GB/T 45895-2025Anaesthetic and respiratory equipment - Dimensions of non-interchangeable screw-threaded (NIST) low-pressure connectors for medical gases (English PDF)

麻醉和呼吸设备 医用气体不可互换螺纹(NIST)低压接头的尺寸

Preview PDF

This is a limited preview

Buy now to download the full PDF (10 pages)

Need quotation for your management?

Get a formal quotation for GB/T 45895-2025 in 30 minutes.

Issued by

State Administration for Market Regulation, Standardization Administration of China

Level / Type

National · Recommended

Issue date

August 1, 2025

Implementation date

August 1, 2026

Scope

GB/T 45895-2025 is the English-translated version of 麻醉和呼吸设备 医用气体不可互换螺纹(NIST)低压接头的尺寸.

GB/T 45895-2025 — This document specifies the intended use in medical gas systems with a maximum working pressure not exceeding 1400 kPa and an absolute pressure not exceeding 60 kPa.

Dimensions, configurations, and markings of non-interchangeable threaded (NIST) fittings for vacuum systems.

This document applies to medical gases [oxygen, nitrous oxide (laughing gas), medical air, helium, carbon dioxide, xenon, the special NIST connector for use with [standard gas mixture, 93% oxygen, air for driving surgical instruments, nitrogen for driving surgical instruments, vacuum].

Note 1.GB/T 46042 specifies low-pressure hose assemblies for medical gases and vacuum. This document does not specify manufacturer-supplied information because the information used by NIST connectors permanently installed on each medical device is determined by each individual.

Provided by medical device manufacturers. Note 2.Environmental impacts are addressed in the standards for medical devices used with NIST connectors.

Found what you need?

Document preview — GB/T 45895-2025

National Standard of the People's Republic of China

ICS
11.040.10
Classification
C 46

Issued by: State Administration for Market Regulation, Standardization Administration of China

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 NIST Connector Dimensions and Configurations
  • 5 Mark
  • 6 Marking durability test
  • Reference

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

This document is modified to adopt ISO 18082:2014 "Non-interchangeable threaded (NIST) low-pressure connectors for medical gases for anesthetic and respiratory equipment" size".

This document adds a chapter on "Normative References".

The technical differences between this document and ISO 18082:2014 and their reasons are as follows.

--- The marking durability test method (see Chapter 6) has been changed to adapt to my country's technical conditions.

The following editorial changes have been made to this document.

--- Incorporated the amendments to ISO 18082:2014/Amd1.2017, the outer margins of the clauses involved are indicated by vertical Double lines (||) are marked;

--- Replaced ISO 5359 with the informative reference GB/T 46042 (see Chapter 1);

---NIST body diameter and tolerance "A7" "Dimension D" changed from "1" to "14" (see Table 2);

--- Changed the drawing perspective (see Figure 3);

---Deleted some footnotes.

Introduction

This standard is developed to meet the requirements of medical devices that are safely connected and supply medical gases to patients or drive gases to medical equipment.

Medical gases are usually stored in cylinders/cryogenic containers or produced on site; various devices can be installed between the gas source and such medical equipment.

Devices (such as pressure regulators, hose assemblies, flow meter assemblies, ventilators, anesthesia workstations). Each interface requires a gas-specific interface.

Ensure that medical gases are delivered to the patient correctly.

However, as the standards of various countries continue to increase and update, it may eventually lead to the danger of cross-mixing of components used for different gases.

Therefore, this document selects the medical gas non-interchangeable thread (NIST) fitting system to standardize the domestic thread fitting system to avoid cross Dangers of mixing.

Anesthesia and respiratory equipment medical gases are not interchangeable Dimensions of threaded (NIST) low-pressure fittings

1 Scope

This document specifies the intended use in medical gas systems with a maximum working pressure not exceeding 1400 kPa and an absolute pressure not exceeding 60 kPa.

Dimensions, configurations, and markings of non-interchangeable threaded (NIST) fittings for vacuum systems.

This document applies to medical gases [oxygen, nitrous oxide (laughing gas), medical air, helium, carbon dioxide, xenon, the special NIST connector for use with [standard gas mixture, 93% oxygen, air for driving surgical instruments, nitrogen for driving surgical instruments, vacuum].

Note 1.GB/T 46042 specifies low-pressure hose assemblies for medical gases and vacuum.

This document does not specify manufacturer-supplied information because the information used by NIST connectors permanently installed on each medical device is determined by each individual.

Provided by medical device manufacturers.

Note 2.Environmental impacts are addressed in the standards for medical devices used with NIST connectors.

2 Normative references

This document has no normative references.

3 Terms and Definitions

The following terms and definitions apply to this document.

gas-specific

It has the characteristic of preventing the connection between different gas facilities or vacuum facilities.

[Source. GB/T 44059.1-2024, 3.17] 3.2 medical gas any gas or substance used for the administration of a patient or for the application of a surgical instrument for the purpose of anesthesia, treatment, diagnosis or prevention of disease Mixed gas.

[Source. GB/T 4999-2003, 1.1.1, modified] 3.3 NIST connector A set of outer and inner joints with different diameters and left-hand or right-hand threads are connected to the matching joints of each specific gas to Keep the gas specific.

4 NIST Connector Dimensions and Configurations

The configuration of the NIST connector should comply with the requirements of Table 1.

The dimensions of the NIST body, mastoid connector, and nut shall conform to Figures 1, 2, 3, and 4 and Tables 2, 3, and 4.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

How to Download GB/T 45895-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 45895-2025

$225.00