Valid

GB/T 40067-2021Microstructure and defect determination of tungsten carbide powder (English PDF)

碳化钨粉末微观组织及缺陷检测方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 40067-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 21, 2021

Implementation date

December 1, 2021

Scope

GB/T 40067-2021 is the English-translated version of 碳化钨粉末微观组织及缺陷检测方法.

GB/T 40067-2021 describes how to examine the microstructure and defects of tungsten carbide powder with a scanning electron microscope. It applies to powders with a particle size of 0.1 µm to 0.5 µm.

The morphology is used to tell apart hard agglomerates, thick tungsten carbide particles, aggregates of grain inhibitors and impurities, and an X-ray energy dispersive spectrometer identifies the inhibitors and impurities; the equipment also includes an ultrasonic disperser and a conductive sample stage.

A thick particle is a single particle larger than five times the average particle size of the powder, and at least 20 fields of view are recommended. The test data give a representative microstructure picture and the number, size and category of the defects, and an informative annex shows typical pictures. It was issued on 21 May 2021 and has applied since 1 December 2021.

Found what you need?

Document preview — GB/T 40067-2021

National Standard of the People's Republic of China

ICS
77.160
Classification
H 24

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative References4
  • 3 Terms and Definitions4
  • 4 Principle4
  • 5 Instruments and Equipment4
  • 6 Sample5
  • 7 Test Procedures5
  • 8 Processing of Test Data6
  • 9 Test Report6
  • Appendix A (informative) Pictures of Microstructure and Typical Defects of Tungsten Carbide Powder8

1 Scope

This Standard specifies the scanning electron microscope detection method for microstructure observation and defect analysis of tungsten carbide powder.

This Standard is applicable to the scanning electron microscope detection of the microstructure and defect of tungsten carbide power with a particle size of 0.1 µm ~ 0.5 µm.

2 Normative References

This document does not have normative references.

3 Terms and Definitions

There are no terms and definitions that need to be defined in this document.

4 Principle

Use a scanning electron microscope to observe the morphology of the prepared tungsten carbide powder. From the morphology, distinguish the hard agglomeration of tungsten carbide powder, the thick tungsten carbide powder, the aggregation of grain inhibitors and the impurities. Through an X-ray energy dispersive spectrometer, determine the grain inhibitors and the impurities.

5 Instruments and Equipment

5.1 Scanning electron microscope.

5.2 X-ray energy dispersive spectrometer.

5.3 Ultrasonic disperser.

5.4 Sample stage: the sample stage shall be conductive; the end surface shall be smooth, flat and clean. […]

7 Test Procedures

NOTE: the thick tungsten carbide powder is a single tungsten carbide particle with a size greater than 5 times the average particle size of the powder. The average particle size of the powder can be Fischer particle size, laser particle size or the average particle size of the powder converted from specific surface area.

7.2.6 If a structure with significantly different color and shape from that of the matrix tungsten carbide powder is found, then, use the X-ray energy dispersive spectrometer to perform elemental analysis on the observed structure, so as to determine whether it is an aggregation of grain inhibitor or impurity. See Figure A.4, Figure A.5, Figure A.6 and Figure A.7.

7.2.7 In order to ensure that the observed tungsten carbide powder is representative, it is recommended to browse at least 20 fields of view.

8 Processing of Test Data

8.1 Microstructure

Provide a representative picture of the microstructure, see Figure A.1.

8.2 Defects

8.2.1 Provide the number and size of the hard agglomeration of tungsten carbide powder.

8.2.2 Provide the number and size of the thick tungsten carbide powder.

8.2.3 Provide the category of the agglomeration of grain inhibitor or the impurity.

9 Test Report

The test report shall include the following contents:

a) Serial No. of this document;

b) Necessary instruction for sample identification;

c) Number of fields of view for detection;

d) Picture of the microstructure of tungsten carbide powder;

e) Type, size and number of defects;

f) Other operations not specified or optional in this document; […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 40067-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40067-2021

$150.00