GB/T 45772-2025Surface chemical analysis - Electron spectroscopies - Procedures for identifying, estimating and correcting for unintended degradation by X-rays in a material undergoing analysis by X-ray photoelectron spectroscopy (English PDF)

表面化学分析 电子能谱 X射线光电子能谱分析中X射线致材料非预期损伤的识别、评估和校正程序

Preview PDF

This is a limited preview

Buy now to download the full PDF (14 pages)

Need quotation for your management?

Get a formal quotation for GB/T 45772-2025 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

June 30, 2025

Implementation date

January 1, 2026

Scope

GB/T 45772-2025 is the English-translated version of 表面化学分析 电子能谱 X射线光电子能谱分析中X射线致材料非预期损伤的识别、评估和校正程序.

GB/T 45772-2025 — This document specifies the non-predicted changes in the elemental composition or chemical state of a sample caused by X-ray irradiation in X-ray photoelectron spectroscopy (XPS) analysis.

Requirements for methods of identification, assessment and correction of chronic injuries. This document only applies to unexpected damage caused by X-rays, which results in a decrease or increase of less than 30% in the peak intensity of the photoelectron spectrum.

This document does not involve comparisons between different types of materials, nor does it address the mechanism, depth, or chemical nature of the damage.

Found what you need?

Document preview — GB/T 45772-2025

National Standard of the People's Republic of China

ICS
71.040.40
Classification
G 04

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Symbols and abbreviations
  • 5 Sample damage
  • 5.1 Cause of damage
  • 5.2 Sample damage
  • 5.3 Methods for identifying and correcting impairments
  • 5.4 Assessing the likelihood of injury
  • 5.5 Damage Report
  • 5.6 Recommended procedures to minimize injury
  • 5.7 Impact of pollution
  • Appendix A (Informative) Materials reported to have been damaged during analysis
  • Appendix B (Informative) Injury Case
  • Appendix C (Informative) Correction of contamination layer
  • Reference

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

This document is equivalent to ISO 18554:2016 "Surface chemical analysis, X-ray photoelectron spectroscopy, X-ray induced Procedures for the identification, evaluation, and correction of unexpected damage to materials.

This document adds a chapter on "Normative References".

Introduction

X-ray photoelectron spectroscopy (XPS) usually uses soft X-rays as the excitation source to measure the photoelectrons and Auger electrons emitted from the sample surface.

In its most widely used mode, the X-ray flux intensity is low and the distribution range is large. Therefore, this technique is usually considered to be used for surface However, since its use as a surface analysis technique, reports have shown that the elemental composition of the sample surface may change during the test. For some materials, it is necessary to consider the elemental composition of the sample surface during the test.

The damage caused by the XPS analysis is corrected when possible[1]~[4].

Methods for identifying, evaluating, and correcting unintended X-ray-induced damage to materials.

Surface chemical analysis Electron spectroscopy X-ray photoelectron Unexpected damage to materials caused by X-rays in energy spectrum analysis Identification, Assessment and Correction Procedures

1 Scope

This document specifies the non-predicted changes in the elemental composition or chemical state of a sample caused by X-ray irradiation in X-ray photoelectron spectroscopy (XPS) analysis.

Requirements for methods of identification, assessment and correction of chronic injuries.

This document only applies to unexpected damage caused by X-rays, which results in a decrease or increase of less than 30% in the peak intensity of the photoelectron spectrum.

This document does not involve comparisons between different types of materials, nor does it address the mechanism, depth, or chemical nature of the damage.

2 Normative references

This document has no normative references.

3 Terms and Definitions

The following terms and definitions apply to this document.

region

Select the portion of the photoexcitation for spectral acquisition and analysis.

NOTE 1 The region may be chosen because it contains the major or minor peak for a given element, or because it represents the shape or slope of the background in that energy range, e.g. a fine scan.

NOTE 2 This use of region is not to be confused with analysis region.

timezero

The start time of X-ray irradiation of the sample.

4 Symbols and abbreviations

The following symbols and abbreviations apply to this document.

AZ. The linear rate of change of It,Z derived from the degradation of a given element or chemical state C. quantitatively calculated percentage of contaminated carbon atoms Dcontamination. thickness of the contamination layer on the sample surface DI. Damage Index E. Kinetic energy of the detected electron, in eV FWHM. Half Peak Width IZ,corrected. The intensity of a given photoelectron peak after the formation of the corrected contamination layer IZ,measured. The measured intensity of a given photoelectron peak affected by the contamination layer I0,Z. Undamaged photoelectron intensity of a given element Z or chemical state Z If,S. Final photoelectron intensity of a given element in the test spectrum

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

How to Download GB/T 45772-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 45772-2025

$360.00