twice 1250 Hz;
b) Dynamic force sensor (installed inside the measuring handle), static force sensor (installed inside the measuring handle), and acceleration sensor (installed separately).
The performance range and tolerance limits of the measuring handle (installed in the measuring handle and palm adapter) and the data acquisition system shall comply with GB/T 23716. The regulations;
c) Dynamic force sensors, acceleration sensors, static force sensors, and sensors used for barometric pressure measurement should all be calibrated or inspected and certified. Use within the expiry date;
d) The entire measurement system, consisting of the measuring handle, palm adapter (including the accelerometer), and data acquisition system, should be calibrated.
4.2 External manual vibration measurement equipment
4.2.1 Microgravity Simulation Device
The requirements for a microgravity simulation device are as follows.
a) The microgravity simulation device should allow the tested tool to move in six degrees of freedom (along the x, y, and z axes and around the x, y, and z axes).
The microgravity simulation (of the rotation) should have a follow-up range that meets the motion range requirements of the instrument being tested.
b) A microgravity simulation device should be constructed using a force balance method based on passive following. The schematic diagram of the microgravity simulation device is shown in Figure 3.
c) Unless otherwise specified, the rotation range of the microgravity simulation device around the x-axis and z-axis should be no less than -20° to 20°.
d) The microgravity simulation device should provide a connection interface for mounting the instrument under test, and after connection, the rotation of the instrument under test around the x-axis, y-axis, and z-axis should be achievable.
The axis should pass through the center of mass of the instrument being measured.
e) The coefficient of friction of the kinematic pairs in the six degrees of freedom of the microgravity simulation device should not be greater than 0.005.
f) The levelness of the x-axis and z-axis moving pairs of the microgravity simulation device should meet the measurement requirements.
g) The mass of the part of the microgravity simulation device that moves with the tool under test should be coordinated with the length of the suspension rope of the tool under test. To reduce the measurement... For measurement error, the mass of the part of the microgravity simulation device that moves with the tool under test should be as light as possible, preferably not exceeding the total mass of the tool under test.
The length should be 1/6 of the total length, and the length of the suspension rope should not be less than 200 mm.
h) The mechanical strength and stiffness of the microgravity simulation device should meet the measurement requirements.
4.2.2 Differential Pressure Simulation Device
When conducting extravehicular hand-transmitted vibration measurements, a pressure difference simulation device is used to simulate the pressure difference between the inside and outside of the gloves of an extravehicular spacesuit, with the following requirements.
a) The design, manufacture and inspection of the differential pressure simulation device chamber shall be carried out in accordance with the provisions of GB/T 150 (all parts).
b) A pressure measurement sensor should be configured, and a pressure parameter monitoring instrument should be set up to monitor the cabin pressure in real time.
c) The differential pressure simulation device should have pressure regulation and differential pressure maintenance functions after the extravehicular activity (EVA) gloves are installed, and the differential pressure setpoint should be adjustable.
The pressure range should ideally cover at least 29 kPa to 42 kPa, and the differential pressure setpoint for manual vibration measurement outside the cabin should be consistent with that under on-orbit conditions. Consistent.
d) The interfaces of the differential pressure simulation device mainly include the interface for the work object installation platform, the interface for the extravehicular spacesuit glove installation, and the interface for the microgravity model.
The proposed device mounting interface, measurement signal connection interface, etc., have the following interface requirements.
1) The differential pressure simulation device and the extravehicular activity (EVA) spacesuit gloves should be connected using a flexible, airtight connection and should not introduce additional stiffness or resistance to the measurement. Damping interference;
2) The height of the glove mounting interface on the extravehicular activity suit should be coordinated with the subject's operating posture to facilitate the subject's operation. Testing tools;
3) The installation interface of the microgravity simulation device should allow the tested tool to be in a position easily operated by the subject while suspended;
4) The measurement signal connection interface installed on the differential pressure simulation device cabin should meet the corresponding insulation and sealing requirements;
5) The mechanical strength and rigidity of each interface should be matched with the object being installed or connected.
e) The differential pressure simulation device chamber should be equipped with observation windows, the number and location of which should facilitate the subject's observation of the measured pressure inside the differential pressure simulation device. Tools and tasks.
f) The housing of the differential pressure simulation device should be reliably grounded.
g) After the differential pressure simulation device is assembled, an airtightness test should be conducted according to the differential pressure setting value used in the external manual vibration measurement. During pressure holding... The interval is 4 hours, and the pressure deviation during the pressure holding period should not exceed ±2 kPa.
4.2.3 Installation platform for the work object
The platform requirements for the task are as follows.
a) An interface for installing the work object should be provided;
b) The mechanical strength and stiffness should be matched with the work object.
4.2.4 Measuring Handle
Dynamic force sensors, acceleration sensors, and static force sensors are typically installed inside the handle of the tool under test to obtain data about the tool.
Dynamic force, acceleration, propulsive force, and gripping force at the handle. If the handle of the tool being measured cannot be fitted with a sensor, a dedicated measuring handle can be used instead. The requirements for the measuring handle are as follows.
a) The measuring handle consists of a handle body, a dynamic force measuring cap, a dynamic force sensor, an acceleration sensor, a static force measuring cap, and a static force sensor.
The sensor composition, the structure of the measuring handle, and the sensor arrangement are shown in Figure 4.
b) A symmetrical design should be adopted, with the dynamic force measuring cap and the static force measuring cap having the same shape and being symmetrically arranged on the main handle. Both sides of the body;
c) One acceleration sensor and no fewer than two dynamic force sensors should be installed between the dynamic force measuring cap and the handle body for measuring... Measure the acceleration and dynamic force on the finger or palm side;
d) At least two static force sensors should be installed between the static force measuring cap and the handle body to measure the subject's force on the measuring handle. The applied propulsive force and gripping force;
e) The accelerometer sensor is installed inside the dynamic force measurement cap, and the installation of the accelerometer sensor shall comply with the provisions of GB/T 14790.2.
The accelerometer should not be in rigid contact with the handle body;
f) The installation preload of the dynamic force sensor should be greater than the maximum dynamic force;
g) The total mass of the sensor and its fasteners should not exceed 5% of the mass of the tool being measured;
h) When a dedicated measuring handle is used instead of the handle of the tool being measured, the dedicated measuring handle should be identical in shape, size, and weight to the handle of the tool being measured.
The quantity and natural frequency should be consistent, and it should be rigidly connected to the instrument being tested.
4.2.5 Extravehicular activity suit gloves and hand adapters
The requirements for extravehicular activity suit gloves and hand adapters are as follows.
a) The material, quality, and structure of the extravehicular activity (EVA) spacesuit gloves should be consistent with their on-orbit condition. If conditions permit, actual EVA gloves can be used directly. The measurements were taken using Tianfu gloves;
b) The dimensions and shape of the palm adapter are shown in Figure 5. It should be made of rigid material, and its mass (including the accelerometer) should not exceed a certain limit. More than 15 g;
c) The installation of the accelerometer sensor in the palm adapter shall comply with the provisions of GB/T 14790.2;
d) The hand adapter should fit directly against the subject's palm.
Figure 6 shows a schematic diagram of the relative position of the palm adapter (located inside the exoplanetary suit glove). […]
4.2.6 Data Acquisition System
The data acquisition system is used to collect dynamic forces, static forces, and accelerations. Specific requirements are as follows.
a) The number of channels in the data acquisition system should meet the measurement requirements, ensuring that it can complete the measurement of dynamic force sensors, static force sensors, and acceleration sensors. Synchronous acquisition of sensor measurement signals;
b) It has the functions of acquiring, storing, processing, and analyzing time-domain data;
c) It has high-pass and low-pass filtering functions;
d) Features real-time display of propulsion and grip strength;
e) The sampling frequency should be no less than 12.5 kHz, the resolution should be no less than 16 bits, the measurement range should be no less than ±5 V, and other performance requirements (e.g.)
Characteristics such as frequency weighting, permissible error, dynamic range, sensitivity, linearity, overload capacity, and noise should not be lower than those specified in GB/T 23716. According to the regulations.
4.3 In-cabin manual vibration measurement equipment
The requirements for the manual vibration measurement equipment inside the cabin are as follows.
a) The requirements for the microgravity simulation device are the same as in 4.2.1; the requirements for the installation platform of the work object are the same as in 4.2.3; the requirements for the measuring handle are the same as in 4.2.4; and the data acquisition... The system requirements are the same as in 4.2.6.
b) The requirements for the palm adapter are as follows.
1) The dimensions and shape of the palm adapter are shown in Figure 5. It should be made of rigid material, and its mass (including the accelerometer sensor) should be considered. It should not exceed 15 g;
2) The installation of the accelerometer sensor in the palm adapter shall comply with the provisions of GB/T 14790.2;
3) The hand adapter should be in direct contact with the subject's palm. During in-cabin hand-transmitted vibration measurement, the measuring handle and the hand adapter should be positioned relative to each other. The location diagram is shown in Figure 7. Index number explanation. 1--Palm adapter (placed in the palm of the hand); 2--Measuring handle.
c) The requirements for mechanical support devices are as follows.
1) A differential pressure simulation device without extravehicular activity (EVA) gloves can be used as a mechanical support device for measurement. If there is no differential pressure... For simulation devices, specially designed mechanical support devices should be used for measurement;
2) A microgravity simulation device mounting interface should be provided, which should allow the tested tool to be suspended. Located in a position easily accessible to the subject;
3) An installation interface for the installation platform of the work object should be provided;
4) The mechanical strength and rigidity of each interface should be matched with the installation object.
5 Measurement conditions and measurement procedures
This document specifies the ground measurement and judgment requirements for hand-transmitted vibrations during on-orbit maintenance, including measurement equipment, measurement conditions and procedures, and judgment criteria. Request for measurement report.
This document applies to the ground measurement and assessment of hand-transmitted vibrations of on-orbit maintenance tools used by astronauts outside or inside the spacecraft, including hand-transmitted vibrations outside the spacecraft.
Two simulated operating conditions were used. dynamic measurement and in-cabin manual vibration measurement.
5.1 Measurement Conditions
5.1.1 Measurement Technology Status
The technical requirements for the tested tool and the work object are as follows.
a) The instrument under test should be consistent with the actual flight product used in orbit. Prototypes or simulators of the instrument under test are only permitted for use with the product.
Preliminary measurements were conducted during the initial research and development phase.
b) During the measurement process, the actual operating status of the instrument under test should be consistent with or cover the actual on-orbit usage status. state;
c) The working object of the tested tool should be consistent with the status of the working object in orbit.
5.1.2 Subjects
The requirements for participants are as follows.
a) For each testing tool, at least 5 adults should be selected as subjects, with a height of 1.60 m to 1.80 m and a weight of [missing information].
48 kg~75 kg;
b) The subject should use their dominant hand for measurement and be able to hold and operate the measuring tool correctly and skillfully.
5.1.3 Subject Posture
During on-orbit hand-transmitted vibration measurement, the subject should wear a hand adapter, hold the measuring handle, and stand vertically with the arm and torso positioned correctly.
The range is shown in Figure 8. Throughout the measurement, the upper arm, elbow, and forearm should not touch the body. The wrist is allowed to flex within 0° (midpoint). (position) ~40°, as shown in Figure 9.
5.1.4 Propulsion and grip strength
During the measurement, the subject is required to apply the following pushing force and gripping force to the measuring handle.
a) The subject should maintain a propulsive force of 20 N ± 3 N;
b) The subject should maintain a grip strength of 50 N ± 5 N.
5.2 Measurement Procedure
5.2.1 General Requirements
Unless otherwise specified, the measurement procedures for external and internal manual vibration measurements are the same, i.e., the first step is to perform the measurement as described in 5.2.2.
The first step is to prepare the measurements. The second step is to perform individual tool measurements as per 5.2.3. The third step is to perform work-condition-oriented measurements as per 5.2.4.
5.2.2 Measurement Preparation
The following preparations should be made before the measurement begins.
a) Check the technical condition of the tool being tested and the object being worked on.
b) In accordance with GB/T 23716, conduct on-site inspections to verify whether the measurement data from the measuring handle, hand adapter, and data acquisition system are valid. normal.
c) The following preparations should also be made for external manual vibration measurements.
1) Check the working condition of the microgravity simulation device, pressure difference simulation device, and extravehicular activity (EVA) spacesuit gloves, and ensure that the microgravity simulation device is functioning properly.
Both the spacesuit and the extravehicular activity (EVA) gloves are reliably connected to the differential pressure maintaining device.
2) Securely fix the tool under test inside the microgravity simulation device;
3) Secure the hand adapter to the subject's hand (located inside the exoplanet glove).
4) Run the differential pressure simulation device to keep its differential pressure consistent with the on-orbit condition and maintain that differential pressure continuously during the measurement.
d) The following preparations should also be made for manual vibration measurement inside the cabin.
1) Check the working status of the microgravity simulation device and the mechanical support device, and ensure that the microgravity simulation device and the mechanical support device are in good working order. Establish a reliable connection;
2) Securely fix the tool under test inside the microgravity simulation device;
3) Secure the hand adapter to the subject's hand.
5.2.3 Instruments measured individually
Individual measurements using tools should be performed according to the following requirements.
a) Ensure a reliable connection between the testing tool and the operation interface of the work object;
b) Configure the tool to run independently. Once the tool under test begins operation, data acquisition should be performed synchronously. During the measurement period, the subject should not... The instrument being tested should be intervened or other interventional procedures should be performed.
c) Measure the dynamic forces F< sub>fc< /sub>, F< sub>pc< /sub> and accelerations a< sub>fc< /sub>, a< sub>pc< /sub> at the 1/3 octave band dynamic range on the finger and palm sides of the handle of the tool under test, respectively. Measurement;
d) At the start of each measurement day, the tool should be measured once individually.
5.2.4 Measurement based on operating conditions
Measurements taken for operational conditions should be performed according to the following requirements.
a) Reliably connect the operating interface of the tool under test to the work object.
b) Subjects should operate the test instrument as follows.
1) During extravehicular hand-transmitted vibration measurement, the subject wears an extravehicular spacesuit glove, holds the handle of the test tool stably, and runs the test instrument. tool;
2) During the in-cabin hand-transmitted vibration measurement, the subject holds the handle of the test tool stably with his bare hand and runs the test tool;
3) The subject's posture during the measurement should follow the provisions of 5.1.3, and the propulsion force and grip force should be controlled according to the provisions of 5.1.4.
c) Once the tool under test starts running, collect data synchronously according to the following requirements.
1) Collect dynamic force F_ft, F_pt, and acceleration at 1/3 octave band on the finger and palm sides of the handle of the test tool for each subject. a ft, apt;
2) Collect the unweighted acceleration ahi at the palm adapter of each subject;
3) Data acquisition at the handle of the tool under test and at the palm adapter should be performed simultaneously.
d) Subjects should rest for at least 5 minutes between each valid measurement.
e) Repeat steps a) to d) until each subject has completed at least 10 valid measurements.
f) If the tool under test has multiple operating conditions, the measurement should cover all operating conditions, and each operating condition should be performed according to steps a) to e). Line measurement.
Note 1. The measurement cycle is determined according to the specific situation, and generally a complete measurement does not exceed 1 minute.
Note 2. Measurements that are comparable or repeatable across multiple measurements are considered valid measurements.
6 Judgment Requirements
6.1 Calculation of Vibration Energy Absorption
The calculation method for vibration energy absorption is as follows.
a) Based on F< sub>fc< /sub>, F< sub>pc< /sub>, and accelerations a< sub>fc< /sub>, a< sub>pc< /sub>, and a< sub>pc< /sub>, obtained from 5.2.3, calculate the finger values according to formulas (A.1) and (A.2) in Appendix A.
The mechanical impedance of the side handle's added mass DPMI fc (omega) and the mechanical impedance of the palm-side handle's added mass DPMIpc (omega).
b) Based on the dynamic forces F< sub>ft< /sub> and F< sub>pt< /sub> and accelerations a< sub>ft< /sub> and apt obtained in 5.2.4, calculate the dynamic forces F< sub>ft< /sub> and F< sub>pt< /sub> and accelerations a< sub>ft< /sub> and apt respectively according to formulas (A.3) and (A.4) in Appendix A.
Calculate the finger-side arm-handle coupling mechanical impedance DPMIft (omega) and the palm-side arm-handle coupling mechanical impedance DPMIpt (omega).
c) Calculate the finger mechanical impedance DPMI f(omega) and the palm mechanical impedance using formulas (A.5) and (A.6) in Appendix A, respectively. DPMIp (omega).
d) Calculate the mechanical resistance DPMIhand (omega) of the arm according to formula (A.7) in Appendix A.
e) Calculate the x-axis, y-axis, and z-axis (coordinates) of the k-th valid measurement for the r-th subject according to formula (A.8) in Appendix A.
The diagram showing the relationship between the reference axis and the handle of the measured tool (as shown in Figure 10) illustrates the uniaxial vibration energy absorption VPA rkx and VPA rky. And VPA rkz.
6.2 Calculation of Daily Vibration Exposure
The method for calculating daily vibration exposure is as follows. […]
6.3 Judgment Method
6.3.1 Vibration energy absorption and daily vibration exposure should be used together as the judgment indicators, and the vibration energy absorption of the tested tool should be calculated separately.
Arithmetic mean ----- Arithmetic mean of VPA and daily vibration exposure ----- A (8).
The on-orbit manual vibration judgment limit of the tested tool shall be determined jointly with the task-proposing unit and the user unit.
The measurement report should include the following.
a) Measuring mechanism;
b) Measurement date;
c) Basic information about the instrument under test (submitting organization, product name, product code, etc.);
d) Measuring equipment;
e) Operating conditions;
f) Measurement conditions (subject information, propulsive force, and grip strength, etc.);
g) Vibrational energy absorption - VPA;
h) Daily vibration exposure - ----A (8).
7 Measurement Report
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
How to Download GB/T 47453-2026
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 47453-2026
$420.00