Valid

GB/T 4325.15-2013Methods for chemical analysis of molybdenum - Part 15: Determination of sodium content - Flame atomic absorption spectrometry (English PDF)

钼化学分析方法 第15部分:钠量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 4325.15-2013 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 9, 2013

Implementation date

February 1, 2014

Scope

GB/T 4325.15-2013 is the English-translated version of 钼化学分析方法 第15部分:钠量的测定 火焰原子吸收光谱法.

GB/T 4325.15-2013 is the Chinese standard "Methods for chemical analysis of molybdenum - Part 15: Determination of sodium content - Flame atomic absorption spectrometry".

Its scope clause reads: GB/T 4325 provisions of this part of the molybdenum powder, molybdenum, molybdenum trioxide, ammonium molybdate and determination of sodium content.

This section applies to molybdenum powder, molybdenum, molybdenum trioxide and ammonium molybdate Determination of sodium content. Measurement range. 0.0003% to 0.080%. Its clauses include method summary; reagents; instrument; sample.

Found what you need?

Document preview — GB/T 4325.15-2013

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 63
Replacing
GB/T 4325.17-1984

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument
  • 5 Sample

1 Scope

GB/T 4325 provisions of this part of the molybdenum powder, molybdenum, molybdenum trioxide, ammonium molybdate and determination of sodium content.

This section applies to molybdenum powder, molybdenum, molybdenum trioxide and ammonium molybdate Determination of sodium content. Measurement range. 0.0003% to 0.080%.

2 Method summary

Sample decomposition of hydrogen peroxide, cesium chloride as deionization agent, air - acetylene flame atomic absorption spectrometer, the wavelength 589.0nm

At measuring the absorbance of sodium in the matrix matching conditions, calculate the amount of sodium.

3 Reagents

Unless otherwise indicated, this part of the reagents used are in line with national standards or industry standards for gifted class pure reagents, the double-distilled water

Or equivalent purity.

3.1

Hydrogen peroxide (rho = 1.10g/mL).

3.2

cesium chloride solution (25g/L).

3.3 molybdenum substrate

the nature of the sample application is basically the same, the sodium content of not more than 0.0001%.

3.4

Sodium standard solution A. Weigh 0.2543g pre-calcined by 550 °C sodium chloride (wNaCl>=99.9%), placed in a quartz beaker,

Dissolved in water and transferred to 1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 100µg sodium.

3.5 Sodium standard solution B

Pipette 10.00mL sodium standard solution A (3.4), placed in 100mL volumetric flask, dilute to the mark with water, mix uniform. This solution 1mL containing 10µg sodium.

4 Instrument

Atomic absorption spectrometer, with a sodium hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Characteristic concentration. a solution in the measurement matrix consistent solution of sodium characteristic mass concentration of not more than 0.01µg/mL;

--- Precision. measure up to 10 times the standard solution, the absorbance of the standard deviation should not exceed the average absorbance of 1.0%; the lowest

Concentration of standard solution (not "zero concentration" standard solution) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum concentration standard

The average absorbance of standard solution of 0.5%;

--- Linear curve. the curve according to concentration, is divided into five sections, the difference between the absorbance of the absorbance difference between the highest and the lowest segment of the segment

Ratio of not less than 0.7.

5 Sample

Molybdenum should smash through the 0.75mm standard sieve.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 4325.15

EditionTitleRevisionStatus
GB/T 4325.15-2013Methods for chemical analysis of molybdenum - Part 15: Determination of sodium content - Flame atomic absorption spectrometrycurrent editionCurrent
GB/T 4325.17-1984Methods for chemical analysis of molybdenum - Part 15: Determination of sodium content - Flame atomic absorption spectrometryprevious editionSuperseded

This page sells the current edition, GB/T 4325.15-2013. Earlier editions are listed for reference only.

How to Download GB/T 4325.15-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 4325.15-2013

$105.00