GB/T 42623-2023Planning and selection of passenger lifts to be installed in office, hotel and residential buildings (English PDF)
安装于办公、旅馆和住宅建筑的乘客电梯的配置和选择
This is a limited preview
Buy now to download the full PDF (44 pages)
Need quotation for your management?
Get a formal quotation for GB/T 42623-2023 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
May 23, 2023
Implementation date
May 23, 2023
Scope
GB/T 42623-2023 is the English-translated version of 安装于办公、旅馆和住宅建筑的乘客电梯的配置和选择.
This document gives the requirements and recommendations for traffic planning and the selection of newly installed passenger lifts in office, hotel and residential buildings, for lift configurations both simple and complex.
It guides the choice of the most appropriate traffic planning method and helps determine how many lifts are needed, how they are configured and what their main parameters should be, setting out the design criteria used in the assessment.
The document applies to the lift categories listed in its Table 1, based on GB/T 7025.1-2023: Class I lifts designed to carry passengers, Class II lifts designed mainly for passengers but also able to carry goods, and Class VI lifts designed for heavy traffic and frequent use.
A building of mixed use is covered where it can be assessed separately as an office, a hotel or a residential building. The document presents one standardised approach; other methods may also be valid but are not covered here.
Found what you need?
Document preview — GB/T 42623-2023
National Standard of the People's Republic of China
- ICS
- 91.140.90
- Classification
- Q 78
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 symbols
- 5 applications
- 5.1 General
- 5.2 Design process
- 5.3 Selection of analytical methods
- 5.4 Selection of Design Criteria
- 5.5 Initial elevator configuration
- 6 Basis, derivation and assumed data
- 6.1 Basis and derived data for computational and simulation methods
- 6.2 Building data
- 6.3 Determining the number of people
- 6.4 Passenger data
- 6.5 Elevator Data
- 7 Calculations
- 7.1 Uplink peak formula
- 7.2 Elevator Selection Chart
- 8 Simulation method
- 8.1 General
- 8.2 Series Simulation
- 8.3 Requirements for Simulation
- 8.4 Evaluation and review of simulation results
- 9 report
- 9.1 General
- 9.2 Compilation of information
- 9.3 Building related information
- 9.4 Design criteria
- 9.5 Data related to elevator configuration
- 9.6 Elevator performance output data of algorithm
- 9.7 Output data of the simulation method
- Appendix A (informative) Selection of rated load capacity and effective area of the car
- Appendix B (Informative) Design Flowchart
- Appendix C (Informative) Elevator Selection Chart
- Appendix D (Informative) Calculations and Reporting Examples
- Appendix E (informative) Simulation method and report example
- Appendix F (Informative) Building Data Sheet
- Appendix G (Informative) Selection of Rated Speed
- Reference
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents" drafting.
This document is modified to adopt ISO 8100-32:2020 "Elevators for carrying people and goods - Part 32. Installation in offices, hotels and residences Configuration and Selection of Passenger Elevators for Buildings.
Compared with ISO 8100-32:2020, this document has made the following structural adjustments.
--- Added the clause numbers of the introduction, 5.1, 5.3, 5.4.3, 5.5, 6.1 and 6.2;
--- D 7 in Appendix D corresponds to the "example report" of D 6 in Appendix D of ISO 8100-32:2020;
---Change the suspended paragraph in Appendix E to E 1, and extend the number of subsequent clauses; E 6 corresponds to ISO 8100-32:2020 Appendix E E 4 "Example Report".
The technical differences between this document and ISO 8100-32:2020 and their reasons are as follows:
---Deleted special measures for people with disabilities to extend walking time [see 6.5.1d) in ISO 8100-32:2020], so that Harmonized with 1.4h);
--- ISO 8100-30:2019 (see Chapter 3) is replaced by GB/T 7025.1-2023 with normative references, between the two documents The degree of consistency is modified to suit my country's national conditions and improve operability;
--- Increased content of loading rate [(see 9.7d)], because this parameter is essential. The following editorial changes have been made to this document.
---Change the name of the standard to "Configuration and Selection of Passenger Elevators Installed in Office, Hotel and Residential Buildings";
---Delete the contents of "elevators with a rated speed of 2.5m/s and higher" and "bicycles that passengers may carry" (see Chapter 1 of ISO 8100-32:2020);
--- Deleted the informative reference to ISO 4190-5:2006 (see 3.3 of ISO 8100-32:2020);
---Deleted "different regions have different regulations on average weight" when selecting the rated load, and the selection of the effective area of the car At the same time, the content of "the per capita area depends on the relevant national norms" (see 6.5.3 of ISO 8100-32:2020);
---Delete the description of "tperf is the execution time of a single floor (s)" and "N is the number of service floors above the entrance floor" (see ISO 8100-32.
7.1 of 2020);
--- Deleted the content of "Other values can be selected according to national specifications" in Appendix C (informative) (see ISO 8100-32:2020 C 2).
Introduction
0.1 Elevator configuration refers to the description of a group of elevators by the number of elevators, number of passengers, floors served, rated speed, and various other parameters. combine Reasonable elevator configuration can usually provide good service to passengers at low cost in constructing building core space.
The elevator industry has previously relied on probability-based up-peak formulas to calculate run times and capacity. If an elevator is configured The configuration is considered acceptable if the run interval and delivery capacity meet the recommended design criteria. This traditional upside peak analysis It is still valid for relay-controlled elevators, and can also be used for evaluation of simple situations or preliminary estimation of more complex situations.
Some elevators today employ sophisticated traffic control systems based on computer programs. These control systems are difficult to describe by formula However, computer simulation programs can be used for evaluation.
0.2 This document provides the following two methods for determining the appropriate elevator configuration.
a) Calculation method. adopt the traditional upward peak formula. The selection diagrams in Appendix C are based on calculation methods, which provide A quick way to determine elevator configuration for simple cases. The run interval and conveying capacity determined by this method can be used to evaluate the elevator configuration. It is recommended to use this method in simpler cases, or to initially determine the elevator configuration for further simulation. analysis. The method is given in Chapter 7, and Appendix D gives a typical example of the use of the formula.
b) Simulation method. used to determine the service level of different traffic control systems (such as destination layer control). In complex situations or where it is necessary to obtain Use this method when you need more information than run intervals and upstream peak capacity. Chapter 8 gives the Methods, typical examples are given in Appendix E.
Both methods require building, passenger and elevator data, see Chapter 6. See Appendix F for its initial data sheet.
0.3 This document adopts the suggestion of ISO /T R11071-2. "Although the number of passengers and the load have always been regarded as the same parameter in safety regulations However, when writing safety specifications in the future, it may be more meaningful if the load and the number of passengers can be treated differently. more passengers When refers to the traffic conveying capacity, while the load refers to the maximum carrying capacity of the elevator that is directly related to safety. " Therefore, this document distinguishes between the number of passengers and the load when selecting the rated load capacity and the effective area of the car (see 6.5.3 and Appendix A).
0.4 This document is intended to provide reference for the initial stage of construction projects, especially for elevator customers or building owners, architectural designers, engineering consultants Consultants, building managers, elevator consultants, elevator contractors, building developers, general contractors and other interested parties.
0.5 This document takes into account some special needs, such as the accessibility of persons with disabilities (see 6.5.1).
1 Scope
1.1 This document applies to the traffic planning and selection of newly installed passenger elevators in office, hotel and residential buildings. The requirements and suggestions given Suitable for both simple and complex elevator configurations.
This document provides guidance for selecting the most appropriate transport planning method, where applicable.
This document helps to determine the number of elevators and configuration and its main parameters.
1.2 This document applies to the elevator types in Table 1.
Table 1 Elevator Types Based on GB/T 7025.1-2023
Category use
Class I elevators designed for transporting passengers
Class II is mainly designed for the transportation of passengers, but also for the transportation of goods.
Class VI Elevators specially designed to adapt to large traffic flow and frequent use
This document also applies if buildings with mixed uses can be assessed separately as office, hotel or residential buildings. This document presents a standardized approach to elevator traffic planning. Other alternative methods may also be effective, but these are not covered in this document.
1.3 This document gives the basic requirements and suggestions on the configuration and selection of elevators, involving:
a) the design criteria used for the assessment;
b) design criteria parameters;
c) calculation method (see Chapter 7) for simple elevator configuration and selection (see 5.3);
d) simulation methods (see Chapter 8) for simple and more complex elevator configuration and selection (see 5.3);
e) the report format of the lift configuration and selection analysis results provided to interested parties;
f) take into account existing safety regulations for determining the number of passengers for a particular car area;
g) Consider space for luggage, strollers, etc., and other non-personal items that elevator passengers may carry;
h) Accessibility for persons with disabilities.
1.4 This document does not cover the following:
a) freight elevators only;
b) Passenger elevators with multiple cars in the same shaft;
c) Double-deck passenger elevators;
d) Elevators with a lifting height exceeding 200m and (or) a rated speed greater than 7m/s;
e) Changes in the calculation method (for example. different from the traffic situation of the up peak, the door opening time, the height of each floor is not uniform, the height of each floor The number of people is not uniform, and the rated speed cannot be reached when running on a single floor, etc.);
f) variations of simulation methods (e.g. traffic models with different passenger demand);
g) design of simulation models or traffic control systems;
h) high-level characteristic parameters of passengers (eg. walking speed);
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 44 pages — is available in the English PDF.
How to Download GB/T 42623-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 42623-2023
$590.00