Scope
GB/T 41136-2021 (Resistance welding equipment - Transformers - Integrated transformer-rectifier units for welding guns operating at 1 000 Hz) is available as an English-translated PDF.
GB/T 41136-2021 — This document specifies additional requirements for single-phase inverter resistance welding transformers with built-in rectifiers for direct current welding in ISO 5826: This document applies to transformers mainly used for welding tongs with an operating frequency of 1000Hz and a rated input voltage of 500V or other electrical pressure value: If this document is not revised, the requirements of ISO 5826 also apply:
Document preview — GB/T 41136-2021
National Standard of the People's Republic of China
- Classification
- J 64
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Power supply of the transformer-rectifier unit
foreword
This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents"
drafted:
This document is identical to ISO 22829:2017 "1000Hz transformer with built-in rectifier for transformer-integrated welding guns for resistance welding equipment:
Press":
The Chinese documents that have a consistent correspondence with the international documents normatively cited in this document are as follows:
---GB/T 8366-2021 Mechanical and electrical requirements for resistance welding machines (ISO 669:2016, IDT)
--- GB/T 25301-2021 General technical conditions for resistance welding equipment transformers applicable to all transformers (ISO 5826:
2014, IDT)
---GB/T 5465:2-2008 Graphical symbols for electrical equipment - Part 2: Graphical symbols (IEC 60417DB:2007, IDT)
Please note that some content of this document may be patented: The issuing agency of this document assumes no responsibility for identifying patents:
1 Scope
This document specifies additional requirements for single-phase inverter resistance welding transformers with built-in rectifiers for direct current welding in ISO 5826:
This document applies to transformers mainly used for welding tongs with an operating frequency of 1000Hz and a rated input voltage of 500V or other electrical
pressure value:
If this document is not revised, the requirements of ISO 5826 also apply:
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, dated citations
documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to
this document:
ISO 669 Resistance welding Mechanical and electrical requirements for resistance welding equipment (Resistancewelding-Resistancewelding
equipment-Mechanicalandelectricalrequirements)
ISO 5826 Resistance welding equipment transformers General specifications applicable to all transformers (Resistanceweldingequip-
ment-Transformers-Generalspecificationsapplicabletoaltransformers)
ISO 17677-1 Resistance welding vocabulary part 1: Spot, projection and seam welding (Resistance welding-Vocabulary-
Part 1: Spot, projection and seamwelding)
IEC 60417:2002 Graphical symbols for equipment (Graphicalsymbolsforuseoneequipment)
3 Terms and Definitions
Terms and definitions defined in ISO 669, ISO 5826 and ISO 17677-1 and the following terms and definitions apply to this document:
3:1
DC output current outputDCcurrent
I2d
The effective value (RMS) of the DC current at the output of the transformer-rectifier unit:
3:2
working time ontime
ts
Time to apply current:
4 Power supply of the transformer-rectifier unit
The rated input voltage should be provided by the inverter, the inverter should provide a rated voltage with a frequency of 1000Hz, and its waveform should be adapted to the transformer
characteristics of the rectifier-rectifier unit:
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
ISO 669 · ISO 5826 · ISO 17677 · IEC 60417
How to Buy GB/T 41136-2021
- 1Add to cart. Click the "Buy GB/T 41136-2021" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 46830.2-2026 — Plastics - Liquid crystal polymer (LCP) moulding and extrusion materials - Part 2: Preparation of test specimens and determination of properties
GB/T 28593-2026 — Sand and dust weather warning levels
GB/T 19608.3-2026 — Classification of special environmental conditions - Part 3: Plateau
Secure payment via Stripe
Payments accepted
GB/T 41136-2021
$245.00