GB/T 41868-2022Modbus TCP security protocol specification (English PDF)
Modbus TCP安全协议规范
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for GB/T 41868-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 14, 2022
Implementation date
May 1, 2023
Scope
GB/T 41868-2022 is the English-translated version of Modbus TCP安全协议规范.
GB/T 41868-2022 is the Chinese national specification for carrying Modbus TCP over TLS, and clause 1 says it sets out the service definition, the protocol description, the system dependencies and the TLS requirements.
Its contents list covers normative statements, an overview of mbap, mbaps and transport layer security, the TLS handshake, cipher suite selection, mbaps role-based client authorization, and TLS version, fragmentation, compression and session renegotiation, with a normative Annex A on the mbaps packet structure.
Its introduction states that Modbus TCP security keeps the same ADU as Modbus TCP, uses the IANA-registered port 802, allows only TLS 1.2 and above, and relies on X.509v3 certificates with two-way authentication plus an OID extension through which device makers declare the role and authority of a client.
Clause 1 adds that the document is intended for organizations developing or testing Modbus products. Issued on 14 October 2022, it has applied since 1 May 2023.
Found what you need?
Document preview — GB/T 41868-2022
National Standard of the People's Republic of China
- ICS
- 25.040
- Classification
- N 10
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Abbreviations
- 5 Normative Statements
- 6 Overview
- 6.1 mbap overview
- 6.2 Overview of mbaps
- 6.3 Overview of Transport Layer Security
- 7 Service Definition
- 8 Protocol Specification
- 8.1 TLS Protocol
- 8.2 TLS handshake
- 8.3 Cipher Suite Selection
- 8.4 mbaps role-based client authorization
- 9 System dependencies
- 10 TLS requirements
- 10.1 TLS version
- 10.2 TLSv1.2 Cipher Selection
- 10.3 TLS Fragmentation
- 10.4 TLS compression
- 10.5 TLS session renegotiation
- Appendix A (normative) mbaps packet structure
- Reference
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.
Introduction
The national standards for the Modbus protocol that have been published so far include.
GB/T 19582.1-2008 "Industrial Automation Network Specification Based on Modbus Protocol Part 1: Modbus Application Protocol";
GB/T 19582.2-2008 "Industrial Automation Network Specification Based on Modbus Protocol Part 2: Modbus Protocol in Serial Implementation Guide on Links;
GB/T 19582.3-2008 "Industrial Automation Network Specification Based on Modbus Protocol Part 3: Modbus Protocol in Implementation Guide on TCP/IP";
GB/T 25919.1-2010 "Modbus Test Specification Part 1: Modbus Serial Link Conformance Test Specification";
GB/T 25919.2-2010 "Modbus Test Specification Part 2: Modbus Serial Link Interoperability Test Specification".
The Modbus protocol was originally used in 1979 as a serial protocol for communication between industrial controllers and computers or other upper computers. year.1996, The Modbus protocol has been extended to Ethernet, using port 502 registered by IANA, supporting ModbusTCP Ethernet-based protocol. At the same time, ModbusTCP maintains the consistency and compatibility with the ModbusRTU serial protocol, which makes Modbus serial devices Bridging communication via ModbusTCP is very easy. In 2002, Modbus abstracted the Modbus application layer, began to use the concept of ModbusPDU, released the Modbus application layer specification, for different serial and TCP ADU, also published specifications for serial and Ethernet. At the same time, Modbus also joined IEC 61784 as one of the profiles.
Based on the conversion of the Modbus protocol specification in IEC 61784, my country has released the GB/T 19582 Modbus series of recommended countries standard.
It is also due to the publication of national standards, which makes it possible to conduct interoperability testing in accordance with normative standards. It was later published
GB/T 25919 series of standards, which greatly improves the consistency and interoperability of a large number of Modbus applications, which is beneficial to industrial automation systems. system development and integration.
Like all industrial communication protocols, Modbus was originally designed without information security features. With industrial communication and applications for data The demand for confidentiality and integrity, device identification, etc. has increased. This document uses the common TLS transport layer encryption technology to support Modbus The protocol has been extended to enable encrypted Modbus communications to increase resistance to common attacks such as replay and man-in-the-middle.
ModbusTCP security maintains the same ADU as ModbusTCP, which enables easy ModbusTCP communication to migrate to ModbusSecurity. ModbusTCP security uses the IANA registered port 802 for secure communication. Mod-bussecurity only allows TLS1.2 and above.
ModbusTCP security also uses the X.509v3 digital signature certificate, which is used when the client and the server conduct the TLS negotiation handshake.
Use two-way authentication. At the same time, the OID extension is used in the certificate, and device manufacturers can use this extension to specify the role and authority of the client, User identification and role-based control required for industrial information security can be realized. With the introduction of the ModbusTCP security standard, There are a large number of devices using Modbus, which provides a concise and direct upgrade path. ModbusTCP Security Protocol Specification
1 Scope
This document specifies the service definition, protocol description, system dependencies, and TLS requirements of the ModbusTCP security protocol.
This document is intended for organizations developing or testing Modbus products.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.
RFC5280 Internet X.509 Public Key Infrastructure Certificate and Certificate Revocation List (CRL) Profile [Internetx.509
3 Terms and Definitions
There are no terms and definitions that need to be defined in this document.
4 Abbreviations
The following abbreviations apply to this document. AuthZ. Authorization BER. Basic Encoding Rules (BasicEncodingRules)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Normative references
RFC 5280
Similar standards
How to Download GB/T 41868-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.