GB/T 47065-2026Surface chemical analysis - Surface characterization - Measurement of the lateral resolution of a confocal fluorescence microscope (English PDF)
表面化学分析 表面表征 共聚焦荧光显微镜横向分辨的测量
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for GB/T 47065-2026 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Recommended
Issue date
January 28, 2026
Implementation date
August 1, 2026
Scope
GB/T 47065-2026 is the English-translated version of 表面化学分析 表面表征 共聚焦荧光显微镜横向分辨的测量.
GB/T 47065-2026 — This document describes a method for determining the transverse aspect ratio of confocal fluorescence microscopy (CFM) by imaging objects much smaller than expected to be resolved. Methods for distinguishing between different types of objects.
Found what you need?
Document preview — GB/T 47065-2026
National Standard of the People's Republic of China
- ICS
- 71.040.40
- Classification
- G 04
Issued by: State Administration for Market Regulation
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative References
- 3 Terms and Definitions
- 4 Symbols and Abbreviations
- 5 Overview
- 6 Measuring lateral resolution by imaging small objects 3.
- Appendix A (Informative). Sample Preparation, Data Examples, and Data Analysis
- References
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".
Drafting.
This document is equivalent to ISO 18337:2015 "Surface chemical analysis and surface characterization - lateral resolution confocal fluorescence microscopy".
Measurement".
This document adds a chapter on "Normative References".
Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.
This document was proposed and is under the jurisdiction of the National Technical Committee on Standardization of Surface Chemical Analysis (SAC/TC608).
Introduction
Confocal fluorescence microscopy (CFM) is a laser scanning confocal microscopy (LSCM) that operates in fluorescence imaging mode, utilizing...
It can obtain fluorescence images of samples. Fluorescence is emitted by molecules or solid lattices during the relaxation process after photon absorption and electronic excitation.
Fluorescence wavelength, intensity, and spectral shape are related to the electronic structure of materials; therefore, fluorescence spectroscopy and its imaging techniques are valuable for chemical characterization and analysis.
CFM is extremely useful in optical imaging and spectroscopy. Its high spatial resolution is advantageous for analyzing nanomaterials and thin films.
Analysis. Spatial resolution is one of the most important performance indicators of CFM.
Spatial resolution of a technology refers to its maximum distinguishability between two adjacent target objects; manufacturers typically define it in different ways.
This value is characterized. The spatial resolution of CFM is characterized by lateral resolution and axial resolution; the values of these two are different and not necessarily interdependent.
The document provides a convenient and effective method for measuring the lateral resolution of CFM.
Surface chemical analysis and surface characterization Measurement of lateral resolution by confocal fluorescence microscopy
1 Scope
This document describes a method for determining the transverse aspect ratio of confocal fluorescence microscopy (CFM) by imaging objects much smaller than expected to be resolved.
Methods for distinguishing between different types of objects.
2 Normative references
This document has no normative references.
3 Terms and Definitions
The following terms and definitions apply to this document.
Point spread function the response of an imaging system to a point light source or a point object.
Lateral resolution
Measurements that can reliably distinguish compositional changes within the plane of the sample surface or within a plane perpendicular to the axis of the imaging optics.
distance.
Note. See reference [1].
4 Symbols and Abbreviations
The following symbols and abbreviations apply to this document.
FWHM. Half-maximum
NA. Numerical Aperture QD. Quantum Point
5 Overview
5.1 Background Information
Laser scanning confocal microscopy (LSCM) uses a well-focused laser beam to scan a sample and records the light intensity at each pixel to form a microgram.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download GB/T 47065-2026
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 47065-2026
$255.00