GB/T 41704-2022Test methods of cathode materials for lithium ion battery—Determination of magnetic impurities content and residual alkali content (English PDF)
锂离子电池正极材料检测方法 磁性异物含量和残余碱含量的测定
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 41704-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 14, 2022
Implementation date
February 1, 2023
Scope
GB/T 41704-2022 is the English-translated version of 锂离子电池正极材料检测方法 磁性异物含量和残余碱含量的测定.
GB/T 41704-2022 gives the methods for determining the magnetic impurities content and the residual alkali content of cathode materials for lithium ion batteries.
Magnetic impurities are enriched in a clean environment with a magnetic bar of at least 0.5 T, then measured by inductively coupled plasma atomic emission spectrometry; large particle magnetic impurities, at least 10 µm across, are counted under the scanning electron microscope after vacuum filtration.
Residual alkali is dissolved in water, filtered and titrated with 0.1 mol/L hydrochloric acid, and reported as the mass fractions of lithium carbonate, lithium hydroxide, residual alkali and residual lithium over the range 0.001 % to 2.500 %.
It cites GB/T 601, GB/T 6682 and GB/T 8170, and fixes the contents of the test report. It was issued on 14 October 2022 and has applied since 1 February 2023.
Found what you need?
Document preview — GB/T 41704-2022
National Standard of the People's Republic of China
- ICS
- 77.160
- Classification
- H 16
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- Introduction4
- 1 Scope5
- 2 Normative References5
- 3 Terms and Definitions5
- 4 Determination of Magnetic Impurities Content6
- 5 Determination of Residual Alkali Content13
- 6 Test Report17
1 Scope
This document specifies the determination method for magnetic impurities content and residual alkali content in the cathode materials for lithium ion battery.
This document is applicable to the determination of magnetic impurities content and residual alkali content in the cathode materials for lithium ion battery. The determination range of the magnetic impurities content is >= 1 µg/kg; the determination range of residual alkali content (mass fraction) is 0.001% ~ 2.500%.
2 Normative References
The contents of the following documents constitute indispensable clauses of this document through the normative references in this text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.
GB/T 601 Chemical Reagent - Preparations of Standard Volumetric Solutions
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
GB/T 8170 Rules of Rounding off for Numerical Values & Expression and Judgement of Limiting Values
3 Terms and Definitions
The following terms and definitions are applicable to this document.
3.1 Magnetic Impurities
Magnetic impurities refer to impurities in the cathode materials for lithium ion battery that can be adsorbed by the magnetic bar with a magnetic induction intensity of not less than 0.5 T (5,000 Gauss).
3.2 Large Particle Magnetic Impurities
Large particle magnetic impurities refer to magnetic impurities with a diameter of not less than 10 µm under the scanning electron microscope.
3.3 Residual Alkali
Residual alkali refers to alkaline substances attached to the surface of the particles of the cathode materials for lithium ion battery.
4 Determination of Magnetic Impurities Content
4.1 Inductively Coupled Plasma Atomic Emission Spectrometry
4.1.1 Principle
In a clean environment free of magnetic impurities, use a magnetic bar to adsorb and enrich the magnetic impurities in the cathode material.
4.1.2 Reagents or materials
Unless it is otherwise specified, all reagents used in this Method are of guaranteed purity and Grade-1 water specified in GB/T 6682.
4.1.2.1 Nitric acid (rho = 1.42 g/mL).
4.1.2.6 Zinc standard stock solution (100 µg/mL), prepared from high-purity metals or compounds, or adopt a certified single-element standard stock solution.
4.1.2.7 Lithium standard stock solution (100 µg/mL), prepared from high-purity metals or compounds, or adopt a certified single-element standard stock solution.
4.1.2.11 Lithium standard solution B: transfer-take 20.00 mL of lithium standard solution A (4.1.2.10); place it in a 100 mL volumetric flask. Add 3 mL of nitric acid (4.1.2.1); use water to dilute to the scale; mix it well and immediately transfer it to a dry plastic jar. 1 mL of this solution contains 2 µg of lithium.
4.1.3 Instruments and equipment
4.1.3.1 Environmental iron removing rod: magnetic induction intensity >= 0.5 T (5,000 Gauss), wrapped with plastic wrap.
4.1.3.2 Plastic jar: 500 mL.
4.1.4 Sample
The particle of the sample shall be not greater than 0.154 mm.
4.1.5 Test procedures
4.1.5.4.1 Put the test portion in a 500 mL plastic jar (4.1.3.2), add 300.0 g of water, tighten the lid (to prevent leakage); place it on the ball mill (4.1.3.5), adjust the rotating speed to 60 r/min ~ 100 r/min; after rolling and mixing for 30 min, remove it.
4.1.5.4.3 Transfer the magnetic bar (4.1.3.3) to a clean 200 mL beaker; add water, until the magnetic bar (4.1.3.3) is immersed; prevent the water from directly rushing to the surface of the magnetic bar (4.1.3.3).
4.1.5.4.4 There are two optional modes for dissolution.
4.1.5.4.5 Remove the beaker or colorimetric tube. After cooling, transfer all the solution to a 50 mL volumetric flask. Use a small amount of water to rinse the magnetic bar (4.1.3.3); repeat for 3 times. Then, transfer all the washing solution to a volumetric flask and use water to reach a constant volume; record the volume as V.
4.1.5.1 Iron removal before test
Before the test, use aqua regia (4.1.2.2) to clean the magnetic bar (4.1.3.3); use the environmental iron removing rod (4.1.3.1) to carry out meticulous iron removal treatment on all instruments and supplies used in the test.
4.1.5.5 Preparation of standard series solutions
4.2.5 Test procedures
4.2.5.2 Weigh-take 200.0 g of the sample, accurate to 0.1 g. Place the sample in a 500 mL plastic jar (4.2.3.3); add water to the shoulder of the jar; tighten the lid, then, use the sealing film to seal it. Manually mix the water and the sample, so that there is no precipitation at the bottom of the jar. Put the jar into the magnetic ring sleeve (4.2.3.2); use the heat sealing film to seal it. Place it on the ball mill (4.2.3.4); after mixing it for 30 min, remove it.
4.2.5.3 After removing it, with the magnetic ring sleeve (4.2.3.2), pour out the water and material in the plastic jar (4.2.3.3); use water to repeatedly rinse the wall of the jar for more than 5 times, so as to ensure that there is no precipitation of sample at the bottom of the jar.
4.2.5.4 After assembling the filter film (4.2.2.3) and vacuum filtration device (4.2.3.6), remove the magnetic ring sleeve (4.2.3.2); use water to rinse the wall of the plastic jar (4.2.3.3) for more than 3 times. Pour the washing solution into the vacuum filtration device (4.2.3.6); use water to rinse the wall of the suction and filtration cup for more than 3 times.
4.2.6 Processing of test data
Count the number of large particle magnetic impurities. Respectively count the number of iron and stainless steel (iron-chromium-nickel).
5 Determination of Residual Alkali Content
5.1 Principle
Use a certain volume of water to dissolve the residual alkali on the surface of the sample with a certain mass. After filtration, take the filtrate; use the standard titration solution of hydrochloric acid to perform titration.
5.2 Reagents or Materials
Unless it is otherwise specified, all reagents used in this Method are of guaranteed purity and Grade-1 water specified in GB/T 6682.
5.2.1 Standard titration solution of hydrochloric acid: 0.1 mol/L. Adopt a nationally recognized certified reference material within the validity period, or prepare it in accordance with the stipulations of GB/T 601.
5.2.2 Plastic wrap.
5.3 Instruments and Equipment
5.4 Sample
The particle of the sample shall be not greater than 0.154 mm.
5.5 Test Procedures
5.6 Processing of Test Data
5.6.1 The residual lithium carbonate content in the sample, in mass fraction wLi2CO3, shall be calculated in accordance with Formula (4).
5.6.2 The residual lithium hydroxide content in the sample, in mass fraction wLiOH, shall be calculated in accordance with Formula (5).
5.6.3 The residual alkali content in the sample, in mass fraction wra, shall be calculated in accordance with Formula (6).
5.6.4 The residual lithium content in the sample, in mass fraction wrl, shall be calculated in accordance with Formula (7).
5.6.5 The calculation results shall be expressed in three decimal places and rounded off in accordance with the stipulations of GB/T 8170.
5.7 Precision
5.7.1 Repeatability
In terms of the measured values of two independent test results obtained under repeatability conditions, within the range of average values provided in Table 2, the absolute difference between the two test results does not exceed the repeatability limit (r), and the circumstance of exceeding the repeatability limit (r) does not exceed 5%. The repeatability limit (r) is obtained through linear interpolation or extrapolation in accordance with the data in Table 2.
6 Test Report
The test report shall include the following aspects: […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 41704-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 601-2016 — Chemical Reagent - Preparations of Standard Volumetric Solutions
GB/T 6011-2005 — Test method for flammability characteristics of fiber-reinforced plastics-Incandescent rod method
GB/T 6011-2026 — Test method for the flammability characteristics of fibre reinforced plastics - Incandescent rod method
Secure payment via Stripe
Payments accepted
GB/T 41704-2022
$210.00