Valid

GB/T 40820-2021Residual direct current detecting device (RDC-DD) to be used for mode 3 charging of electric vehicles (English PDF)

Also coversGBT40820-2021

Open the GB/T 40820-2021 preview as PDF

Preview — first pages of GB/T 40820-2021

This is a limited preview

Buy now to download the full PDF

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 11, 2021

Implementation date

May 1, 2022

Scope

GB/T 40820-2021 (Residual direct current detecting device (RDC-DD) to be used for mode 3 charging of electric vehicles) is available as an English-translated PDF.

GB/T 40820-2021 — This Document specifies the classification, characteristics, marking, conditions of use and installation, technical requirements for structure and operation, and corresponding tests of residual direct current detecting device (RDC-DD) to be used for Mode 3 charging of electric vehicles.

Document preview — GB/T 40820-2021

National Standard of the People's Republic of China

Issued by: SAMR; SAC

Contents

  • Foreword...4
  • 1 Scope...6
  • 2 Normative References...7
  • 3 Terms, Definitions and Symbols...8
  • 4 Classification of RDC-DD (RDC-MD, RDC-PD)...9
  • 5 Characteristics of RDC-DDs...12
  • 6 Marking and Other Product Information...17
  • 7 Standard Conditions for Operation in Service and for Installation...19
  • 8 Requirements for Construction and Operation...20
  • 9 Tests...33

Foreword

This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for

Standardization - Part 1.Rules for the Structure and Drafting of Standardizing Documents.

This Document used translation method to equivalently adopt IEC 62955.2018 Residual Direct

Current Detecting Device (RDC-DD) to be Used for Mode 3 Charging of Electric Vehicles.

The Chinese documents that have a consistent correspondence with the international documents

normatively cited in this document are as follows.

--- GB/T 2424.2-2005 Environment Tests for Electric and Electronic Products - Guidance

for Damp Heat Tests (IEC 60068-3-4.2001, IDT);

--- GB/T 4208-2017 Degrees of Protection Provided by Enclosure (IP Code) (IEC

60529.2013, IDT);

--- GB 4343.1-2018 Electromagnetic Compatibility Requirements for Household

Appliances, Electric Tools and Similar Apparatus - Part 1.Emission (CISPR 14-1.2011,

IDT);

--- GB/T 5169.10-2017 Fire Hazard Testing for Electric and Electronic Products - Part 10.

Glowing/Hot-Wire Based Test Methods - Glow-Wire Apparatus and Common Test

Procedure (IEC 60695-2-10.2013, IDT);

--- GB/T 16895 (all parts) Low-Voltage Electrical Installations [IEC 60364 (all parts)];

--- GB/T 16916.1-2014 Residual Current Operated Circuit-Breakers Without Integral

Overcurrent Protection for Household and Similar Uses (RCCB) - Part 1.General Rules

(IEC 61008-1.2012, MOD);

--- GB/T 16917.1-2014 Residual Current Operated Circuit-breakers with Integral

Overcurrent Protection for Household and Similar Uses (RCBOs) - Part 1.General Rules

(IEC 61009-1.2012, MOD);

--- GB/T 18499-2008 Residual Current Operated Protective Devices (RCD) for Household

and Similar Use - Electromagnetic Compatibility (IEC 61543.1995, IDT).

This Document made the following editorial modifications.

--- Move the informative references of IEC 60112 and IEC 60664-3 from Clause 2 to

Bibliography;

--- Supplement the cross-sectional area of the connectable copper conductors with rated

currents of 63A to 125A omitted in Table 7, which is consistent with the relevant

standards of residual current protection electrical apparatus;

--- Modify the error of "RDC-MD" into "RDC-DD" in 9.9.3;

--- Modify the error of "after the test of 9.10.3" into "after the test of 9.10.2" in 9.10.3;

--- Modify the error reference of "9.11.2.1 f) i)" into "9.11.2.1 f) 1)" in 9.11.2.1 f) 2);

---Modify the error of "5.1.1" into "5.1.1 in IEC 61543.1995+AMD1.2004" in Table 19 of

9.21.2;

--- Modify the error reference of "see J.3.6" into "see I.3.6" in I.1 of Annex I;

--- Modify the error of "Table 5" into "Table 7" in Table K.2;

--- Modify the error of "performance of RCCB under short-circuit conditions" into

"performance of RDC-PD under short-circuit conditions" in Table O.1.

Please note some contents of this Document may involve patents. The issuing agency of this

Document shall not assume the responsibility to identify these patents.

This Document was proposed by China Electrical Equipment Industry Association.

This Document shall be under the jurisdiction of National Technical Committee on Low-

Voltage Apparatus of Standardization Administration of China (SAC/TC 189).

Drafting organizations of this Document. Shanghai Electrical Apparatus Research Institute;

NOARK Electrics (Shanghai) Co., Ltd.; Shanghai Liangxin Electrical Co., Ltd.; Schneider

Electric (China) Co., Ltd. Shanghai Branch; Qingdao Topscomm Communication INC.;

Suzhou ELE Electrical Apparatus Manufacturing Co., Ltd.; Guizhou Taiyong-Changzheng

Technology Co., Ltd.; Shanghai TILVA Certification Technology Co., Ltd.; Shanghai Shengwei

Electronic & Technology Co., Ltd.; and Zhongshan Kaper Electrical Co., Ltd.

Chief drafting staffs of this Document. Wang Yuxuan, Li Renjie, Wang Bangle, Xu Jinchao, Ma

Feng, Wang Jianhua, Li Chengli, He Guibing, Dong Tianshuai, and Zou Jianhua.

Residual Direct Current Detecting Device (RDC-DD)

to be Used for Mode 3 Charging of Electric Vehicles

1 Scope

This Document specifies the classification, characteristics, marking, conditions of use and

installation, technical requirements for structure and operation, and corresponding tests of

residual direct current detecting device (RDC-DD) to be used for Mode 3 charging of electric

vehicles.

2 Normative References

The following documents are referred to in the text in such a way that some or all of their

content constitutes requirements of this document. For dated references, only the edition cited

applies. For undated references, the latest edition of the referenced document (including any

amendments) applies.

GB/T 2423.4-2008 Environmental Testing for Electric and Electronic Products - Part 2.

Test Method - Test Db. Damp Heat, Cyclic (12h+12h Cycle) (IEC 60068-2-30.2005,

IDT)

3 Terms, Definitions and Symbols

Monitoring device capable of 6 mA DC residual current detection and mechanical switching.

Protective device with integrated AC, pulsating DC and 6 mA DC detection, evaluation and

mechanical switching.

4 Classification of RDC-DD (RDC-MD, RDC-PD)

RDC-M-unit capable of 6mA DC residual current detection and evaluation mechanically

coupled to a separate protective device.

5 Characteristics of RDC-DDs

The rated operational voltage (hereafter referred to as "rated voltage") of an RDC-DD is the

value of voltage, assigned by the manufacturer, to which its performance is referred.

The rated impulse withstand voltage of an RDC-DD shall be equal to or higher than the standard

values of rated impulse withstand voltage given in Table 4.

6 Marking and Other Product Information

Due to physical reasons, for pulsating DC residual currents, only limited selectivity to upstream

type A or type F RCDs with a rated residual current of 30 mA can be achieved. For this reason,

related information shall be provided by the manufacturer.

7 Standard Conditions for Operation in Service and for Installation

RDC-DDs shall be installed in accordance with the manufacturer's instructions.

RDC-DDs complying with this document are intended for environment with pollution degree

2, i.e., normally, only non-conductive pollution occurs; occasionally, however, a temporary

conductivity caused by condensation may be expected.

8 Requirements for Construction and Operation

The protective conductor of the installation shall not become live in such a way that a dangerous

touch voltage is created when the RDC-DD is operated. A standing current in the PE up to the

limit of 1 mA is accepted with a touch voltage limited not exceeding dangerous levels according

to IEC 60364 series and IEC 60479 series of standards.

9 Tests

The RDC-DD is mounted individually according to manufacturer's instructions and in free air,

at an ambient temperature between 20°C and 25°C, unless otherwise specified, and is protected

against undue external heating or cooling.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 2423.4-2008 · IEC 60068

How to Buy GB/T 40820-2021

  1. 1Add to cart. Click the "Buy GB/T 40820-2021" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40820-2021

$1,490.00

$1,265.00for partners