Valid

GB/T 40909-2021Textiles—Determination of methylcyclosiloxane residues (English PDF)

纺织品 甲基环硅氧烷残留量的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 40909-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 11, 2021

Implementation date

May 1, 2022

Scope

GB/T 40909-2021 is the English-translated version of 纺织品 甲基环硅氧烷残留量的测定.

GB/T 40909-2021 is a Chinese national method for measuring residues of three cyclic siloxanes in textiles: octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5) and dodecamethylcyclohexasiloxane (D6).

The residues are extracted from the textile sample with an organic solvent in an ultrasonic bath, the extract is purified and measured by gas chromatography-mass spectrometry, and the results are quantified with an internal standard.

The standard specifies the reagents, including the reference substances and the internal standard M4Q, the stock and working solutions, the instruments, the test procedure, the calculation of results, the quantitation limit and precision, and the test report.

An informative annex gives example chromatographic conditions. It applies to all types of textiles, was issued on 11 October 2021 and has applied since 1 May 2022.

Found what you need?

Document preview — GB/T 40909-2021

National Standard of the People's Republic of China

ICS
59.080.01
Classification
W 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions4
  • 4 Principle4
  • 5 Reagents or materials4
  • 6 Instruments and equipment5
  • 7 Test procedures6
  • 8 Result calculation and expression8
  • 9 Quantitation-limit and precision8
  • 10 Test report9
  • Appendix A (Informative) Gas chromatography-mass spectrometry analysis conditions10

1 Scope

This document describes the test methods for the determination of octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5) and dodecamethylcyclohexasiloxane (D6) residues in textiles by gas chromatograph-mass spectrometer (GC-MS).

This document applies to all types of textiles.

2 Normative references

There are no normative references in this document.

3 Terms and definitions

There are no terms and definitions that need to be defined in this document.

4 Principle

Use organic solvent to ultrasonically extract the residual methylcyclosiloxane in the textile sample; for the extract after purification, use the gas chromatograph-mass spectrometer for determination and the internal standard method for quantitation.

5 Reagents or materials

Unless otherwise specified, all the reagents shall, at least, be analytical reagents.

5.1 n-hexane: CAS No. 110-54-3.

5.2 Tetrahydrofuran: CAS No. 109-99-9.

5.3 Methylcyclosiloxane standard substance: see 5.3.1 ~ 5.3.3.

5.3.1 Octamethylcyclotetrasiloxane (D4): CAS No. 556-67-2, purity >=98.0%.

5.3.2 Decamethylcyclopentasiloxane (D5): CAS No. 541-02-6, purity >=98.0%.

5.3.3 Dodecamethylcyclohexasiloxane (D6): CAS No. 540-97-6, purity >=98.0%.

5.4 Tetramethylsiloxysilane (Trimethylsiloxysilane) (M4Q): CAS No. 3555-47-3, purity >=98.0%, internal standard (IS).

5.5 Standard stock solution: Use a balance (6.1) to weigh a certain amount of standard substance (5.3); use n-hexane (5.1) to dissolve it and fix volume, to prepare a single-component or mixed standard stock solution of a concentration of 1 000 mg/L.

Note: The standard stock solution, which is stored in a refrigerator at 0 °C ~ 4 °C, is valid for 6 months.

5.6 Internal standard stock solution: Use the balance (6.1) to accurately weigh the internal standard substance (5.4); use n-hexane (5.1) to dissolve it and fix volume, to prepare an internal standard stock solution of a concentration of 500 mg/L.

Note: The internal standard stock solution, which is stored in a refrigerator at 0 °C ~ 4 °C, is valid for 6 months.

5.7 Mixed standard working solution: Accurately draw an appropriate amount of standard stock solution (5.5) and internal standard stock solution (5.6); use n-hexane (5.1) to prepare a 10.0 mg/L mixed standard working solution. The concentration of internal standard in the mixed standard working solution is 5.0 mg/L. This solution is prepared for immediate use. Other appropriate concentrations can also be used as required.

5.8 Internal standard working solution.

5.8.1 n-hexane internal standard working solution: Use n-hexane (5.1) and internal standard stock solution (5.6) to prepare a n-hexane internal standard working solution of a concentration of 5.0 mg/L. This solution is prepared for immediate use. Other appropriate concentrations can also be used as required.

5.8.2 Tetrahydrofuran internal standard working solution: Use tetrahydrofuran (5.2) and internal standard stock solution (5.6) to prepare a tetrahydrofuran internal standard working solution of a concentration of 5.0 mg/L. This solution is prepared for immediate use. Other appropriate concentrations can also be used as required.

6 Instruments and equipment

6.1 Balance: the division value is 0.1 mg.

6.2 Extraction bottle: 40 mL ~ 60 mL, made of hard glass, equipped with a screw cap.

Appendix A (Informative) Gas chromatography-mass spectrometry analysis conditions

A.1 Gas chromatograph-mass spectrometer parameters

Since the test results depend on the instrument used, it is impossible to give general parameters for instrumental analysis. The following parameters have been shown to be suitable for testing:

a) Chromatographic column: TG-5SilMS, 30.0 m × 0.25 mm × 0.25 µm, or equivalent;

b) Column temperature: maintain the initial column temperature at 30 °C for 3 min; rise the temperature to 150 °C at 40 °C/min; rise to 300 °C at 60 °C/min; maintain for 5 min;

c) Injection volume: 1 µL;

d) Inlet septum: Merlin micro-seal septum;

e) Injection port temperature: 200 °C;

f) Temperature of chromatography mass spectrometry interface: 280 °C;

g) Ion source temperature: 250 °C;

h) Carrier gas: helium; purity >=99.999%; flow rate: 1.0 mL/min;

i) Injection method: splitless injection;

j) Ionization mode: EI;

k) Ionization energy: 70 eV;

l) Solvent delay: 5 min;

m) Mass spectrometry scanning mode: For qualitative analysis, adopt full scan mode (SCAN), with the scanning mass (m/z) of 50~450; for quantitative analysis, adopt selected monitoring ion mode (SIM), where the selected monitoring ions are shown in Table A.1. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 40909-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40909-2021

$165.00