GB/T 39873-2021 is the English-translated version of 消毒剂中季铵盐的测定 液相色谱-串联质谱法.

GB/T 39873-2021 is the Chinese method for determining quaternary ammonium salts in a disinfectant by liquid chromatography-tandem mass spectrometry. It gives the reagents and materials, the instruments and equipment, the determination procedure, the calculation of the results, the precision and the limits of detection and quantification.

It applies to dodecyl dimethyl benzyl ammonium chloride, tetradecyl dimethyl benzyl ammonium chloride and the other quaternary ammonium compounds listed, the active ingredients of most surface disinfectants.

Disinfectant makers and control laboratories use it. Issued on 9 March 2021, it has applied since 1 October 2021.

Found what you need?

Document preview — GB/T 39873-2021

National Standard of the People's Republic of China

ICS
11.080.20
Classification
C 50

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principle
  • 5 Reagents and materials
  • 6 Apparatus and equipment
  • 7 Measurement procedure
  • 8 Result calculation
  • 9 Precision
  • 10 Detection limit and quantification limit

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.

1 Scope

This document specifies the reagents and materials, instruments and equipment, determination procedures, and results for the determination of quaternary ammonium salts in disinfectants by liquid chromatography-tandem mass spectrometry. Result calculation, precision, detection limit and quantification limit.

This document applies to dodecyl dimethyl benzyl ammonium chloride (C12-BAC), tetradecyl dimethyl benzyl ammonium chloride (C14- BAC), Cetyl Dimethyl Benzyl Ammonium Chloride (C16-BAC), Didecyl Dimethyl Ammonium Chloride (DDAC), Dodecyl Trimethyl Ammonium Bromide (DTAB), determination of dodecyldimethyl-2-phenoxy-ethylammonium bromide (EDDAB).

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 6682 Analytical laboratory water specifications and test methods

3 Terms and definitions

There are no terms and definitions that need to be defined in this document.

4 Principle

The sample was ultrasonically extracted with a methanol solution containing 0.5% formic acid, vortexed, and centrifuged, and filtered with a 0.22 µm organic filter membrane. The test solution was subjected to liquid chromatography- Tandem mass spectrometry determination, retention time and relative ion pair abundance qualitative, external standard method quantification.

5 Reagents and materials

Unless otherwise specified, use only chromatographically pure reagents.

5.3 0.5% formic acid in methanol. pipette 5mL formic acid in a 1000mL volumetric flask, and methanol to a constant volume.

5.4 0.1% formic acid solution. pipette 1mL formic acid in a 1000mL volumetric flask and dilute to volume with water.

5.5 Quaternary ammonium salt standards. dodecyl dimethyl benzyl ammonium chloride, tetradecyl dimethyl benzyl ammonium chloride, cetyl dimethyl benzyl chloride Ammonium chloride, didecyl dimethyl ammonium chloride, dodecyl trimethyl ammonium bromide, dodecyl dimethyl-2-phenoxy-ethyl ammonium bromide, the purity is not small At 99.0%, see Appendix A for CAS number, molecular formula, and relative molecular mass.

5.6 Quaternary ammonium salt standard stock solution, 100mg/L. accurately weigh 10mg of each quaternary ammonium salt standard substance (5.5), accurate to 0.1mg, in 100mL In the volumetric flask, dissolve and dilute to the mark with 0.5% formic acid in methanol (5.3).

5.7 Standard working solution. Use 0.5% formic acid in methanol (5.3) to prepare a series of mass concentrations of the above standard stock solution (5.6) respectively.

5.2 Acetonitrile (CH3CN)

The quaternary ammonium salt standard stock solution is stored at -18°C, and the storage period is 6 months.

The standard working solutions of 0.050mg/L, 0.100mg/L, 0.200mg/L, 0.500mg/L, 1.00mg/L are currently prepared.

6 Apparatus and equipment

6.1 Liquid chromatography-tandem mass spectrometer, power distribution spray ion source.

6.2 Analytical balance, the sensitivity is 0.001g and 0.0001g.

6.4 Centrifuge, the speed is greater than or equal to 8000r/min.

7 Measurement procedure

7.1 Sample processing

Weigh 1g of sample (accurate to 0.001g), sample 1mL of liquid sample, add 70mL of 0.5% formic acid in a 100mL volumetric flask Methanol solution (5.3), vortex mixing for 1 min, ultrasonic extraction for 20 min, dilute to volume with 0.5% formic acid in methanol (5.3). Take part The sample solution was centrifuged at 8000r/min for 10min, filtered through a 0.22µm filter membrane, and the filtrate was used as the sample solution to be tested for later use. If the content of the tested component is higher High, it can be diluted with 0.5% formic acid in methanol (5.3), filtered through a 0.22µm filter membrane, and the filtrate used as the sample solution to be tested for later use.

7.2 Measurement conditions

7.2.1 Reference conditions for liquid chromatography

Depending on the equipment, the measurement conditions may be different. The following measurement conditions have been confirmed to be feasible.

a) Chromatographic column. C18, 50mm×2.1mm (particle size 1.7µm), or other equivalent performance;

b) Flow rate. 0.3mL/min;

c) Column temperature. 35°C;

d) Injection volume. 1µL;

e) Mobile phase. solvent A. acetonitrile (5.2), solvent B. 0.1% formic acid solution (5.4);

f) The gradient elution conditions of liquid chromatography are shown in Table 1.

7.2.2 Reference conditions for mass spectrometry

Depending on the equipment, the measurement conditions may be different. The following measurement conditions have been confirmed to be feasible.

a) Ionization method. electrospray ionization, positive ion;

b) Detection method. multi-reaction monitoring;

c) Capillary voltage. 3000V;

d) Atomizing gas temperature. 450°C;

e) Atomizing gas flow rate. 800L/h;

f) Cone air flow rate. 150L/h;

g) Ion source temperature. 150°C.

See Table 2 for monitoring ion pair, collision energy and cone voltage.

7.3 Drawing standard working curve

According to the measurement conditions of 7.2, draw 1µL of standard working solution (5.7) respectively and measure the concentration from low to high, and quantify the ion pair The peak area is the ordinate, the corresponding solution concentration is the abscissa, and the regression equation of the standard curve is obtained.

Refer to Appendix B for the liquid chromatography-tandem mass spectrometry chromatogram of the reference material quaternary ammonium salt.

7.4 Determination of liquid chromatography-tandem mass spectrometry

7.4.1 Qualitative determination

When the sample is measured under the same test conditions, the retention time of the detected chromatographic peak is compared with the standard sample, and the variation range is Within ±2.5%; and in the sample mass spectrum, the selected ion pairs appear, and the selected relative ion pair abundance is equivalent to the concentration Compared with the standard solution, the allowable relative deviation does not exceed the range specified in Table 3, then the target analyte can be qualitatively confirmed.

7.4.2 Quantitative determination

The liquid chromatography-tandem mass spectrometry in this document adopts the external standard-calibration curve method for quantitative determination, and the response of the tested components in the tested samples should be ensured.

The response value is within the range of the standard curve.

7.5 Blank test

Except that no sample is added, it shall be implemented in accordance with the provisions of 7.1 to 7.4.

8 Result calculation

The calculation of the content of each quaternary ammonium salt in the sample is calculated according to formula (1).

9 Precision

In the same laboratory, the same operator uses the same equipment, according to the same test method, and compares the same object under test in a short period of time.

The absolute difference between the two independent test results obtained by independent tests shall not be greater than 10% of the arithmetic mean of the two measured values.

10 Detection limit and quantification limit

When the sampling volume is 1g and the constant volume is 100mL, the detection limit is 0.003g/kg, and the quantification limit is 0.01g/kg.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 39873-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
18 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39873-2021

$135.00