GB/T 42704-2023Textile trim materials in automotive interior applications - Determination of the emissions of volatile organic compounds - Chamber method (English PDF)
汽车内饰用纺织材料 挥发性有机物的测定 箱体法
Open the GB/T 42704-2023 preview as PDF
This is a limited preview
Buy now to download the full PDF (17 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 23, 2023
Implementation date
December 1, 2023
Scope
GB/T 42704-2023 is the English-translated version of 汽车内饰用纺织材料 挥发性有机物的测定 箱体法.
GB/T 42704-2023 measures what the textiles inside a car give off. A vehicle interior is a small, sealed, sun-heated volume lined with materials that continue to release volatile organic compounds long after manufacture — from the polymers themselves, from adhesives, backings and finishes — and the occupants breathe the result. Textile trim is a large share of the exposed surface, which makes it a large share of the emission. Measuring it credibly is the difficulty: emission rates depend strongly on temperature, air exchange and the ratio of sample area to chamber volume, so a number without a specified method means nothing and two suppliers' figures cannot be compared. This document describes a chamber method for collecting and determining the emissions of volatile organic compounds from textile trim materials used in automotive interiors. It applies to all types of automotive interior textile trim materials, including woven fabrics and the other constructions used in the application. Under ICS 59.080.30 and CCS W04, it is written for textile and trim suppliers, for the vehicle manufacturers writing interior air quality requirements into their specifications, and for the testing laboratories that have to produce comparable numbers.
Document preview — GB/T 42704-2023
National Standard of the People's Republic of China
- ICS
- 59.080.30
- Classification
- W04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions4
- 4 Principle6
- 5 Instruments and materials6
- 6 Sample preparation and sample handling9
- 7 Preparation before the test10
- 8 Sampling process11
- 9 Analytical test12
- 10 Test report14
- Appendix A (Informative) Sample information of benzene series and aldehydes and ketones16
- References17
Foreword
This document was issued on 23 May 2023 by the State Administration for Market Regulation; Standardization Administration of the PRC and takes effect on 1 December 2023.
It is a GB/T standard: recommended rather than compulsory, but it is the text a Chinese reviewer applies when assessing a submission.
1 Scope
GB/T 42704-2023 measures what the textiles inside a car give off. A vehicle interior is a small, sealed, sun-heated volume lined with materials that continue to release volatile organic compounds long after manufacture — from the polymers themselves, from adhesives, backings and finishes — and the occupants breathe the result. Textile trim is a large share of the exposed surface, which makes it a large share of the emission. Measuring it credibly is the difficulty: emission rates depend strongly on temperature, air exchange and the ratio of sample area to chamber volume, so a number without a specified method means nothing and two suppliers' figures cannot be compared. This document describes a chamber method for collecting and determining the emissions of volatile organic compounds from textile trim materials used in automotive interiors. It applies to all types of automotive interior textile trim materials, including woven fabrics and the other constructions used in the application. Under ICS 59.080.30 and CCS W04, it is written for textile and trim suppliers, for the vehicle manufacturers writing interior air quality requirements into their specifications, and for the testing laboratories that have to produce comparable numbers.
This document describes a test method for the collection and determination of the
emissions of volatile organic compounds from textile trim materials in automotive
interior applications using the chamber method.
This document applies to all types of textile trim materials in automotive interior
applications, including woven fabrics, knitted fabrics, non-woven fabrics and coated
fabrics, as well as composite fabrics.
2 Normative references
The following documents are referred to in the text in such a way that some or all of
their content constitutes requirements of this document. For dated references, only the
version corresponding to that date is applicable to this document; for undated references,
the latest version (including all amendments) is applicable to this document.
HJ/T 400-2007, Determination of volatile organic compounds and carbonyl
compounds in cabin of vehicles
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
total volatile organic compounds; TVOC
Volatile organic compounds with retention time between n-hexane and n-hexadecane
when using a Tenax tube for sampling, and a non-polar chromatographic column
(polarity index less than 10) for analysis.
3.2
total hydrocarbon mass concentration
Glass or stainless-steel adsorption tube, which is filled with solid adsorption material
with a particle size of 250 um ~ 180 um (60 mesh ~ 80 mesh).
Note: In most cases, Tenax-TA tubes are used, and adsorption tubes with other fillers
can also be used.
3.10
DNPH tube
A sampling tube that is filled with 2,4-dinitrophenylhydrazine (DNPH) silica gel.
4 Principle
Put the sample into the test chamber; heat it under the specified temperature, humidity
and air change rate; monitor the sampling environment in real time through the online
hydrogen flame ionization detector (FID); use the sampling tube to collect the air in the
chamber after a certain period of time; use gas chromatography/mass spectrometry
(GC-MS) and high performance liquid chromatography (HPLC) to qualitatively and
quantitatively determine the collected benzene series and aldehydes and ketones (see
5 Instruments and materials
5.1 Test chamber
5.1.1 General
5.1.1.1 The chamber capacity of the test chamber shall be 0.05 m3 ~ 4.0 m3, and a test
chamber with a capacity of (1.00+/-0.05) m3 is recommended. The interior of the
chamber shall be composed of a gas mixing device, a temperature regulating device, a
humidity regulating device, a bracket for placing test samples, air intake and exhaust
pipes, etc.
5.1.1.2 Chamber material: The inner wall of the chamber and the bracket for placing
test samples shall be made of electropolished stainless steel. If the necessary parts or
facilities inside the chamber cannot be made of electropolished stainless steel due to
technical reasons, they shall be made of materials that have a weak adsorption of
organic matter and do not emit organic matter, and the surface area of the parts or
facilities using these materials shall not exceed 5% of the total internal surface area of
the chamber.
5.1.1.3 Tightness: In order to avoid unnecessary air exchange, the chamber shall have
good airtightness.
5.1.1.4 Gas mixing: A gas mixing device shall be equipped, so that the airflow speed in
the center of the chamber in the empty chamber state is greater than 0.1 m/s during the
test process.
5.1.1.5 Chamber cleaning: By adopting appropriate cleaning methods, such as high-
temperature thermal desorption, etc., ensure that the chamber is thoroughly cleaned
after each test is completed. Before the start of the next test, all surfaces in the test
chamber that are in contact with volatile organic compounds shall also be cleaned to
ensure that the background value of the chamber will not affect the test results.
5.1.2 Temperature regulating device
The temperature regulating device shall ensure that the temperature difference at each
point in the space of the test chamber does not exceed +/-1 °C.
5.1.3 Humidity regulating device
The humidity regulating device shall ensure that the relative humidity of the gas
entering the test chamber is 45% +/- 5% at 23 °C and 5% +/- 0.5% at 65 °C, and no steam
or spray can be generated during the humidity regulating process.
5.1.4 Test chamber tightness
In order to avoid uncontrollable gas exchange, it shall be ensured that under the
condition of positive pressure of 1 000 Pa, the gas leakage per minute is less than 0.5%
of the volume of the test chamber. In order to prevent outside gas from entering the test
chamber, especially during gas sampling, it shall be ensured that the pressure of the test
chamber is slightly higher than atmospheric pressure, that is, it is operated under the
condition of slight positive pressure.
Set the chamber temperature to 65 °C, and test the airtightness of the test chamber by
applying a positive pressure of 1 000 Pa on its surface and recording the pressure change
of the test chamber within 2 h. The pressure sensor used shall be able to detect the
pressure below 100 Pa and the deviation shall not exceed +/-5%. During the 2 h test
period, the average leakage rate shall be calculated according to Formula (1):
Where:
nL - the average leakage rate of the volume of the test space, in permillage per minute
( per mille/min);
P1 - the absolute pressure of the chamber at the beginning of the tightness test, in
Pascals (Pa);
Before each sampling, use the gas flow calibrator (5.5) to calibrate the sampling flow
of the sampling system under the sampling load conditions.
5.5 Gas flow calibrator
Used to calibrate the sampling speed of the sampling pump. The maximum allowable
error of the flowmeter does not exceed +/-1%. When calibrating the flow rate, the error
of flow rates before and after shall be less than 5%.
6 Sample preparation and sample handling
6.1 Sample preparation
6.1.1 The to-be-tested samples shall be sealed and packaged in the pollution-free
polyethylene film or aluminum foil within the specified time (negotiated and recorded
by both the supplier and the buyer) after production is off-line, and put into the packing
box. Since volatile organic compounds are greatly affected by the environment, it is
advisable to make a complete record of the history of the samples before packaging
(such as storage environment temperature and humidity conditions, storage time).
6.1.2 During the transportation of samples, it is advisable to avoid direct exposure to
strong light or high temperature environment to avoid damage to the packaging. After
receiving the samples in the laboratory, they shall be stored in an environment with a
temperature not exceeding 23 °C in a well-packaged state.
6.2 Sample handling
6.2.1 Before the test starts, the sample needs to be pre-treated for 24 hours under the
condition of 23 °C +/- 2 °C. During the pre-treatment process, it is required by the
relevant party whether to open the package. If there is no requirement, the default is
that the sample package is intact. The samples shall be placed on the shelf or grid; the
samples shall neither contact with each other nor other objects outside the grid.
Requirements for the pollution concentration value of the environment before sample
pretreatment: toluene mass concentration <=20 ug/m3, formaldehyde mass concentration
<= 20 ug/m3.
6.2.2 The test sample shall be representative; the sample size shall be according to the
procedure specified in the product standard or the agreement between the two parties;
an appropriate product loading factor shall be provided. The requirements for test
material shall be negotiated between the supplier and the buyer. If there is no special
requirement, the recommended product loading factor is 2 m2/m3, that is, in the standard
test chamber, the exposed area of the sample is 2 m2, and multiple samples can be
combined and the samples cannot be stacked. Weigh the sample mass and record,
accurate to 1 g.
7 Preparation before the test
7.1 Test chamber cleaning
7.1.1 Chamber cleaning.
First, mechanical cleaning methods (such as industrial vacuum cleaners) shall be used
to remove residual particles and impurities from the previous test, and then high-
temperature cleaning shall be used for aging of the chamber or alkaline detergent shall
be used to clean the chamber. When using heated purge air to clean the test chamber at
high temperature, it shall be ensured that the temperature of all inner surfaces in contact
with the atmosphere in the test chamber exceeds 200 °C, and the air shall be changed
and cleaned repeatedly for 10 times after reaching the heating temperature. If alkaline
detergent is used, use deionized water to rinse the entire chamber twice, followed by a
hot wash with clean air at the test temperature. Monitor the background concentration
of the chamber according to the requirements of 7.2. If the background concentration
does not meet the requirements, continue to clean the chamber until the background
concentration of the chamber reaches the requirements of 7.2.
7.1.2 Cleaning of other accessories
7.1.2.1 For the components that come into contact with the gas in the test chamber but
cannot be directly cleaned during the cleaning process in 7.1.1, technically equivalent
cleaning measures shall be taken separately.
7.1.2.2 For other components (such as sealing rings) whose temperature resistance is
lower than 180 °C in the chamber, generally use deionized water to clean, and dry at
120 °C for 2 h ~ 3 h to achieve the cleaning effect.
7.2 Chamber background concentration monitoring
Under the condition of 65 °C, collect the background gas samples, and respectively
determine the content of the target pollutants in the background gas samples. The sum
of the mass concentration of total volatile organic compounds shall be less than 50
ug/m3, and the mass concentration of each volatile organic compound shall be less than
5 ug/m3. The total hydrocarbon mass concentration monitored by online FID shall be
less than 1 600 ug/m3.
7.3 Handling of connected gas-guide tubes
Treat at (100+/-5) °C for about 12 hours.
7.4 Handling of Tenax tubes
Before use, the Tenax tube needs to undergo high-temperature aging in an aging furnace.
The aging conditions are as follows: the temperature is 300 °C, the nitrogen flow rate
is 100 mL/min, the aging time of the new Tenax tube is 18 h, and the aging time of the
the recommended sampling flow rate is 100 mL/min, and the sampling time is 30 min;
for the DNPH tube, the sampling flow rate is 400 mL/min, and the sampling time is 30
min.
Note: For Tenax tubes, it is generally recommended that the maximum sampling
volume be <=5 L.
Connect the gas-guide tube connected with the sampling tube to the outlet of the test
chamber or other sampling ports of the discharge test chamber; pay attention to and
record the time and temperature of connecting the sampling tube; record the
atmospheric pressure if necessary. At the end of sampling, disconnect the gas-guide
tube from the sampling port of the test chamber; note and record the time of
disconnection; re-determine the sampling flow; turn off the pump. Disconnect the
connection between the sampling tube and the gas-guide tube; use a screw cap fitting
with a PTFE collar to seal both ends; write the number on it; wrap it in aluminum foil;
send it to the instrument for analysis as soon as possible; analyze the samples in the
Tenax tube and DNPH tube according to Appendix B and Appendix C in HJ/T 400-
2007 respectively. If immediate analysis is not available, store it in a refrigerator at
(4+/-2) °C, for a storage period up to 7 days.
8.6 During the entire test process, the temperature and humidity of the test chamber and
the total hydrocarbon mass concentration rhox monitored by the online FID shall be
recorded.
8.7 After the test, the test chamber shall be cleaned immediately according to 7.1.
Remaining clauses in the full document
- 8 Sampling process
- 9 Analytical test
- 10 Test report
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
HJ/T 400-2007, Determination of volatile organic compounds and carbonyl
Similar standards
How to Buy GB/T 42704-2023
- 1Add to cart. Click the "Buy GB/T 42704-2023" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards