GB/T 44474-2024Determination of inrush current characteristics of lighting products (English PDF)
照明产品浪涌电流特性的测定
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for GB/T 44474-2024 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
October 26, 2024
Implementation date
May 1, 2025
Scope
GB/T 44474-2024 is the English-translated version of 照明产品浪涌电流特性的测定.
GB/T 44474-2024 — This document describes a method based on measurement and calculation to determine the surge current of single and/or multiple lighting products of the same type.
Specific characteristics of the flow. Lighting products include. --- Light sources with integrated control devices; ---Control device; ---Lighting fixtures. The surge current characteristics that have been determined are. ---Peak surge current; ---Surge current pulse duration.
This document applies to lighting products connected to a low voltage power grid of AC 220V 50Hz. NOTE. In clause 6, the method applies reference values of reference (line) inductance and reference (short-circuit) peak current, which reflect the voltage at 220 VAC. Typical situation in installation.
Found what you need?
Document preview — GB/T 44474-2024
National Standard of the People's Republic of China
- ICS
- 29.140.01
- Classification
- K 70
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Symbols and abbreviations
- 5 General Notes on Measurement
- 6 Inrush current measurement
- 7 DC Method
- 7.1 Measuring device
- 7.2 Determining the value of the adjustable resistor
- 7.3 Measurement and calculation of surge current characteristics
- 8 Alternative Communication Methods
- 8.1 General
- 8.2 Determining the value of the adjustable resistor
- 8.3 Measurement and calculation of surge current characteristics
- 9 Other Alternative Methods
- Appendix A (Informative) Application of Surge Current Characteristics
- A.1 Overview
- A.2 Matching of DUT surge current characteristics with switch or MCB specifications
- Reference
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.
This document is modified to adopt IEC 63129:2020 "Determination of surge current characteristics of lighting products".
The technical differences between this document and IEC 63129:2020 and their reasons are as follows.
---Change AC 230V 50/60Hz to AC 220V 50Hz to suit my country's voltage.
1 Scope
This document describes a method based on measurement and calculation to determine the surge current of single and/or multiple lighting products of the same type.
Specific characteristics of the flow. Lighting products include.
--- Light sources with integrated control devices;
---Control device;
---Lighting fixtures.
The surge current characteristics that have been determined are.
---Peak surge current;
---Surge current pulse duration.
This document applies to lighting products connected to a low voltage power grid of AC 220V 50Hz.
NOTE. In clause 6, the method applies reference values of reference (line) inductance and reference (short-circuit) peak current, which reflect the voltage at 220 VAC.
Typical situation in installation.
2 Normative references
This document has no normative references.
3 Terms and Definitions
The following terms and definitions apply to this document.
A two-terminal thyristor having substantially the same switching characteristics in the first and third quadrants of the current-voltage characteristic curve body tube.
A three-terminal thyristor having substantially the same switching characteristics in the first and third quadrants of the current-voltage characteristic.
body tube.
circuit-breaker
It can connect, carry and disconnect current under normal circuit conditions; carry the specified overcurrent within the specified time and can A mechanical switching device that connects and disconnects current under circuit conditions (such as various short-circuit conditions).
source)
A unit connected between a power source and at least one light source for providing a rated voltage or rated current to the light source, which may consist of one or more Independent components.
Note 1.The control device may include triggering, dimming, power factor correction, radio interference suppression and more control functions.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
How to Download GB/T 44474-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 44474-2024
$300.00