GB/T 41759-2022Technical specification of corrosion inhibitor for grounding grid resistance-reducing material (English PDF)
接地网降阻材料用缓蚀剂技术规范
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 41759-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 14, 2022
Implementation date
May 1, 2023
Scope
GB/T 41759-2022 is the English-translated version of 接地网降阻材料用缓蚀剂技术规范.
GB/T 41759-2022 is the technical specification for the corrosion inhibitors mixed into inorganic resistance-reducing materials for grounding grids.
It specifies the technical requirements, the inspection methods and rules, and the marking, packaging and storage, and applies to the resistance-reducing materials of steel grounding grids in industrial and civil power installations; for pure copper or copper-plated steel grids the conditions are for reference.
The document states that the corrosion inhibitor added to the resistance-reducing material should not exceed 5 %, and carries normative annexes on the determination of the corrosion inhibition efficiency, of the nominal resistivity, of the impulse and power frequency current tolerance and of stability.
It cites GB/T 16927.3-2010, GB/T 24196-2009 and DL/T 380-2010. Issued on 14 October 2022, it has applied since 1 May 2023.
Found what you need?
Document preview — GB/T 41759-2022
National Standard of the People's Republic of China
- ICS
- 25.220.99
- Classification
- A 29
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Technical requirements
- 5 Inspection methods and rules
- 6 Marking, packaging and storage
- Appendix A (Normative) Determination of Corrosion Inhibition Efficiency
- Appendix B (normative) Determination of Nominal Resistivity
- Appendix C (normative) Determination of impulse and power frequency current tolerance
- Appendix D (normative) Determination of stability
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.
1 Scope
This document specifies the technical requirements, inspection methods and rules, marking, packaging and storage of corrosion inhibitors for inorganic resistance reducing materials for grounding grids. Require.
This document applies to the resistance reduction materials of steel grounding grids for industrial and civil power installations. For pure copper (or copper-plated steel) grounding grid resistance reducing materials The technical conditions for using corrosion inhibitors are for reference.
Note: Corrosion inhibitor for grounding grid resistance-reducing material means that it can be used to inhibit and slow down the resistance-reducing material after being evenly mixed with the grounding grid resistance-reducing material on the steel used to make the grounding grid Corrosive substances such as metals.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.
GB/T 16927.3-2010 High Voltage Test Technology Part 3: Definition and Requirements of Field Test
GB/T 24196-2009 Electrochemical test methods for corrosion of metals and alloys - Guidelines for potentiostatic and potentiodynamic polarization measurements
DL/T 380-2010 Technical requirements for grounding resistance-reducing materials
3 Terms and Definitions
The terms and definitions defined in DL/T 380-2010 and the following terms and definitions apply to this document.
3.1 Grounding grid resistance-reducing material
Engineering materials used to reduce the grounding resistance of the grounding grid and lay (cast) around the grounding body in the grounding grid.
Note: Including resistance reducing agent, conductive cement and materials that constitute grounding units such as grounding modules.
3.2 Corrosion inhibitor
Existing in the corrosion system at an appropriate concentration does not significantly change the properties and concentration of the corrosion medium, and can significantly reduce the corrosion rate. substance.
3.3 Corrosion inhibition efficiency
Corrosion inhibitors reduce the relative extent to which the resistance-reducing material corrodes the steel grounding grid.
4 Technical requirements
4.1 General requirements
The amount of corrosion inhibitor added to the resistance reducing material of the grounding grid should not exceed 5%.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 16927.3-2010High voltage test techniques -- Part 3: Definitions and requirements for on-site testing
- GB/T 24196-2009Corrosion of metals and alloys -- Electrochemical test methods -- Guidelines for conducting potentiostatic and potentiodynamic polarization measurements
- DL/T 380-2010Technical condition of material for reduced ground resistance
Similar standards
How to Download GB/T 41759-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 380-2010 — Technical condition of material for reduced ground resistance
GB/T 16927.3-2010 — High voltage test techniques -- Part 3: Definitions and requirements for on-site testing
GB/T 24196-2009 — Corrosion of metals and alloys -- Electrochemical test methods -- Guidelines for conducting potentiostatic and potentiodynamic polarization measurements
GB/T 41759-2022