GB/T 46972-2026Nanotechnology - Measurement method for the morphology and size of exosomes - Atomic force microscopy (English PDF)

纳米技术 外泌体形貌和尺寸测量 原子力显微术

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for GB/T 46972-2026 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

January 28, 2026

Implementation date

August 1, 2026

Scope

GB/T 46972-2026 is the English-translated version of 纳米技术 外泌体形貌和尺寸测量 原子力显微术.

GB/T 46972-2026 is the Chinese standard "Nanotechnology - Measurement method for the morphology and size of exosomes - Atomic force microscopy". Its scope clause reads: This document describes a method for measuring the morphology and size of exosomes using atomic force microscopy in tapping mode.

This document applies to the measurement of exosome morphology and size in a liquid environment; other extracellular vesicles should be measured using the same method. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 46972-2026

National Standard of the People's Republic of China

ICS
19.020
Classification
G 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • Introduction
  • 1.Scope
  • 2 Normative References
  • 3.Terms and Definitions
  • 4.Working principle of liquid phase environment in atomic force microscopy
  • 5.Reagents and Materials
  • 6.Instruments and Equipment
  • 7.Measurement Preparation
  • 8 Sample Preparation
  • 9.Sample Measurement
  • 10 Data Processing
  • 11 Measurement Data Results
  • 12 Reports
  • Appendix A (Informative) Plasma Cleaning
  • Appendix B (Informative) Mica Substrate Modification (APTES Method)
  • Appendix C (Informative) Example of Exosome Morphology Measurement
  • Appendix D (Informative) Exosome Measurement Report Format

1 Scope

This document describes a method for measuring the morphology and size of exosomes using atomic force microscopy in tapping mode.

This document applies to the measurement of exosome morphology and size in a liquid environment; other extracellular vesicles should be measured using the same method.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.

For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.

This document.

GB/T 6682-2008 Specifications and test methods for water used in analytical laboratories

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Extracellular vesicles (EVs)

Membrane particles with a lipid bilayer structure released from cells carry and transfer phospholipids and proteins derived from parent cells.

Including nucleic acids and other contents, they mediate intercellular signal communication and substance exchange.

3.2 exosome

Extracellular structures with membrane structures and generally a size of 30nm to 150nm are produced by "endocytosis, fusion, and release" from living cells.

Vesicles.

3.3

By controlling the distance between the probe and the sample surface through detecting the interaction forces (attractive or repulsive forces) between the probe and the sample surface, surface parameters can be obtained.

Scanning probe microscopy for morphology.

[Source. GB/T 27760-2011, 3.1]

3.4 Tapping mode

One operating mode of atomic force microscopy involves driving a microcantilever via a small piezoelectric element mounted within the microscope's probe holder.

The probe oscillates near its resonant frequency, causing the probe tip to intermittently contact the sample surface, thus achieving morphological imaging.

Note 1.Atomic force microscopes have different operating modes, namely contact mode, non-contact mode and tapping mode.

Note 2.In contact mode, the needle tip is always in contact with the sample, and there is a repulsive force between the needle tip and the sample, which is suitable for highly elastic models or samples that are not easily deformed.

Note 3.In non-contact mode, the needle tip never contacts the sample. The interaction between the needle tip and the sample is a long-range force, and the resolution decreases when the distance between the needle tip and the sample is relatively long.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 46972-2026

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 46972-2026

$300.00