Valid

GB/T 46856-2025Determination of the emission of certain volatile organic compounds from juvenile products (English PDF)

婴童用品挥发性有机物释放量的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for GB/T 46856-2025 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 31, 2025

Implementation date

June 1, 2026

Scope

GB/T 46856-2025 is the English-translated version of 婴童用品挥发性有机物释放量的测定.

GB/T 46856-2025 is the Chinese national standard that describes how the emission of certain volatile organic compounds from juvenile products is measured.

It covers naphthalene, methyl acrylate, methyl methacrylate, 2-phenyl-2-propanol, formamide, benzene, toluene, ethylbenzene and the three xylene isomers in finished products, materials and components.

The sample is placed in a sampling bag or a climate chamber under simulated conditions of use, the released compounds are collected on a tenax tube and measured by thermal desorption gas chromatography mass spectrometry, and quantification uses the external standard method.

The standard lists the reagents and their purities, the instruments and equipment, and the sampling steps, beginning with how the exposed surface area of a product is calculated.

It has no normative references. It was issued on 31 December 2025 and has applied since 1 June 2026.

Found what you need?

Document preview — GB/T 46856-2025

National Standard of the People's Republic of China

ICS
97.190
Classification
Y 57

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions4
  • 4 Principle5
  • 5 Reagents and materials5
  • 6 Instruments and equipment6
  • 7 Sampling steps7
  • 8 Instrumental analysis11
  • 9 Specimen data processing13
  • 10 Method detection limit13
  • 11 Precision14
  • 12 Test report14
  • Annex A (informative) Calculation of exposed surface area of juvenile products and components15
  • Annex B (normative) Data on the target substances measured19
  • Annex C (informative) Chromatogram of the target analyte20
  • Bibliography21

1 Scope

This document describes the testing methods for the release of volatile organic compounds (VOCs) in juvenile products.

This document applies to the determination of volatile organic compounds such as naphthalene, methyl acrylate, methyl methacrylate, 2-phenyl-2-propanol, formamide, benzene, toluene, ethylbenzene, m-xylene, p-xylene, and o-xylene in finished juvenile products, materials, and components.

2 Normative references

This document has no normative references.

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

3.1 Area of exposure

The total area of all exposed surfaces of the sample that are in direct contact with ambient air during use.

NOTE: This includes the contact surfaces of the main structure, accessories, and detachable parts, but excludes internal areas that are not in contact with ambient air.

3.2 Area load factor

The ratio of the area of exposure of the sample to the volume of the sampling bag (climate chamber).

NOTE: The unit is square meters per cubic meter (m2/m3).

3.3 Air exchange rate

The ratio of the amount of clean air entering the climate chamber per unit time to the volume of the climate chamber. [Source: GB/T 31107-2014, 3.5]

4 Principle

Place the sample in a sampling bag or climate chamber. Simulate sample usage environment conditions to test. After a specified time, use a sampling tube to collect the released volatile organic compounds. Use thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) to determine the volatile organic compounds. Use the external standard method to perform quantification.

NOTE: This document provides methods for detecting volatile organic compound (VOC) release using the sampling bag method and the climate chamber method. The results obtained from these two methods are not necessarily correlated. Users shall choose the appropriate method based on their specific application scenario.

5 Reagents and materials

Unless otherwise specified, all reagents used are analytically pure.

5.1 Naphthalene (CAS No. 91-20-3). purity >= 98%.

5.2 Methyl acrylate (CAS No. 96-33-3). purity >= 98%.

5.3 Methyl methacrylate (CAS No. 80-62-6). purity >= 98%.

5.4 2-Phenylon-2-propanol (CAS No. 617-94-7). purity >= 98%.

5.5 Formamide (CAS No. 75-12-7). purity >= 98%.

5.6 Benzene (CAS No. 71-43-2). purity >= 98%.

5.7 Toluene (CAS No. 108-88-3). purity >= 98%.

5.8 Ethylbenzene (CAS No. 100-41-4). purity >= 98%.

5.9 m-Xylene (CAS No. 108-38-3). purity >= 98%.

5.10 p-Xylene (CAS No. 106-42-3). purity >= 98%.

5.11 o-Xylene (CAS No. 95-47-6). purity >= 98%.

5.12 Methanol. chromatographically pure or higher.

5.13 11 volatile organic compound mixed standard stock solution (1000 µg/mL). accurately transfer an appropriate number of standard products (5.1~5.11) into a 10 mL volumetric flask. Dilute to volume with methanol (5.12). Prepare a standard stock solution with a concentration of 1000 µg/mL.

NOTE: The standard stock solution shall be stored sealed in a refrigerator at 0°C~4°C. The shelf life is 3 months.

5.14 Mixed working solution. transfer an appropriate volume of the standard stock solution (5.13). Prepare a series of standard solutions with methanol to prepare mixed working solutions with concentrations of 10 µg/mL and 100 µg/mL.

5.15 Helium. purity >= 99.999%.

5.16 Nitrogen. purity >= 99.999%.

6 Instruments and equipment

6.1 Gas chromatography-mass spectrometry (GC-MS).

6.2 Thermal desorption unit. capable of performing two-stage thermal desorption on the adsorption sampling tube and carrying the desorbed gas into the gas chromatograph using a carrier gas. Desorption temperature, desorption time, and flow rate are adjustable. The cold trap enables rapid heating. All gas tubing within the instrument, including the connection between the thermal desorption unit and the gas chromatograph, shall be made of silanized stainless steel.

6.3 Sampling tube. tenax tube, filled with at least 200 mg of adsorbent. Both ends of the sampling tube are sealed with metal nuts and PTFE rings.

6.4 Sampling device and components. the tubing shall be made of polytetrafluoroethylene (PTFE), with an outer diameter of phi8 mm or less (inner diameter of phi4 mm) and a length of 50 cm or less. If the diameters of the tubing and collection tube, or the tubing and sampling bag are inconsistent, flexible tubing can be used to connect them. Ensure that all pipes and joints do not absorb or release gas, and that there are no gas leaks at the connections. Before use, the sampler shall be heated in clean air at 100°C for approximately 24 h. The sampler shall be able to accurately control the sampling volume within a flow rate range of 50 mL/min~1200 mL/min when the sampling tube is installed. The sampling flow rate shall be calibrated periodically using a flow meter. The error shall be less than 5%.

6.5 Constant temperature drying oven. temperature control range is 20°C~100°C; allowable deviation. ±2°C.

6.6 Temperature and humidity chamber. temperature control range is 20°C~80°C; allowable deviation. ±2°C. Relative humidity adjustment range is 30%~80%; allowable deviation. ±5%.

6.7 Sampling bags. low adsorption and low gas permeability; do not release interfering substances; generally made of fluoropolymer film; equipped with a PTFE valve that can be opened and closed, and a removable sealing strip. The blank value of the sampling bag shall be lower than the method detection limit of the target analyte in this document. Sampling bags are available in different sizes, such as 5 L, 10 L, 50 L, 100 L, 1000 L, etc.

6.8 Climate Chamber. the interior walls and piping of the climate chamber shall be manufactured using materials with low release, low permeability, low adsorption, and VOC inertness. All joints in the climate chamber (except for the doors) shall be sealed. The air exchange rate n is 0.2 h^-1~2.0 h^-1; the relative error shall not exceed ±3%. Allowable temperature deviation. ±2°C; allowable relative humidity deviation. ±5%. The blank value of the climate chamber shall be lower than the method detection limit of the target substance in this document. Climate chambers are available in different specifications, such as 60 L, 1 m³, 5 m³, etc.

6.9 Flow meter. soap film flow meter or electronic flow meter, used for gas flow calibration of sampler, with an indication error <= ±1%.

6.10 Microsyringe. 5 µL or 10 µL.

6.11 Steel ruler or measuring tape. accuracy is not less than 1 mm.

7 Sampling steps

7.1 Calculation of sample area of exposure

For juvenile products and parts with regular geometric shapes such as cubes, spheres, and cones, the area of exposure shall be calculated according to the mathematical formula for area of exposure. If the sample has an irregular or complex shape, it shall be simplified to a standard geometric shape (such as a cuboid, cylinder, or sphere) or decomposed into multiple geometric units for calculation. For example, helmets in protective equipment shall be simplified to a spherical crown, and knee pads and elbow pads shall be simplified to a cuboid for calculation.

The surface area of components in the finished product that do not release volatile organic compounds is not included in the total area of exposure. If the component is detachable, it may be excluded from the testing scope when conducting finished product testing.

NOTE: Such as components made entirely of inorganic materials such as metal, glass, and ceramics, without added coatings, adhesives, or other components that may release VOCs. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

How to Download GB/T 46856-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 46856-2025

$300.00